Drying<br />
Drying mode where the temperature can be set in steps in the range from +16 to +30ºC.<br />
The following is used as standard for new registrations: fan speed: 3, air swing: 1<br />
<strong>SMS</strong>: DRY 16~30 (E.g. DRY 18) = Drying +18ºC<br />
NB! Check the drain hose of the heat pump before operation.<br />
Fan Speed<br />
Change the fan speed regardless of the operating mode in steps from 0 to 5.<br />
0=auto, 1-5 are different speed steps where 1=lowest speed and 5=highest speed<br />
<strong>SMS</strong>: FanS 0~5 (E.g. FANS 3) = Fan speed level 3<br />
air Swing<br />
Change air swing regardless of the operating mode in steps from 0 to 5.<br />
0=Auto, 1-5 are directions in different steps where 1=Horizontal and 5=Vertical<br />
<strong>SMS</strong>: aiRS 0~5 (E.g. AIRS 2) = Air Swing level 2<br />
Start / Stop<br />
Start or stop the heat pump operation. When restarted the heat pump always starts in<br />
the last used operating mode before the pump was stopped; this applies also in case of<br />
power failure.<br />
<strong>SMS</strong>: On (E.g. ON) = Starts the heat pump<br />
<strong>SMS</strong>: OFF (E.g. OFF) = Stops the heat pump<br />
* The command works only on heat pump models equipped with this function.<br />
Please see the operation manual to find out what the functions of your model are.<br />
temperature Readings<br />
The remote control has a built-in sensor that senses ambient temperature.<br />
For optimum temperature sensing, the remote control must never be placed close to the<br />
front of the heat pump, nor should the sensor be covered since it would then be disturbed by<br />
temperature fluctuations. With a text message the user can find out what the current<br />
temperature in the place where <strong>SMS</strong>-<strong>953</strong> is installed is.<br />
<strong>SMS</strong>: tgEt (E.g. TGET) = Current temperature status<br />
(E.g. Received <strong>SMS</strong>: ”Confirm TMP:21C ADJ:+05TGET” = +21ºC with +0.5ºC adjustment)<br />
temperature adjustment<br />
If the temperature readings are misleading due to the location of the unit, it is possible to<br />
adjust the readings so that they complies with one’s own measurements.<br />
<strong>SMS</strong>: taDJ XYY (E.g. TADJ 120) = Negative correction of -2,0ºC<br />
X = 0 for a positive value, X = 1 for a negative value<br />
YY = 05 / 10 / 15 / 20 / 25 / 30 / 35<br />
(Ex. 05=0.5ºC / 10=1.0ºC / 15=1.5ºC / 20=2.0ºC / 25=2.5ºC / 30=3.0ºC / 35=3.5ºC)<br />
temperature alarms<br />
Change the temperature value set for the temperature alarm. If the temperature is below a set<br />
value between+5 and +30ºC, <strong>SMS</strong>-<strong>953</strong> will send an alarm to all phone numbers that have been<br />
programmed. The factory setting upon delivery and the default setting is +5ºC.<br />
<strong>SMS</strong>: tEMP 05~30 (E.g. TEMP 09) = Send an alarm when the temperature is below +9ºC<br />
nB! If there is a temperature adjustment, <strong>SMS</strong>-<strong>953</strong> will take it into consideration when sending<br />
an alarm.<br />