Troubleshooting<br />

Error code Fault / Fault description Remedy<br />

14<br />

E051<br />

E052<br />

E053<br />

E054<br />

E055<br />

E056<br />

E057<br />

E058<br />

E059<br />

E060<br />

E061<br />

E062<br />

E063<br />

Safety switch filter panel<br />

facial tanner top right and rear left<br />

Fault in the opening mechanism<br />

of the reflector-arm<br />

Safety switch UV high pressure lamps in the<br />

head area<br />

Safety switch UV high pressure lamps in the foot<br />

area<br />

Fault (temperature limiter)<br />

facial tanner 1<br />

Fault (temperature limiter)<br />

facial tanner 2 rear<br />

Fault (temperature limiter)<br />

Facial tanner front<br />

Fault (temperature limiter)<br />

Facial tanner middle<br />

Fault (temperature limiter)<br />

Facial tanner rear<br />

Fault (temperature limiter)<br />

Facial tanner side section<br />

Panel switch canopy acrylic cover or decorative<br />

trim panel<br />

Panel switch acrylic cover base/<br />

side section<br />

Panel switch acrylic cover side section has triggered<br />

E086 Monitor switched off by overheating protection.<br />

– Check safety chain:<br />

1. 3 x temperature limiters facial<br />

tanner filter panels<br />

2. Limit switch trim panel (canopy)<br />

3. 3 x temperature limiters facial<br />

tanner<br />

4. Temperature limiter UV lowpressure<br />

lamps (canopy)<br />

5. Temperature limiter UV lowpressure<br />

lamps (base)<br />

Allow monitor to cool for approx.<br />

2 hours. Then restart MULTIVI-<br />

SION box.