13 SEER / R-410A - Goodman
13 SEER / R-410A - Goodman
13 SEER / R-410A - Goodman
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
EspEcificacionEs dEl producto<br />
daToS eXTendidoS SoBre refriGeraCión — GSX<strong>13</strong>0361a* / Ca*f4860*6**<br />
Temperatura ambiente exterior<br />
65 ºF 75 ºF 85 ºF 95 ºF 105 ºF 115 ºF<br />
Temperatura de bulbo húmedo interior de entrada<br />
IDB Flujo de aire 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71<br />
MBh 34.3 35.5 38.9 - 33.5 34.7 38.0 - 32.7 33.9 37.1 - 31.9 33.1 36.2 - 30.3 31.4 34.4 - 28.1 29.1 31.9 -<br />
S/T 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48 -<br />
∆T 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 10 -<br />
<strong>13</strong>50 kW 2.45 2.50 2.58 - 2.63 2.69 2.77 - 2.79 2.85 2.94 - 2.94 3.00 3.09 - 3.06 3.12 3.22 - 3.16 3.23 3.33 -<br />
Amperios 8.8 9.0 9.3 - 9.6 9.8 10.1 - 10.4 10.7 11.0 - 11.1 11.4 11.8 - 11.9 12.2 12.6 - 12.6 12.9 <strong>13</strong>.4 -<br />
PR alta 234 252 266 - 262 282 298 - 298 321 339 - 340 366 386 - 382 411 434 - 422 454 480 -<br />
PR baja 106 112 123 - 112 119 <strong>13</strong>0 - 116 123 <strong>13</strong>5 - 122 <strong>13</strong>0 142 - 128 <strong>13</strong>6 148 - <strong>13</strong>2 141 153 -<br />
MBh 33.3 34.5 37.8 - 32.5 33.7 36.9 - 31.7 32.9 36.1 - 31.0 32.1 35.2 - 29.4 30.5 33.4 - 27.3 28.3 31.0 -<br />
S/T 0.69 0.58 0.40 - 0.71 0.60 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.79 0.66 0.45 - 0.79 0.66 0.46 -<br />
∆T 18 15 12 - 18 15 12 - 18 15 12 - 18 16 12 - 18 15 12 - 17 14 11 -<br />
70 1200 kW 2.43 2.48 2.56 - 2.61 2.67 2.75 - 2.77 2.83 2.92 - 2.91 2.97 3.07 - 3.03 3.10 3.20 - 3.<strong>13</strong> 3.20 3.31 -<br />
Amperios 8.7 9.0 9.3 - 9.5 9.7 10.0 - 10.3 10.6 10.9 - 11.0 11.3 11.7 - 11.8 12.1 12.5 - 12.5 12.8 <strong>13</strong>.2 -<br />
PR alta 231 249 263 - 260 279 295 - 295 318 336 - 336 362 382 - 378 407 430 - 418 450 475 -<br />
PR baja 105 111 122 - 111 118 128 - 115 122 <strong>13</strong>3 - 121 128 140 - 126 <strong>13</strong>5 147 - <strong>13</strong>1 <strong>13</strong>9 152 -<br />
MBh 30.7 31.9 34.9 - 30.0 31.1 34.1 - 29.3 30.4 33.3 - 28.6 29.6 32.5 - 27.2 28.2 30.8 - 25.2 26.1 28.6 -<br />
S/T 0.67 0.56 0.38 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.76 0.64 0.44 -<br />
∆T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -<br />
1050 kW 2.38 2.43 2.50 - 2.55 2.61 2.69 - 2.71 2.76 2.85 - 2.84 2.90 2.99 - 2.96 3.02 3.12 - 3.06 3.12 3.22 -<br />
Amperios 8.5 8.7 9.0 - 9.2 9.4 9.7 - 10.0 10.3 10.6 - 10.7 11.0 11.4 - 11.4 11.7 12.1 - 12.1 12.4 12.9 -<br />
PR alta 224 242 255 - 252 271 286 - 286 308 326 - 326 351 371 - 367 395 417 - 406 436 461 -<br />
PR baja 101 108 118 - 107 114 125 - 111 119 129 - 117 125 <strong>13</strong>6 - 123 <strong>13</strong>0 142 - 127 <strong>13</strong>5 147 -<br />
MBh 34.9 35.9 38.9 41.7 34.1 35.1 38.0 40.7 33.3 34.2 37.1 39.8 32.4 33.4 36.2 38.8 30.8 31.7 34.4 36.9 28.6 29.4 31.8 34.2<br />
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.63 0.41 0.94 0.84 0.64 0.41<br />
∆T 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 18 17 14 10<br />
kW 2.47 2.52 2.60 2.68 2.66 2.71 2.79 2.88 2.82 2.88 2.97 3.06 2.96 3.02 3.12 3.22 3.08 3.15 3.25 3.36 3.19 3.26 3.36 3.47<br />
Amperios 8.9 9.1 9.4 9.8 9.6 9.9 10.2 10.6 10.5 10.8 11.1 11.6 11.3 11.5 11.9 12.4 12.0 12.3 12.7 <strong>13</strong>.2 12.7 <strong>13</strong>.0 <strong>13</strong>.5 14.0<br />
PR alta 236 254 268 280 265 285 301 314 301 324 342 357 343 369 390 407 386 415 439 458 427 459 485 506<br />
PR baja 107 114 124 <strong>13</strong>2 1<strong>13</strong> 120 <strong>13</strong>1 <strong>13</strong>9 117 125 <strong>13</strong>6 145 123 <strong>13</strong>1 143 152 129 <strong>13</strong>7 150 160 <strong>13</strong>3 142 155 165<br />
MBh 33.9 34.9 37.7 40.5 33.1 34.1 36.9 39.6 32.3 33.2 36.0 38.6 31.5 32.4 35.1 37.7 29.9 30.8 33.3 35.8 27.7 28.5 30.9 33.2<br />
S/T 0.78 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.75 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.81 0.61 0.39<br />
∆T 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 20 19 15 11 19 18 14 10<br />
kW 2.45 2.50 2.58 2.66 2.63 2.69 2.77 2.86 2.79 2.85 2.94 3.04 2.94 3.00 3.09 3.20 3.06 3.12 3.22 3.33 3.16 3.23 3.33 3.44<br />
Amperios 8.8 9.0 9.3 9.7 9.6 9.8 10.1 10.5 10.4 10.7 11.0 11.5 11.1 11.4 11.8 12.3 11.9 12.2 12.6 <strong>13</strong>.1 12.6 12.9 <strong>13</strong>.4 <strong>13</strong>.9<br />
PR alta 234 252 266 277 262 282 298 311 298 321 339 354 340 366 386 403 382 411 434 453 422 454 480 501<br />
PR baja 106 112 123 <strong>13</strong>1 112 119 <strong>13</strong>0 <strong>13</strong>8 116 123 <strong>13</strong>5 144 122 <strong>13</strong>0 142 151 128 <strong>13</strong>6 148 158 <strong>13</strong>2 141 153 163<br />
MBh 31.3 32.2 34.8 37.4 30.5 31.4 34.0 36.5 29.8 30.7 33.2 35.6 29.1 29.9 32.4 34.8 27.6 28.4 30.8 33.0 25.6 26.3 28.5 30.6<br />
S/T 0.76 0.68 0.51 0.33 0.78 0.70 0.53 0.34 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.87 0.78 0.59 0.38<br />
∆T 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10<br />
kW 2.40 2.45 2.52 2.60 2.57 2.63 2.71 2.79 2.73 2.79 2.87 2.96 2.87 2.93 3.02 3.12 2.98 3.05 3.14 3.25 3.08 3.15 3.25 3.36<br />
Amperios 8.6 8.8 9.1 9.4 9.3 9.5 9.8 10.2 10.1 10.4 10.7 11.1 10.8 11.1 11.5 11.9 11.5 11.8 12.2 12.7 12.2 12.6 <strong>13</strong>.0 <strong>13</strong>.5<br />
PR alta 227 244 258 269 254 274 289 302 289 311 329 343 330 355 375 391 371 399 421 439 410 441 466 486<br />
PR baja 103 109 119 127 108 115 126 <strong>13</strong>4 1<strong>13</strong> 120 <strong>13</strong>1 <strong>13</strong>9 118 126 <strong>13</strong>7 146 124 <strong>13</strong>2 144 153 128 <strong>13</strong>6 149 159<br />
14 www.goodmanmfg.com SS-GSX<strong>13</strong>-SP<br />
<strong>13</strong>50<br />
1200<br />
75<br />
1050<br />
IDB: Temperatura de bulbo seco interior de entrada El área sombreada refleja las condiciones ACCA (TVA) Amperios = amperios de la unidad exterior (comp.+ventilador)<br />
Las presiones altas y bajas se miden en las válvulas de servicio de líquido y succión. kW = Alimentación total del sistema