04.12.2013 Views

FG7ORPu TUNNELFLEX - 0,6/1 kV CABLES DESIGN

TUUNNELFLEX cable in PUR for Reeling Cables

TUUNNELFLEX cable in PUR for Reeling Cables

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Prysmian Cavi e Sistemi Energia Italia Srl<br />

Engineering<br />

Rev. 1<br />

<strong>CABLES</strong> FOR MOBILE APPLICATIONS<br />

15/03/2007<br />

STSX -1-1105<br />

<strong>FG7ORPu</strong> <strong>TUNNELFLEX</strong> - 0,6/1 <strong>kV</strong><br />

SENZA PROTEZIONE ANTITORSIONE / WITHOUT ANTITWISTING PROTECTION<br />

<strong>CABLES</strong> <strong>DESIGN</strong> & DATA TABLES<br />

1 15-Mar-07 Changed insulation colors - PIRELLI to PRYSMIAN CS<br />

0 18-May-05 Issued for design assessment a CS<br />

Rev. Date Description prepared By<br />

1 of 3


Prysmian Cavi e Sistemi Italia Srl<br />

Engineering<br />

Rev. 1<br />

15/03/2007<br />

<strong>CABLES</strong> FOR MOBILE APPLICATIONS<br />

STSX-1-1105<br />

<strong>FG7ORPu</strong> <strong>TUNNELFLEX</strong> - 0,6/1 <strong>kV</strong><br />

SENZA PROTEZIONE ANTITORSIONE / WITHOUT ANTITWISTING PROTECTION<br />

4 3 2 1<br />

Impiego: Application:<br />

Per l'alimentazione di macchine per servizio mobile con alto<br />

rischio di danneggiamento meccanico miniere, gallerie.<br />

Nel <strong>TUNNELFLEX</strong>, la mancanza di elementi antitorsione<br />

ne consente l'impiego limitatamente ad applicazioni con<br />

flessioni su un solo piano.<br />

Velocita max 60 m/min<br />

Costruzione:<br />

Power supply to mobile equipment with high risk of<br />

mechanical damage in mining and tunneling.<br />

<strong>TUNNELFLEX</strong> cable is suitable for application<br />

where it is deflected in one plane only.<br />

Maximum speed 60 m/min<br />

Construction:<br />

1 Anime di fase 1 Phase cores<br />

Conduttore: Rame rosso, flessibile classe 5 secondo<br />

Conductor:<br />

IEC 60228<br />

Isolamento<br />

Mescola speciale HEPR<br />

Insulation<br />

2 Anime di terra 2 Earth cores<br />

Conduttore: Rame rosso, flessibile classe 5 secondo<br />

Conductor:<br />

IEC 60228<br />

Plain copper, flexible class 5 according to<br />

IEC 60228<br />

HEPR special compound<br />

Plain copper, flexible class 5 according to<br />

IEC 60228<br />

Isolamento Mescola speciale XLPE<br />

colore giallo/verde<br />

Cavo Cable<br />

Riunione Cores arrangements Anime di fase cordate con negli ineterstizi le<br />

anime di terra<br />

Insulation<br />

XLPE special compound<br />

colour: yellow/green<br />

Phase cores laid up with earth cores in the<br />

interstices<br />

3 Guaia interna Mescola speciale a base PVC flessibile<br />

3 Inner sheath<br />

4 Guaina esterna Mescola speciale a base poliuretano resistente 4 Outer sheath<br />

all'abrasione e alla lacerazione<br />

Marcatura ad<br />

inchiostro es.:<br />

colore GIALLO<br />

PALAZZO - <strong>TUNNELFLEX</strong> 0,6/1 <strong>kV</strong> 3x..+3x..<br />

PVC flexible special compound<br />

Polyurethane special compound<br />

abrasion and tear resistant<br />

colour: YELLOW<br />

Marking (inkjet printed)<br />

Dati elettrici<br />

Electrical data<br />

Tens. nominale Uo/U <strong>kV</strong><br />

0,6/1 0,6/1<br />

Rated voltage Uo/U <strong>kV</strong><br />

Tensione massima <strong>kV</strong><br />

1,2<br />

Max. oper. voltage <strong>kV</strong><br />

Tensione di prova <strong>kV</strong> 3,5 3,5<br />

Test voltage <strong>kV</strong><br />

1,2<br />

Prepared and chcked by C. Soccal<br />

2 of 3


Prysmian Cavi e Sistemi Energia Italia Srl<br />

Engineering<br />

Rev. 1<br />

15/03/2007<br />

STSX-1-1105<br />

Dati tecnici / Technical data<br />

Cable size Conductor Minimum Maximum Weight Max. permissible Short circuit<br />

Current carrying capacity<br />

diameter diameter diameter approx tensile load<br />

Spirale or current 1 sec.<br />

approx Static Dynamic laid straight 1 layer 2 Layer 3 layer 4 layer 90 °C - 250 °C<br />

n x mm² mm mm mm kg/km N N A at 30 °C A at 30 °C A at 30 °C A at 30 °C A at 30 °C kA<br />

0,6/1 <strong>kV</strong><br />

3x25+3G6 6,5 24,0 26,5 1.250 1125 1500 131 105 80 65 56 3,58<br />

3x35+3x3G6 7,5 26,0 29,0 1.540 1575 2100 162 130 99 80 69 5,01<br />

3x50+3G10 9,1 29,5 32,5 2.200 2250 3000 202 162 124 99 85 7,15<br />

3x70+3G16 10,8 34,0 37,5 3.090 3150 4200 250 200 153 123 105 10,01<br />

3x95+3G16 12,1 38,5 42,0 3.760 4275 5700 301 241 184 148 127 13,59<br />

3x120+3G25 14,3 43,5 47,0 4.970 5400 7200 352 282 215 173 148 17,16<br />

3x150+3G25 16,1 48,5 52,0 6.000 6750 9000 404 324 247 198 170 21,45<br />

3x185+3G35 17,5 52,5 56,5 7.290 8325 11100 461 369 282 226 194 26,46<br />

3x240+3G50 19,9 58,5 63,0 9.440 10800 14400 547 438 334 269 230 34,32<br />

Coefficienti di correzione per temperature diverse da 30 °C<br />

Correction factors for ambient temperature other than 30 °C<br />

°C 20 25 35 40 45 50<br />

K 1,1 1,05 0,95 0,89 0,84 0,77<br />

Raggio minimo di piegatura<br />

Minimum bending radius<br />

Fixed<br />

installation<br />

6 x OD<br />

OD= overall diameter<br />

On drums<br />

10 x OD<br />

Limiti di termperatura<br />

Temperture limits<br />

ambient<br />

fixed -30°C flex -20 °C<br />

conductor<br />

+90 °C<br />

Prepared and chcked by C. Soccal<br />

3 of 3