14.4. MAINTENANCE ON THE WATER SYSTEM<br />

With the system switched off, once a year carry out the following checks:<br />

• Check the operation and efficiency of the blowdown and safety valves. If they are defective, contact your<br />

authorised installer. IT IS STRICTLY FORBIDDEN TO REMOVE OR TAMPER WITH THE SAFETY<br />

DEVICES.<br />

• Check the thermal insulation of the filling pipe and the safety pipe.<br />

• Make sure that the system is filled and under pressure, checking the water level in the expansion tank; also<br />

check that it is working properly and check the efficiency of the safety pipe.<br />

15. SUMMER SHUTDOWN<br />

ATTENTION: The system must be kept constantly full of water even during the periods when the use of the<br />

thermoheating stove is not requested. During the winter, inactivity must be faced with the addition of<br />

antifreeze.<br />

When the fireplace, chimney and flue have been cleaned completely, eliminating the ash and any other residues, it is<br />

good practice to close all of the doors with the relative fireplace regulators. If the appliance is disconnected from the<br />

chimney, the outlet hole must be closed.<br />

It is recommended to clean the flue at least once a year; verifying in time the effective state of the seals, which if are<br />

not perfectly integral <strong>–</strong> i.e. do not adhere to the thermoheating stove <strong>–</strong> do not guarantee the good functioning of the<br />

appliance! They must therefore be replaced.<br />

If there is humidity in the place where the appliance is placed, place absorbent salts inside the fireplace of the latter.<br />

16. CONNECTION TO THE FLUE OF AN OPEN CHIMNEY OF FIREPLACE<br />

In the connection of the flue channel and the tract of pipe that connects the thermo-product to the flue, these simple<br />

but very important principles must be respected:<br />

• for no reason must a flue channel be used that has a diameter lower than that of the output collar with which<br />

the thermo-product is equipped;<br />

• every horizontal metre of the flue channel causes a sensitive loss of pressure, which must be compensated<br />

by rising of the flue;<br />

• the horizontal tract must never exceed 2m (UNI 10683-2005);<br />

• each bend in the flue channel notably<br />

reduces the chimney effect of the flue,<br />

which must be compensated by raising it<br />

adequately;<br />

• the UNI 10683-2005 <strong>–</strong> Standard ITALY<br />

envisions that the bends or variations of<br />

direction must never be more than 2<br />

including the entry into the flue.<br />

C - Infill<br />

In order to use the flue of an open chimney or<br />

fireplace, the hood must be closed hermetically<br />

below the intake point of the flue channel pos. A<br />

Picture 12.<br />

If the flue is too big (e.g. cm 30x40 or 40x50) it<br />

must be ducted with a stainless steel pipe with at<br />

least 200mm diameter, pos. B, taking care to close<br />

the space remaining between the pipe itself and<br />

the flue well, immediately under the chimney pot<br />

pos. C.<br />

For any clarifications, please contact your local<br />

dealer!<br />

A <strong>–</strong> Hermetic sealing<br />

Inspection<br />

hatch<br />

Picture 12<br />

7197100 Rev.05 <strong>–</strong> EN 29<br />