7.- Warnings<br />
ŸDetectors measure gas concentration in a point, if the gas leak does not reach the detector, the alarm will<br />
not activate.<br />
ŸDetectors cannot supervise areas, and if perimeter supervision is required, several detectors should be<br />
installed surrounding the area to be supervised.<br />
ŸThoroughly studying the location of the detector/s is recommended, bearing in mind the areas most sensitive to<br />
suffering leaks, the type of gas used, the size and shape of the room, the air flows, the maintenance work, etc.<br />
ŸThe detectors described have been designed to detect gas concentrations capable of affecting the<br />
environmental conditions of the room (movement of oxygen), and the detection of small coolant leaks is not<br />
guaranteed.<br />
8.- Technical data<br />
<strong>AKO</strong>-52210<br />
Power supply ........................................................................................................................90-260 V~ 50/60 Hz<br />
Maximum input power ................................................................................................................................10 VA<br />
No. of inputs.......................................................................................................................................................1<br />
Compatibility of inputs..................................................................................................Only <strong>AKO</strong>-5221x detectors<br />
Alarm / pre-alarm relay ...........................................................................................SPDT 230 Vac, 16 A, cos j =1<br />
Working ambient temperature ..........................................................................................................0 ºC to 50 ºC<br />
Storage ambient temperature ........................................................................................................-30 ºC to 70 ºC<br />
Protection degree .........................................................................................................................................IP 40<br />
Installation category ....................................................................................................................II s/ EN 61010-1<br />
Pollution degree ..........................................................................................................................II s/ EN 61010-1<br />
Double isolation between power supply, secondary circuit and relay output.<br />
Sound power..........................................................................................................................90 dB(A) at 1 metre<br />
EMC Standard.......................................................................................................................................EN 61000<br />
<strong>AKO</strong>-5221x<br />
Power supply..................................................................................................................................15 Vdc ±3 Vdc<br />
Consumption Typical <strong>AKO</strong>-52211/12/13/14 .....................................................................................75 mA<br />
<strong>AKO</strong>-52215......................................................................................................30 mA<br />
Maximum <strong>AKO</strong>-52211/12/13/14 ...................................................................................100 mA<br />
<strong>AKO</strong>-52215......................................................................................................50 mA<br />
Working ambient temperature.......................................................................................................-20 ºC to 50 ºC<br />
Storage ambient temperature ........................................................................................................-20 ºC to 60 ºC<br />
Range of maximum allowed humidity .............................................................5 - 85% RH (without condensation)<br />
Protection degree .........................................................................................................................................IP 40<br />
Sensor type<br />
<strong>AKO</strong>-52211/12/13/14 ........................................................Sn02 (Metal Oxide Semiconductor)<br />
<strong>AKO</strong>-52215.............................................................NDIR (Non-Dispersive Infrared Technology)<br />
Display range (<strong>AKO</strong>-52215)............................................................................................................0 - 9999 ppm<br />