27.02.2015 Views

Exhaust Emission Data Sheet 47GGFE - Cummins Power Generation

Exhaust Emission Data Sheet 47GGFE - Cummins Power Generation

Exhaust Emission Data Sheet 47GGFE - Cummins Power Generation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Exhaust</strong> <strong>Emission</strong> <strong>Data</strong> <strong>Sheet</strong><br />

<strong>47GGFE</strong><br />

60 Hz Generator Set<br />

Engine Information:<br />

Model: Ford ESG-642 Bore: 3.81 in. (97 mm)<br />

Type: 4 Cycle, V 6 Cylinder Spark-Ignited Stroke: 3.74 in. (95 mm)<br />

Aspiration: Natural Displacement: 256 cu. in. (4.2 liters)<br />

Compression Ratio: 9.3:1<br />

<strong>Emission</strong> Control Device: None<br />

Natural Gas<br />

Propane<br />

PERFORMANCE DATA Standby Prime Standby Prime<br />

Genset Rating (kw) @ 60 Hz 42 36 47 40<br />

BHP @ 1800 RPM (60 Hz) 67 58 74 63<br />

Fuel Consumption (SCFH) 576 507 246 216<br />

Air to Fuel Ratio 17.3:1 17.3:1 15.6:1 15.6:1<br />

<strong>Exhaust</strong> Gas Flow (CFM) 323 281 330 288<br />

<strong>Exhaust</strong> Gas Temperature (°F) 1084 1042 1107 1062<br />

EXHAUST EMISSION DATA<br />

HC (Total Unburned Hydrocarbons) 0.7 0.7 0.7 0.6<br />

NOx (Oxides of Nitrogen as NO2) 12.1 12.4 12.7 13.9<br />

CO (Carbon Monoxide) 7.9 7.6 12.7 10.3<br />

PM10 (Particular Matter) Negligible Negligible Negligible Negligible<br />

All values are Grams per HP-Hour<br />

TEST CONDITIONS<br />

<strong>Data</strong> was recorded during steady-state rated engine speed (± 25 RPM) with full load (±2%). Pressures, temperatures,<br />

and emission rates were stabilized.<br />

Fuel Specification:<br />

Natural Gas:<br />

Propane:<br />

Fuel Temperature:<br />

Fuel Pressure:<br />

Intake Air Temperature:<br />

Barometric Pressure:<br />

Dry processed natural gas with 905 BTU per standard cubic foot LHV<br />

Meets the requirements for Commercial Grade Propane under the ASTM D1835 Standard<br />

Specification for Liquefied Gases<br />

60 ± 9 °F at Flow Transmitter<br />

14.73 PSIA ± 0.5 PSIA at Flow Transmitter<br />

77 ± 9 °F at inlet<br />

29.92 in. Hg ± 1 in. Hg<br />

All emission data is a calculated average of engines tested under the conditions shown above. These data are subjected to instrumentation and<br />

engine-to-engine variability. Field emission test data are not guaranteed to these levels. Actual field test results may vary due to test site conditions,<br />

installation, fuel specification, test procedures and instrumentation. Engine operation with excessive air intake or exhaust restriction beyond published<br />

maximum limits, or with improper maintenance, may results in elevated emission levels.<br />