14.4. MAINTENANCE ON THE WATER SYSTEM<br />
With the system switched off, once a year carry out the following checks:<br />
• Check the operation and efficiency of the blowdown and safety valves. If they are defective, contact your<br />
authorised installer. IT IS STRICTLY FORBIDDEN TO REMOVE OR TAMPER WITH THE SAFETY<br />
DEVICES.<br />
• Check the thermal insulation of the filling pipe and the safety pipe.<br />
• Make sure that the system is filled and under pressure, checking the water level in the expansion tank; also<br />
check that it is working properly and check the efficiency of the safety pipe.<br />
15. SUMMER SHUTDOWN<br />
ATTENTION: The system must be kept constantly full of water even during the periods when the use of the<br />
thermoheating stove is not requested. During the winter, inactivity must be faced with the addition of<br />
antifreeze.<br />
When the fireplace, chimney and flue have been cleaned completely, eliminating the ash and any other residues, it is<br />
good practice to close all of the doors with the relative fireplace regulators. If the appliance is disconnected from the<br />
chimney, the outlet hole must be closed.<br />
It is recommended to clean the flue at least once a year; verifying in time the effective state of the seals, which if are<br />
not perfectly integral <strong>–</strong> i.e. do not adhere to the thermoheating stove <strong>–</strong> do not guarantee the good functioning of the<br />
appliance! They must therefore be replaced.<br />
If there is humidity in the place where the appliance is placed, place absorbent salts inside the fireplace of the latter.<br />
16. CONNECTION TO THE FLUE OF AN OPEN CHIMNEY OF FIREPLACE<br />
In the connection of the flue channel and the tract of pipe that connects the thermo-product to the flue, these simple<br />
but very important principles must be respected:<br />
• for no reason must a flue channel be used that has a diameter lower than that of the output collar with which<br />
the thermo-product is equipped;<br />
• every horizontal metre of the flue channel causes a sensitive loss of pressure, which must be compensated<br />
by rising of the flue;<br />
• the horizontal tract must never exceed 2m (UNI 10683-2005);<br />
• each bend in the flue channel notably<br />
reduces the chimney effect of the flue,<br />
which must be compensated by raising it<br />
adequately;<br />
• the UNI 10683-2005 <strong>–</strong> Standard ITALY<br />
envisions that the bends or variations of<br />
direction must never be more than 2<br />
including the entry into the flue.<br />
C - Infill<br />
In order to use the flue of an open chimney or<br />
fireplace, the hood must be closed hermetically<br />
below the intake point of the flue channel pos. A<br />
Picture 12.<br />
If the flue is too big (e.g. cm 30x40 or 40x50) it<br />
must be ducted with a stainless steel pipe with at<br />
least 200mm diameter, pos. B, taking care to close<br />
the space remaining between the pipe itself and<br />
the flue well, immediately under the chimney pot<br />
pos. C.<br />
For any clarifications, please contact your local<br />
dealer!<br />
A <strong>–</strong> Hermetic sealing<br />
Inspection<br />
hatch<br />
Picture 12<br />
7197100 Rev.05 <strong>–</strong> EN 29<br />