INVERTEC PC208 & PC210 - Lincoln Electric - documentations
INVERTEC PC208 & PC210 - Lincoln Electric - documentations
INVERTEC PC208 & PC210 - Lincoln Electric - documentations
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Technical Specifications<br />
Input Voltage<br />
230 V ±10%<br />
Single Phase<br />
INPUT<br />
Input Power at Rated Output<br />
2 kW @ 100% Duty Cycle<br />
2.5 kW @ 60% Duty Cycle<br />
3 kW @ 35% Duty Cycle<br />
RATED OUTPUT AT 40°C<br />
Output Current<br />
Frequency<br />
50Hz<br />
Duty Cycle<br />
Output Voltage<br />
(Based on a 10 min. period)<br />
100%<br />
15 A<br />
86 Vdc<br />
60%<br />
20 A<br />
88 Vdc<br />
35%<br />
25 A<br />
90 Vdc<br />
OUTPUT RANGE<br />
Cutting Current Range Maximum Open Circuit Voltage Pilot Arc Current<br />
10 - 25 A 500 Vdc 10 A<br />
EXTERNAL INLET COMPRESSED AIR<br />
Required Inlet Flow Rate<br />
Required Inlet Pressure<br />
<strong>PC210</strong> 80 ±20% l/min @ 5.0bar <strong>PC210</strong> 6.0bar - 7.5bar<br />
RECOMMENDED INPUT CABLE AND FUSE SIZES<br />
Fuse (delayed) or Circuit Breaker (“D”<br />
Type of Plug<br />
Input Power Cable<br />
characteristic) Size<br />
(Included with Machine)<br />
16 A<br />
SCHUKO 16A / 250V or<br />
AUSTRALIAN 15A / 250V<br />
3 Conductor, 1.5 mm 2<br />
PHYSICAL DIMENSIONS<br />
Height Width Length<br />
Weight<br />
(case only,without torch)<br />
385 mm 215 mm 480 mm 18 – 18.5 kg<br />
Operating Temperature<br />
-10°C to +40°C<br />
Storage Temperature<br />
-10°C to +40°C<br />
A-6