Isolation Measurement PV Converter<br />

Application Note AN10-1AG<br />

Application<br />

The photovoltaic construction have to isolate across<br />

earth very well. Currents which based on bad isolation<br />

cause to high contact risk and additional power loss.<br />

The complete isolation resistance is made up of<br />

different components:<br />

PV-Module<br />

<br />

<br />

DC-Cable<br />

Converter<br />

Converters without an internal transformer are not<br />

galvanically isolated from the power net. As per DIN<br />

VDE 0126-1-1 it´s not allowed to go below a limit<br />

isolation resistance between the converter and the<br />

power net.<br />

Based on the missing galvanic isolation a continued<br />

measuring of the isolation resistance during the<br />

converter is running is not possible. Therefore the<br />

isolation resistance is measured before the converter is<br />

connected to the power net (current sensitive fault<br />

protection).<br />

Products<br />

Modern converters contain a integrated isolation<br />

control. This control system check all components of<br />

the photovoltaic construction of isolation failure. This<br />

control system has high requirements on the<br />

assembled<br />

relay.’<br />

Reed Relays from MEDER perfectly fulfill such<br />

requirements. The Reed Technology makes it possible<br />

to reach isolation resistance >10G Ohm. Another<br />

advantage is the low power consumption. Reed Relays<br />

only need energy during the switching process which<br />

has a positive influence of the overall efficiency of the<br />

converter. The high amount of 10 9 switching cycles<br />

makes the Reed Relays suitable for long life<br />

applications.<br />

Series<br />

Dimensions<br />

Contact Configuration<br />

LI 1 Form A –<br />

Normally Open<br />

BE 1 Form A –<br />

Normally Open<br />

KT 1 Form A –<br />

Normally Open<br />

Dimension<br />

L x W x H<br />

(mm)<br />

30x10x10.4<br />

33x10x10<br />

30x12.5x13.1<br />

Operating Characteristics<br />

Series<br />

Coil Isolation Switching Isolation Switching Carry<br />

Voltage Voltage Voltage Resistance Current Current<br />

Power<br />

V(DC) Max (VDC) Max (VDC) Max (Ω) Max (A) Max (A) Max (W)<br />

LI 5,12,24 4,000 1,000 >10G 1,0 5 100<br />

BE 5,12,24 4,000 1,000 >10G 1,0 2,5 100<br />

KT 5,12,24 8,000 1,000 >10G 1,0 1,0 100<br />

MEDER electronic • www.meder.com Page 1<br />