ZO<br />

TENSIONE MISURABILE<br />

100/200V AC<br />

100/200/400V AC<br />

100/200/400V AC<br />

TIPO DI MISURAZIONE<br />

Monofase (F+N)<br />

Monofase (3F)<br />

Trifase (3F)<br />

Monofase (F+N)<br />

Monofase (3F)<br />

Trifase (3F)<br />

Trifase (3F+N)<br />

Monofase (F+N)<br />

Monofase (3F)<br />

Trifase (3F)<br />

Trifase (3F+N)<br />

LETTURA<br />

1 canale monofase o<br />

1 canale trifase<br />

1 canale monofase o<br />

1 canale trifase<br />

3 canali monofase F+N o 1 canale trifase<br />

MISURE Energia (attiva). Potenza attiva.<br />

Corrente, tensione, consumo energetico in valuta<br />

Energia (attiva, reattiva, apparente).<br />

Potenza attiva, reattiva, apparente.<br />

Corrente, tensione, frequenza, fattore di potenza,<br />

consumo energetico in valuta, conta impulsi, contaore,<br />

misura simultanea della potenza e degli impulsi<br />

Energia (attiva, reattiva, apparente).<br />

Energia prodotta attiva e reattiva.<br />

Potenza attiva, reattiva, apparente.<br />

Corrente, tensione, frequenza, fattore di potenza,<br />

consumo energetico in valuta. Temperatura<br />

MINIMA POTENZA MISURATA 11 Watt (CT 5A) 11 Watt (CT 5A)<br />

PRECISIONE ENERGIA ATTIVA<br />

Classe 2% (IEC62053-23)<br />

Classe 2% (IEC62053-23)<br />

Classe 1% (IEC62053-21) per AKW8115<br />

TRASFORMATORI AMPEROMETRICI<br />

FUNZIONE DI ALLARME<br />

(Segnale in uscita)<br />

5A/50A/100A/250A/400A (dedicati)<br />

•<br />

5A/50A/100A/250A/400A (dedicati)<br />

•<br />

1,1 Watt (CT 5A)<br />

Classe 1% (IEC62053-21)<br />

1A o 5A (commerciali)<br />

—<br />

SPEC CHE TEC CHE<br />

TENSIONE DI ALIMENTAZIONE<br />

100 - 240V AC<br />

100 - 240V AC<br />

85 - 264V AC<br />

100 -300V DC<br />

POTENZA ASSORBITA<br />

(240VAC A 25°C)<br />

6VA<br />

8VA<br />

5VA<br />

3W<br />

PORTA DI COMUNICAZIONE<br />

RS485<br />

Protocollo Mewtocol e Modbus RTU<br />

RS485<br />

Protocollo Mewtocol e Modbus RTU<br />

RS485<br />

Protocollo Mewtocol, Modbus RTU, DL/T645-2007<br />

UNITÀ COLLEGABILI<br />

ESPANDIBILITÀ<br />

USCITA IMPULSI<br />

INGRESSO IMPULSI<br />

DISPLAY<br />

max. 99<br />

—<br />

•<br />

—<br />

LCD con backlight<br />

8 cifre, 7 segmenti<br />

max. 99<br />

—<br />

LCD<br />

8 cifre, 7 segmenti LED<br />

•<br />

•<br />

max. 99<br />

—<br />

—<br />

—<br />

LCD con backlight<br />

MEMORIA<br />

EEPROM<br />

EEPROM<br />

EEPROM<br />

MEMORIA DATI<br />

—<br />

• (Modello KW8-H)<br />

•<br />

OROLOGIO - CALENDARIO<br />

—<br />

• (Modello KW8-H)<br />

—<br />

SLOT SD/SDHC CARD<br />

—<br />

—<br />

—<br />

CERTIFICAZIONI<br />

CE, S<br />

CE, S<br />

CE<br />

COD C D ORD AZ O E<br />

AKW7111<br />

AKW8111<br />

AKW8111H<br />

AKW8115<br />

AKW91110<br />

SO TWARE<br />

KW Monitor: Software per la visualizzazione dei dati raccolti dall'analizzatore di rete.<br />

KW View: Software per la visualizzazione dei dati memorizzati nell'SD Card dell'analizzatore di rete.<br />

KW Watcher: Software per la visualizzazione dei dati raccolti nel Data logger (DLU, DLL).<br />

I software sono scaricabili gratuitamente dal sito web wwww.panasonic-electric-works.it<br />

AKW4801C: 5/50A, AKW4802C: 100A, AKW4803C: 250A, AKW4804C: 400A, AKW4808C: 600A* (*) Solo per KW2G<br />

CT commerciali con secondario da 1A / 5A<br />

Max corrente misurabile 4000 A<br />

TRAS ORMATOR AMPEROMETR C<br />

www.panasonic-electric-works.it<br />