OPERATION AND USE<br />
Within three seconds from the power-up the display<br />
illuminates a dash (self-check phase).<br />
The following indications depend on the operating<br />
status of the control unit and from the menu level<br />
activated by the operator<br />
D<br />
1. STANDBY. Pressing button ‘D’ allows you to put<br />
the cabinet on standby, this then excludes all<br />
outputs with the exception of the lighting control<br />
(either manual or door controlled). ‘OFF’ is then<br />
displayed on the controller. When working on the<br />
cabinet, always unplug the unit from the socket or<br />
isolate from mains prior to starting work on the unit.<br />
2. NORMAL. During normal operation, the display<br />
shows the internal air temperature<br />
3. DEFROST. If the control unit is performing<br />
defrost, dEF will be shown on the display.<br />
The unit will have a defrost period every 12 (C-units)<br />
or 6 (M and F-units) hours.<br />
English<br />
A C<br />
4. MANUAL DEFROST. In the scenario that a door<br />
has been left open and the evaporator coil has iced<br />
up and manual defrost can be initiated. This can be<br />
started from the info menu by selecting dF by<br />
pressing button “A” first and then “A” and “C”<br />
simultaneously. Text dEF will be shown on the<br />
display. Manual defrost resets the defrost counter,<br />
and the unit continues to operate automatically<br />
after manual defrost.<br />
EVAPORATION OF CONDENSATE WATER<br />
The water developed during defrosting is led to the<br />
condensate tray where the water evaporates<br />
automatically.<br />
B C D<br />
5. ADJUSTING THE TEMPERATURE. Temperature<br />
setpoint can be checked by pressing button “B”.<br />
If higher temperature is required, keep button “B”<br />
pressed and simultaneously press the button “C”.<br />
If lower temperature is required, keep button “B”<br />
pressed and simultaneously press the button “D”.<br />
11