21.07.2015 Views

Hinnasto 2013 (PDF 7.4Mt) - Oy Combi Cool Ab

Hinnasto 2013 (PDF 7.4Mt) - Oy Combi Cool Ab

Hinnasto 2013 (PDF 7.4Mt) - Oy Combi Cool Ab

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Oy</strong> <strong>Combi</strong> <strong>Cool</strong> <strong>Ab</strong> <strong>Hinnasto</strong> elokuu <strong>2013</strong>MitoitustaulukotSivu 179Capacity (continued)R410ACapacity in kW for range N and K, opening superheat OS = 4 KType RatedPressure drop across the valve Δp barPressure drop across the valve Δp barand rated capacitycapacity [kW] 3 6 9 12 15 18 21 24 3 6 9 12 15 18 21 24Evaporating temperature +15°CEvaporating temperature +10°CTGEL 3.5TGEL 4.5TGEL 6.5TGEL 9TGEL 13TGEL 15TGEL 19TGEL 23TGEL 31TGEL 35TGEL 46TGEL 3.5TGEL 4.5TGEL 6.5TGEL 9TGEL 13TGEL 15TGEL 19TGEL 23TGEL 31TGEL 35TGEL 46121624324554687911012516112162432455468791101251618.711.817.422.729.642.754.960.992.5104.5123.88.211.216.622.029.440.451.959.087.399.2118.511.315.322.429.338.754.269.378.2115.5130.6159.212.717.225.132843.959.775.987.0125.6141.8177.513.518.326.534.647.062.178.691.1128.9145.5186.413.818.626.935.148.262.078.191.4127.1143.5187.713.918.626.834.848.660.776.389.9123.2139.0185.113.718.326.334.148.258.773.486.8117.7132.7179.613.317.825.432.947.156.069.782.7111.2125.3171.88.511.617.022.529.641.753.660.390.3102.3121.711.014.921.928.938.652.767.476.9112.3127.1155.612.416.824.532.243.757.973.685.1121.6137.6172.713.117.725.733.746.459.775.688.1123.7139.9179.513.318.026.134.147.659.675.088.1121.8137.7180.1Evaporating temperature +5°C Evaporating temperature 0°C10.614.421.328.238.150.864.974.8108.0122.6150.511.916.223.731.343.055.670.682.1116.4132.0166.012.516.924.732.645.456.971.984.1117.5133.0170.712.817.225.032.946.556.671.383.6115.4130.6170.412.817.224.932.646.855.469.481.3111.6126.2166.712.616.924.431.946.453.666.877.9106.6120.4160.612.316.523.630.845.551.263.674.4100.8113.8152.67.910.816.021.428.938.749.757.283.795.2114.210.113.920.527.337.448.561.971.9103.0117.0144.011.315.422.630.041.852.566.777.9109.8124.7156.711.816.023.531.143.953.667.779.2110.4125.2160.112.116.323.731.444.953.367.078.2108.3122.7158.913.418.026.033.947.958.473.286.2117.9133.2177.012.116.323.631.145.252.165.276.4104.5118.3154.513.217.725.433.147.656.470.482.9112.7127.2171.311.916.023.130.444.850.362.773.899.8112.8147.912.917.224.632.046.653.967.078.7106.5120.1163.411.715.622.429.343.948.159.770.494.3106.5139.7Correction for subcooling Δt subThe evaporator capacity used must becorrected if the subcooling deviates from 4 K.The corrected capacity can be obtained bydividing the required evaporator capacity bythe correction factor given across, and thenselecting from the tables.Δt sub4 °K 10 °K 15 °K 20 °K 25 °K 30 °K 35 °K 40 °K 45 °K 50 °KCorrectionfactor1.00 1.08 1.14 1.20 1.26 1.31 1.37 1.43 1.48 1.54Note: Flash gas can form if subcooling is too low.Pressure controls for fluorinated refrigerantsPressure Type Regulatingrange[bar]Low KP 1 0.2 - 7.5Low pressure (LP) High pressure (HP) ResetDifferential∆p[bar]Regulatingrange[bar]Differential∆p[bar]LowpressureLPHighpressureHPContactsystem1/4 in.6 mmflareCode no.– 0.7 - 4 - - Aut. -060-110166 3 ) 060-111266 3 ) 060-111066 3 )Low KP 1 –0.2 - 7.5 0.7 - 4 - - Aut. - 060-114166 1 ) 3 ) - -Low KP 1 – 0.9 - 7 0.7 - - Man. - 060-110366 060-111166 060-110966SPDTLow KP 2 –0.2 - 5 0.4 - 1.5 - - Aut. - 060-112066 3 ) - 060-112366 3 )High KP 5 - - 8 - 32 1.8 - 6.0 - Aut. 060-117166 3 ) 060-117966 3 ) 060-117766 3 )High KP 5 - - 8 - 32 3 - Man. 060-117366 060-118066 060-117866Dual KP 15 –0.2 - 7.5 0.7 - 4 8 - 32 4 Aut. Aut.060-124166 3 ) 060-125466 3 ) -Dual KP 15 –0.2 - 7.5 0.7 - 4 8 - 32 4 Aut. Man. SPDT + 060-124366 - -Dual KP 15 – 0.2 - 7.5 0.7 - 4 8 - 32 4 Aut. Man. LP 060-114866 1 ) - -Dual KP 15 –0.9 - 7 0.7 8 - 32 4 Man. Man. signal 060-124566 - -Dual KP 15 –0.9 - 7 0.7 8 - 32 4 Conv. 2 ) Conv. 2 ) 060-126166 - -Dual KP 15 –0.2 - 7.5 0.7 - 4 8 - 32 4 Aut. Aut. SPDT + 060-126566 3 ) 060-129966 3 ) -Dual KP 15 –0.2 - 7.5 0.7 - 4 8 - 32 4 Aut. Man. LP and 060-126466 060-128466 -Dual KP 15 –0.2 - 7.5 0.7 - 4 8 - 32 4 Conv. 2 ) Conv. 2 ) HP 060-115466 3 ) 060-001066 3 ) -Dual KP 15 –0.9 - 7 0.7 8 - 32 4 Conv. 2 ) Conv. 2 ) signal 060-122066 - -For fluorinated refrigerants and R 717 (NH 3 )Low pressure (LP) High pressure (HP) ResetCode no.Pressure TypeRegulating Differential Regulating DifferentialContact1 m cap.range∆prange∆pLP/HP systemM10 × 0.75tube withbarbarbarbarM10 × 0.75Low KP 1A −0.2 → 7.5 0.7 → 4.0 Aut.060-116266 060-116066 3)Low KP 1A −0.9 → 7.0 Fixed 0.7 Man. 060-116166SPDTHigh KP 5A 8 → 32 1.8 → 6.0 Aut. 060-123066 3)High KP 5A 8 → 32 Fixed 3 Man. 060-115366 060-123166Dual KP 15A −0.2 → 7.5 0.7 → 4.0 8 → 32 Fixed 4 Aut./Aut. SPDT + LP and HP 060-129566 060-129366 3)Dual KP 15A −0.2 → 7.5 0.7 → 4.0 8 → 32 Fixed 4 Aut./Man. signal060-129666 060-129466Dual KP 15A −0.9 → 7.0 Fixed 0.7 8 → 32 Fixed 4 Conv./Conv. 2) SPDT LP signal 060-128366High KP 7ABS 8 → 32 Fixed 4 Man./Man. SPST 060-1205661) Pressure controls with gold-plated contacts2) Convertible reset: optional automatic or manual reset3) Enclosure IP441/4 in.ODFsolder6 mmODFsolderVarastotuotteiden numerot tummennettuOikeus muutoksiin ilman ennakkoilmoitusta pidätetään

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!