Page 18 / Catalog K-1, <strong>ZoomLock</strong> <strong>Braze</strong>-<strong>Free</strong> <strong>Fittings</strong><br />
Helium Leak Test Report<br />
1250 Arthur E Adams Dr., Columbus, OH 43221 LAB SERVICES<br />
Customer: Marmon Refrigeration Technologies<br />
Helium Leak Test Report<br />
page 2 of 2<br />
Project No.: 12866CSL-01<br />
Equipment: Veeco MS-40 Date Reported: January 10, 2013<br />
Project Engineer: Jim Busch<br />
Principal Tech: Barb Christel<br />
Figure 1. Test Set-up<br />
Results: The maximum leak rate of all connections is summarized in Table 2. The maximum leak rate<br />
detected was 5.40E-09 std.cc/sec.<br />
Table 2. Maximum Leak Rate per Lot<br />
Tube O.D.<br />
(in)<br />
Maximum Helium Leak<br />
std.cc/sec<br />
0.250 4.00E-10<br />
0.313 6.10E-10<br />
0.375 1.30E-09<br />
0.750 5.20E-09<br />
0.875 5.40E-09<br />
1.125 3.00E-10<br />
Reported by: Brad Nagy<br />