Assembly<br />
1. Take the gate out of it’s carrying bag.<br />
2. The gate unfolds by pulling top and bottom parts<br />
away from each other.<br />
2a. Important: Make sure that the sides are<br />
completely unfolded. The locks in either side (under<br />
the printed marks) must "click" for correct unfold.<br />
3. Place the gate in the opening. The top and<br />
bottom horizontal tubes are telescopic so that the<br />
gate can be adjusted to fit the opening by pushing<br />
the childproof locks (b and c) underneath the fabric.<br />
Important: The top and bottom tubes must be<br />
adjusted alternately. If not the gate can become<br />
skewed.<br />
4. Important: On the spindles at top (f) and bottom<br />
(h) (opposite the handle) is a red and yellow indicator.<br />
The function of the indicators is to show<br />
wheather the gate is correctly fitted or not. If the<br />
gate is correctly fitted neither the red or the yellow<br />
parts of the indicator are visible. If the red part of<br />
the indicators is visible the gate should not be fitted<br />
in this particular opening, because this means that<br />
the opening is unable to withstand the minimum<br />
pressure required for a safe installation.<br />
If only the yellow parts of the indicators are visible<br />
the gate shall be fitted with the provided wallcups<br />
(see ill.11).<br />
5. Using the telescope adjustment extend the gate<br />
as wide as possible to still allow the gate to fit ín<br />
the opening.<br />
Final adjustment will take place later. At the bottom<br />
the distance between the gate and the wall/door<br />
opening shall be no more than approx. 5 mm<br />
(2/10”) .<br />
6. Raise the gate to an upright position and press<br />
carefully the gate towards the floor until the bottom<br />
lock (g) is fully engaged (6a.). Check that neither the<br />
red or yellow part of the indicator is visible. If it is<br />
adjust the spindle opposite the bottom lock a little<br />
further out and position the gate and lock.<br />
7. Open the handle (e) by pushing the button whilst<br />
lifting the handle at the same time.<br />
7a+b. Adjust the top spindle (f) until it touches the<br />
wall. Adjust the spindle in the handle until the gap<br />
between the spindle and the wall is approx. 5mm<br />
(2/10").<br />
8. Close the handle. Check that neither the red or<br />
the yellow part of the indicator is visible . If they are<br />
go back to ill. 7a+b and adjust spindle further out.<br />
If the further adjustment fails to make the red<br />
marking disappear the gate is not suitable for this<br />
opening. If only the yellow marking is visible use<br />
provided wallcups (ill.11).<br />
9. If neither one of the indicators show the yellow<br />
part the gate is nearly fitted.<br />
Now adjust the locknuts towards the gate on both<br />
top and bottom spindles and tightens as tight as<br />
possible with your fingers. The gate is now ready<br />
to use.<br />
10. To remove the gate from the opening press<br />
button (d) in handle and open handle and lift the<br />
gate out of the opening. For re-installation place<br />
bottom part of gate towards the floor, raise gate<br />
upright and press gently towards the floor. Place<br />
top part of gate in a full upright position and close<br />
handle, the gate is now secure.<br />
11. If Indicators show yellow marking:<br />
Use the provided wallcups.<br />
Place top wall cups between the top spindles and<br />
the wall/door frame and bottom wall cups<br />
between the bottom spindles and the wall/door<br />
frame. Make sure that the bottom lock is fully<br />
engaged before placing wall cups, see ill. 6a).<br />
12. Mark out their position. Remove gate.<br />
13. Screw in wall cups according to markings.<br />
Note: The screws provided are only intended for<br />
fixing into wood. If fixing to other material, use<br />
appropriate screws and wallplugs (diameter = 4<br />
mm).<br />
14. Now you are reeady to install the gate<br />
according to ill. 5-9.<br />
15. Important: When the gate is correctly fitted<br />
with or without wall cups the distance between the<br />
wall and the outermost member of the gate must<br />
not exceed 55 mm (2.2”).<br />
16. Folding the gate<br />
When gate is no longer needed, it can be stored in<br />
its carrying bag.<br />
Remove gate from opening and close handle. Push<br />
button on top rail and slide sections together to the<br />
next smallest width.<br />
Repeat for bottom rail and alternate bottom and<br />
top rails until smallest gate width is achieved. It<br />
may also be necessary to retract spindles.<br />
Release locks (i) are located in middle of each side,<br />
indicated by printed icons on fabric. Doing one<br />
side at a time, squeeze lock while gently pressing<br />
inward. Repeat on second side.<br />
When collapsed, top and bottom plastic hinges will<br />
be touching.<br />
Gate can now be placed in carrying bag.