4.2 Display indications<br />
The inspection side of the unit has a display panel indicating various operation modes.<br />
Lightning – (1)<br />
Drop – (2)<br />
Triangle – (3)<br />
Fire – (4)<br />
Drop – (5)<br />
Fire – (6)<br />
Fan – (7)<br />
Lightning / Drop / Triangle / Fire – (1) (2)(3)(4)<br />
If the unit is switched on and off repeatedly on the main switch the LED’s will light up one by one in green before<br />
the actual mode is shown on the display.<br />
Lightning – constant green- (1)<br />
The LED lights up in green when power is connected to the unit<br />
Drop – constant green- (2)<br />
The LED lights up constantly in green when the compressor is in operation and the unit is in dehumidification<br />
mode.<br />
Failure on the low-pressure pressostat<br />
Lightning – constant green + Drop – flashes on and off in green + Triangle – constant red (1) (2)(3)<br />
A constantly green Lightning indicates that power is on. The Drop and the Triangle LEDs flash on and off in green<br />
and lights up constantly in red, respectively, to indicate that there has been a failure on the unit by the low-pressure<br />
pressostat. If the low-pressure pressostat registers a too low pressure in the cooling circuit, caused by a too low<br />
temperature across the evaporator, the unit will be stopped until the required pressure has been reestablished and<br />
the low-pressure pressostat then switches on the unit again.<br />
When the unit has been switched on again, the Triangle light goes out and the Drop continues to flash on and off in<br />
green. The Lightning is still green.<br />
Drop – flashing on and off in green + Lighting – constant green – (2)(1)<br />
When the Drop flashes on and off in green and the Lighting is constant green, this indicates that the unit is working<br />
but there has been a failure on the unit through the LP pressostat.<br />
The flashing Drop is switched off by turning the unit OFF and ON on the main switch.<br />