15. CONNECTING A CHIMNEY OR OPEN FURNACE TO THE FLUE<br />
The smoke channel is the section of tube that connects the product to the flue, in the connection these simple but<br />
very important principles must be followed:<br />
• for no reason must the smoke channel be used with a diameter lower than that of the neck of the outlet with<br />
which the product is fitted;<br />
• each metre of horizontal route of the smoke channel causes a small leak of charge which should be<br />
<strong>com</strong>pensated for by raising the flue;<br />
• the horizontal section must never be higher than 2 m (UNI 10683-2005);<br />
• each bend of the smoke channel considerably reduces the draught of the flue which must be <strong>com</strong>pensated<br />
for by raising it suitably;<br />
• the UNI 10683-2005 Regulation –Italy requires that the bends or variations of direction must in no case be<br />
greater than 2 including the emission into the flue.<br />
Wanting to use the flue of a chimney or open furnace, it will be necessary to close the hood hermetically below the<br />
inlet point of the smoke channel pos. A Picture 10.<br />
If the flue is too large (e.g. cm 30x40 or 40x50) it is necessary to duct it with a stainless steel tube of at least 200 mm<br />
of diameter, pos. B taking care to close the space between the tube itself and the flue immediately below the chimney<br />
cap pos. C.<br />
C - Plugging<br />
B<br />
A – Hermetic closure<br />
Inspection<br />
hatch<br />
Picture 10<br />
For further information please contact your Dealer.<br />