21.01.2015 Views

7. Tecnología de refrigeración y calefacción - Serviquimia SL

7. Tecnología de refrigeración y calefacción - Serviquimia SL

7. Tecnología de refrigeración y calefacción - Serviquimia SL

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>7.</strong> Tecnología <strong>de</strong> refrigeración y calefacción<br />

Calentar/Baños <strong>de</strong> agua<br />

GENERAL CATALOGUE 2010/11<br />

1<br />

722<br />

1<br />

Shaking Water Bath 1070, Thermolab ®<br />

The Quadrothermal Shaking Water Bath 1070 with reciprocating motion is equipped<br />

GFL<br />

with four separate tanks, in which different sample vessels can be heated, in<strong>de</strong>pen<strong>de</strong>ntly<br />

of each other. It is universally applicable for use in routine, research and specialised laboratories for all temperature<strong>de</strong>pen<strong>de</strong>nt<br />

reactions, e.g. for incubations of reagents and solutions, Enzyme-Immuno-Essays, Western-Blots, Reverse<br />

Dot Blots, for hybridisations at four different temperatures, for stringent washing processes with variable<br />

temperatures, Restriction Enzyme Digestions, Proteinase-K Digestions, DNA Elution, T 7 Sequenase Sequencing, for<br />

thawing processes and incubations of cultures or for polymerase chain reactions (PCR). Microprocessor controlled<br />

temperature regulation. Temperature constancy: ±0.1°C temporal. Temperature range from approx. 5°C above<br />

ambient to +99.9°C. Temperature display and setting digitally via LED display. Electronic monitoring of the<br />

temperature controller. Electronic over-temperature cut-out applies at 4°C above set temperature and<br />

electromechanical at >130°C. Maintenance-free and durable shaking <strong>de</strong>vice, electronically controlled and continuously<br />

settable shaking motion, with soft-start.<br />

Insulating, double-walled lid - no dripping back of con<strong>de</strong>nsate into the vessels. Bath interior and shaking rack are in<br />

stainless steel. Height-adjustable, sample hol<strong>de</strong>r in each of the four tanks. With the use of optional racks or directly<br />

on the sample hol<strong>de</strong>rs, all kinds of vessels from ìl to ml used in laboratories can be held.<br />

2<br />

Technical Specification:<br />

External dimensions (WxDxH):<br />

625 x 556 x 270mm<br />

Usable internal dimensions per tank<br />

175 x 175 x 100mm<br />

(sample hol<strong>de</strong>r) (WxDxH):<br />

128 x 128mm<br />

Usable bath height:<br />

80mm<br />

Sample hol<strong>de</strong>r, height-adjustable:<br />

32mm<br />

Temperature range:<br />

from approximately 5°C above ambient temperature to 99.9°C<br />

Temperature control:<br />

Electronic<br />

microprocessor-controlled with proportional-plus-integral control (PI)<br />

Temperature accuracy:<br />

±0.1°C<br />

Temperature display:<br />

Digital LED<br />

Temperature adjustment:<br />

Digital LED<br />

Overtemperature cut-out: electronic 4°C above set temperature, and electro-mechanical ><br />

130°C<br />

Shaking motion:<br />

Reciprocating, can be switched on/off<br />

Shaking frequency:<br />

2 to 50 strokes/min.<br />

Shaking speed adjustment:<br />

Variable<br />

Shaking amplitu<strong>de</strong>:<br />

22mm<br />

Supply requirement:<br />

230V 50/60Hz, 1.3 kW<br />

Net/gross weight:<br />

28/36kg<br />

Type PK Cat. No.<br />

1070 1 9.905 980<br />

2 Type 1070<br />

Racks for test tubes and microtubes in Shaking Water Bath 1070.<br />

GFL<br />

Type Description For PK Cat. No.<br />

1710<br />

1711<br />

1712<br />

With 7 apertures 31mm dia.<br />

With 19 apertures 17mm dia.<br />

With 32 apertures 12mm dia.<br />

Test tubes 50 ml<br />

Test tubes 15ml<br />

Reaction vessels 1.5 to 2.0 ml<br />

1<br />

1<br />

1<br />

9.905 987<br />

9.905 988<br />

9.905 989<br />

710<br />

Salvo error u omisión