METODEAFPRØVNING AF PASSIVE DIFFUSIONSOPSAMLERE ...
METODEAFPRØVNING AF PASSIVE DIFFUSIONSOPSAMLERE ...
METODEAFPRØVNING AF PASSIVE DIFFUSIONSOPSAMLERE ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
6XPPDU\<br />
Measurements of atmospheric ammonia concentrations by two types of<br />
passive diffusion tube samplers (ALPHA and Radiello) have been compared<br />
to active measurements obtained by the denuder method. The<br />
comparison was made at several locations over a one year period, covering<br />
different concentrations levels and seasons. The passive diffusions<br />
tube samples were found suitable for fortnight to monthly sampling.<br />
Both types of passive diffusion tubes showed a small systematic overestimation<br />
of the ammonia concentration compared to the denuder tubes<br />
and therefore demand a correction. The precision is good and both types<br />
of tubes are suitable for measuring local gradients. Since the passive diffusion<br />
tubes are independent of power supply, they are very suitable for<br />
monitoring purposes.<br />
7