ECO-CCE - AstralPool
ECO-CCE - AstralPool
ECO-CCE - AstralPool
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>ECO</strong> COUNTER-CURRENT EQUIPMENT<br />
king glands (37) in place gently pull the two<br />
conduits so that thay do not remain bent inside<br />
the case. Lead the control conduit (22) to the<br />
control cabinet and set it up inside the wall conduit.<br />
Put the air inlet valve (20) onto the end of<br />
the suction tube (14), its design allowing it to be<br />
fixed onto the wall above the water level.<br />
If you cannot get to the back end of the housing<br />
case then the suction and control conduits (14)<br />
and (22) must be sealed from inside the housing<br />
case. Put the two packing glands PG16<br />
(37) with the seals onto the conduits and pass<br />
them through the packing gland holes and protection<br />
tubes (assembled before-hand in the<br />
housing case. See (Fig. 3). Put the return inlet<br />
unit next to the return pipe (31) and before<br />
fixing the packing glands slide through the conduits,<br />
leaving the least possible length free to<br />
fix the packing glands, so that when you introduce<br />
the return inlet unit fully into the housing<br />
case the conduits (14) and (22) don't bend.<br />
Lead the control conduit (22) to the control<br />
cabinet and assemble it inside the wall conduit.<br />
Put the valve (20) onto the end of the suction<br />
tube (14).<br />
The propulsion outlet unit is situated right<br />
against the pool wall, fix it in place using 4<br />
screws depending on the thickness of the surface<br />
finish.The assembly allows a tolerance of<br />
0-70 mm.<br />
Glue the PVC piping from the flange connection<br />
to the siting of the pump, the installation of<br />
valves is recommended here for future maintainance<br />
operations.<br />
The pump is fixed onto the floor on cushions<br />
and in a horitzontal position. The 2 outlets of<br />
the pump will be connected to the tubes<br />
coming from the housing case.<br />
2c. Assembly of the unit in liner pools<br />
For this installation, a set of fittings composed<br />
(48), of the flange and sealing gaskets is required.<br />
Installation of the unit is the same as described<br />
beforehand.<br />
2d. Installation of the unit in pre-fabricated<br />
pools<br />
For installation of the unit in pre-fab. pools,<br />
a set of fittings (48), composed of a flange<br />
and sealing gaskets is required. For<br />
assembly instructions procede as described<br />
beforehand.<br />
3. ELECTRICAL INSTALLATION<br />
The electrical installation must be made in<br />
accordance with the regulations concerning<br />
electrical protection in force in each country.<br />
The installation should be made by an<br />
authorised installer. Check that the voltage<br />
coincides with the specifications plaque of the<br />
pump. Use a power cable of 5x4 mm². for the<br />
pump 3,3 kW., of 5x2,5 mm². for the pump 2,6<br />
kW. and 3x2,5 mm². for the 1,5 kW. pump. For<br />
protection, install 16 amp. fuses, and without<br />
fail a circuit breaker of 25/0.03 A. (30 mA).<br />
The control cabinet comes with the following<br />
components: A thermal relay to ensure the protection<br />
of the motor, which must be correctly<br />
regulated, according to the current consump-<br />
5<br />
ENGLISH<br />
<strong>ECO</strong> <strong>CCE</strong>