SIRIO<br />

S2/T<br />

EMERGENCY<br />

LUNG VENTILATOR<br />

VENTILATORE<br />

POLMONARE<br />

PER EMERGENZA<br />

®


Nowadays the<br />

professionality is also<br />

available for emergency lung<br />

ventilation.<br />

SIRIO S2/T is an important tool for<br />

hospital in fact it can be placed in the<br />

Intensive Care, Recovery, and First-Aid<br />

Units.<br />

It only needs to be connected to the<br />

oxygen outlet size 3/4 lpm.<br />

The ambient air is collected by<br />

a jet inhalation system with adjustable<br />

percentages.<br />

Particular of the valves group<br />

and handle with universal<br />

supports.<br />

Particolare del gruppo valvole<br />

di tipo compatto e maniglia<br />

multifunzione.<br />

Particular of the sylicon<br />

patient circuit with valve.<br />

Particolare del<br />

circuito paziente in silicone<br />

con valvola.<br />

SIRIO S2/T is available in portable version with a<br />

professional bag, or on light trolley.<br />

SIRIO S2/T è disponibile in versione da trasporto<br />

con borsa professionale, o su carrello.<br />

®<br />

Oggi la professionalità è<br />

anche disponibile nella<br />

ventilazione polmonare in<br />

emergenza.<br />

Il SIRIO S2/T è un ausilio importante,<br />

infatti può essere collocato in reparto<br />

intensivo, post-operatorio, e pronto<br />

soccorso.<br />

Non richiede particolari alimentazioni che<br />

non l'ossigeno in misura di 3/4 litri/minuto.<br />

L'aria è prelevata dall'ambiente attraverso<br />

il sistema jet inhalation a percentuali<br />

selezionabili.


PSV + CPAP in EMERGENCY<br />

Alarms<br />

Allarmi<br />

Rate<br />

Frequenza<br />

Respiratoria<br />

O2 / Air Mixer<br />

Mixer O2 AIR<br />

Ventilation modes:<br />

Volumetric Time Cycled and Pressure metric<br />

IPPV + AST<br />

PSV<br />

CPAP<br />

PEEP<br />

It suitable for all types of lung ventilations,<br />

including intensive care and awakening with PSV<br />

(Pressure Support Ventilation) and CPAP.<br />

LUNG VENTILATOR<br />

VENTILATORE POLMONARE<br />

SIRIO S2/T<br />

Minute Volume<br />

Volume Minuto<br />

Limit Pressure / CPAP<br />

Limite di Pressione / CPAP<br />

PSV + CPAP in EMERGENZA<br />

PEEP / PEEP<br />

®<br />

Operative Modes<br />

Modi Operativi<br />

Airways Pressure<br />

Pressione vie aeree<br />

Tipo di ventilazione:<br />

Volumetrico Ciclato a tempo e Pressometrico<br />

IPPV + AST<br />

PSV<br />

CPAP<br />

PEEP.<br />

Adatto per tutte le ventilazioni polmonari sia<br />

intensive che svezzamenti respiratori con PSV<br />

(Pressure Support Ventilation)<br />

e CPAP.


Cod. 09436 - SIRIO S2/T<br />

Standard Accessories:<br />

- n.1 power supply unit 220V-12V (code G30146100)<br />

- n.1 vehicular power supply cable 12V-(code G30147100)<br />

- n.1 O 2 supply hose (code G60005100)<br />

- n.1 Silicone patient circuit (code 102631/SLV)<br />

- User's Manual.<br />

REG. N. 327<br />

UNI EN ISO 9001-2000<br />

UNI CEI EN ISO 13485-2002<br />

FOR OTHER ACCESSORIES, PLEASE REFER TO THE PRICE LIST IN FORCE - PER ALTRI ACCESSORI FARE RIFERIMENTO AL LISTINO PREZZI IN VIGORE<br />

s.r.l<br />

E N G I N E E R I N G<br />

INTERNATIONAL GROUP<br />

DATA FOR ORDERING - DATI PER L’ORDINAZIONE:<br />

Dotazione Standard:<br />

- n. 1 alimentatore 220V - 12V<br />

- n. 1 cavo alimentaz. veicolare 12V (Cod.G30147100)<br />

- n. 1 tubo alimentazione O 2 (Cod. G60005100)<br />

- n. 1 circuito paziente in silicone (Cod. 102631/SLV)<br />

- Manuale d'uso<br />

SIARE is not only Research, Designing and Manufacturing but with an efficient and expertise technical service<br />

available in 5 continents and 60 Agencies around the world grants the maximum efficiency of its products.<br />

SIARE non è solo Ricerca, Progettazione, Produzione e Vendita ma, con un Servizio di Assistenza in<br />

5 continenti e 60 Agenzie nel mondo, Vi seguirà passo passo lungo la strada.<br />

Via G. Pastore, 18<br />

40056 Crespellano(BOLOGNA) ITALY<br />

Phone:+39 (051) 96.98.02 - Fax: +39 (051) 96.93.66<br />

E-mail: mail@siare.it - Internet:www.siare.it<br />

®<br />

Code G00180000<br />

Trolley for ventilator<br />

Carrello per ventilatore polmonare<br />

Code G00130000<br />

Stand for ventilator on wheels<br />

Stativo per ventilatore<br />

Code 06750/SB<br />

Stainless steel patient circuit supporting arm<br />

with clamp<br />

Braccio di supporto per circuito paziente<br />

Code 03000<br />

VAPOUR 2 Electronic humidifier<br />

Umidificatore VAPOUR 2<br />

Code A2000<br />

Hose for humidifier connection, adult<br />

Tubo per umidificatore adulti<br />

Distributed by:<br />

Code G90003000<br />

Bag for ventilator<br />

Borsa da trasporto per ventilatore<br />

Code G00127000<br />

Ventilator support with housing for 2 lt.<br />

O 2 cylinder<br />

Supporto in alluminio per ventilatore e<br />

bombola da 2 lt<br />

Code 10001/2<br />

2 lt. O 2 cylinder, standard connection<br />

Bombola O 2 da 2 lt., tipo Italia<br />

Code 10006/2<br />

2 lt. O 2 cylinder, Pin Index connection<br />

Bombola O 2 da 2 lt., tipo Pin Index<br />

Code 108001/CM<br />

O 2 pressure reducer, standard connection<br />

Riduttore di pressione O 2, tipo Italia<br />

Code 109006/CM<br />

O 2 pressure reducer, Pin Index connection<br />

Riduttore di pressione O 2, tipo Pin Index<br />

Code G00128000<br />

Vehicle bag support<br />

Supporto borsa per autoveicolo<br />