Drying<br />

Drying mode where the temperature can be set in steps in the range from +16 to +30ºC.<br />

The following is used as standard for new registrations: fan speed: 3, air swing: 1<br />

<strong>SMS</strong>: DRY 16~30 (E.g. DRY 18) = Drying +18ºC<br />

NB! Check the drain hose of the heat pump before operation.<br />

Fan Speed<br />

Change the fan speed regardless of the operating mode in steps from 0 to 5.<br />

0=auto, 1-5 are different speed steps where 1=lowest speed and 5=highest speed<br />

<strong>SMS</strong>: FanS 0~5 (E.g. FANS 3) = Fan speed level 3<br />

air Swing<br />

Change air swing regardless of the operating mode in steps from 0 to 5.<br />

0=Auto, 1-5 are directions in different steps where 1=Horizontal and 5=Vertical<br />

<strong>SMS</strong>: aiRS 0~5 (E.g. AIRS 2) = Air Swing level 2<br />

Start / Stop<br />

Start or stop the heat pump operation. When restarted the heat pump always starts in<br />

the last used operating mode before the pump was stopped; this applies also in case of<br />

power failure.<br />

<strong>SMS</strong>: On (E.g. ON) = Starts the heat pump<br />

<strong>SMS</strong>: OFF (E.g. OFF) = Stops the heat pump<br />

* The command works only on heat pump models equipped with this function.<br />

Please see the operation manual to find out what the functions of your model are.<br />

temperature Readings<br />

The remote control has a built-in sensor that senses ambient temperature.<br />

For optimum temperature sensing, the remote control must never be placed close to the<br />

front of the heat pump, nor should the sensor be covered since it would then be disturbed by<br />

temperature fluctuations. With a text message the user can find out what the current<br />

temperature in the place where <strong>SMS</strong>-<strong>953</strong> is installed is.<br />

<strong>SMS</strong>: tgEt (E.g. TGET) = Current temperature status<br />

(E.g. Received <strong>SMS</strong>: ”Confirm TMP:21C ADJ:+05TGET” = +21ºC with +0.5ºC adjustment)<br />

temperature adjustment<br />

If the temperature readings are misleading due to the location of the unit, it is possible to<br />

adjust the readings so that they complies with one’s own measurements.<br />

<strong>SMS</strong>: taDJ XYY (E.g. TADJ 120) = Negative correction of -2,0ºC<br />

X = 0 for a positive value, X = 1 for a negative value<br />

YY = 05 / 10 / 15 / 20 / 25 / 30 / 35<br />

(Ex. 05=0.5ºC / 10=1.0ºC / 15=1.5ºC / 20=2.0ºC / 25=2.5ºC / 30=3.0ºC / 35=3.5ºC)<br />

temperature alarms<br />

Change the temperature value set for the temperature alarm. If the temperature is below a set<br />

value between+5 and +30ºC, <strong>SMS</strong>-<strong>953</strong> will send an alarm to all phone numbers that have been<br />

programmed. The factory setting upon delivery and the default setting is +5ºC.<br />

<strong>SMS</strong>: tEMP 05~30 (E.g. TEMP 09) = Send an alarm when the temperature is below +9ºC<br />

nB! If there is a temperature adjustment, <strong>SMS</strong>-<strong>953</strong> will take it into consideration when sending<br />

an alarm.<br />