<strong>Contatori</strong> trifase - <strong>BASIC</strong><br />

Connessione <strong>di</strong>retta 80 A<br />

Dimensioni<br />

<strong>di</strong>gitale <strong>di</strong> energia attiva e con contatore parziale azzerabile,<br />

con comunicazione incorporata Modbus RTU oppure M-Bus - 2 tariffe<br />

Connessione a mezzo TA .../5 A fino 10.000 A<br />

Dimensioni<br />

ECSEM71-ECSEM75MID<br />

ECSEM72-ECSEM76MID<br />

ECSEM63-ECSEM67MID<br />

ECSEM64-ECSEM68MID<br />

45 90<br />

45 90<br />

72<br />

6<br />

44<br />

64<br />

72<br />

6<br />

44<br />

ITALIANO<br />

Schemi <strong>di</strong> collegamento<br />

Modbus RTU or-oder-oppure M-Bus<br />

230 VAC<br />

Shield - Schild<br />

Schermo<br />

RT D- D+<br />

Schemi <strong>di</strong> collegamento<br />

Modbus RTU or-oder-oppure M-Bus<br />

Shield Shield<br />

Schild Schild<br />

Schermo Schermo<br />

230 V a.c.<br />

RT D- D+ D- D+<br />

1 2 3 4 5 6<br />

N<br />

Tarife-Tariff<br />

Tariffa-Tarifas<br />

Tarifs<br />

L1 L1 L2 L2 L3 L3<br />

7<br />

ECSEM71-ECSEM75MID<br />

ECSEM72-ECSEM76MID<br />

1 2 3 4 5 6 7 8 9<br />

Tarife-Tariff<br />

Tariffa-Tarifas<br />

Tarifs<br />

k1 L1 I1 k2 L2 I2 k3 L3 I3<br />

10<br />

N<br />

ECSEM63-ECSEM67MID<br />

ECSEM64-ECSEM68MID<br />

k<br />

l<br />

k<br />

l<br />

k<br />

l<br />

3 x 6A<br />

L1<br />

L2<br />

L3<br />

N<br />

3 x 80 A<br />

230/400 VAC<br />

Modbus RTU or-oder-oppure M-Bus<br />

L1<br />

L2<br />

L3<br />

N<br />

K L K L K L<br />

230/400 VAC<br />

Modbus RTU or-oder-oppure M-Bus<br />

Shield Shield<br />

Schild Schild<br />

Schermo Schermo<br />

230 V a.c.<br />

RT D- D+ D- D+<br />

N<br />

230 VAC<br />

Tarife-Tariff<br />

Tariffa-Tarifas<br />

Tarifs<br />

Shield - Schild<br />

Schermo<br />

RT D- D+<br />

1 2 3 4 5 6<br />

L1 L1 L2 L2 L3 L3<br />

7<br />

ECSEM71-ECSEM75MID<br />

ECSEM72-ECSEM76MID<br />

3 x 6A<br />

1 2 3 4 5 6 7 8 9<br />

Tarife-Tariff<br />

Tariffa-Tarifas<br />

Tarifs<br />

k1 L1 I1 k2 L2 I2 k3 L3 I3<br />

k l k l k l<br />

10<br />

N<br />

ECSEM63-ECSEM67MID<br />

ECSEM64-ECSEM68MID<br />

L1<br />

L2<br />

L3<br />

N<br />

3 x 80 A<br />

230/400 VAC<br />

L1<br />

L2<br />

L3<br />

N<br />

K L K L K L<br />

230/400 VAC<br />

Modbus RTU or-oder-oppure M-Bus<br />

Shield Shield<br />

Schild Schild<br />

Schermo Schermo<br />

230 V a.c.<br />

RT D- D+ D- D+<br />

1 2 3<br />

Tarife-Tariff<br />

Tariffa-Tarifas<br />

Tarifs<br />

4 5 6<br />

7<br />

8<br />

9<br />

10<br />

ECSEM64-ECSEM63<br />

k1 L1 I1<br />

k2 L2 I2 k3 L3 I3<br />

N<br />

k<br />

l<br />

k<br />

l<br />

3 x 6A<br />

Il Neutro deve essere collegato al Contatore<br />

L1<br />

L2<br />

L3<br />

N<br />

K L<br />

K L<br />

230/400 VAC<br />

Il Neutro deve essere collegato al Contatore<br />

Per la protezione della linea si consiglia un fusibile da 80 A.<br />

misura<br />

- 46 -<br />

Strumenti <strong>di</strong> Misura Modulari DIN e Moduli per la Comunicazione<br />

Istruzioni per il collegamento dei TA<br />

Per la protezione della linea si consiglia un fusibile da 6 A.<br />

I trasformatori <strong>di</strong> corrente non devono funzionare con i terminali/morsetti aperti, perché possono<br />

aversi delle tensioni pericolosamente elevate, che possono provocare lesioni alle persone e danni<br />

alle cose. I trasformatori sono inoltre esposti al sovraccarico termico.