Laget for<br />

deg <strong>som</strong><br />

vil legge<br />

et rimelig<br />

pent,<br />

enkelt og<br />

holdbart<br />

TAK<br />

selv...<br />

1


ONDULINE TECHNIC AL BOOK<br />

2<br />

1<br />

MONTERINGS DETALJER<br />

LEGGE ANVISNING<br />

OVERLAPPINGS REGLER<br />

Takvinkel ved > 18°<br />

Maksimum 372 mm<br />

lekteavstand c/c<br />

Maksimum overheng 50 mm<br />

Minimum overlapp 140 mm<br />

i skjøter<br />

Minimum overlapp 1 bølge<br />

sideveis<br />

n PLATER<br />

1 - Start legging av plater fra motsatt side på taket av<br />

den fremherskende vindretning.<br />

2 - For best mulig resultat legges platene med forskjøvet<br />

opplegg ved å starte rad nr. 2 med en delt plate på<br />

langs.<br />

3 - Ved takfot anbefales å legge dobbelt lag med<br />

Onduline. En remse på 100 mm på <strong>ned</strong>erste lekte,<br />

eller et kapp på 500 mm på <strong>ned</strong>erste 2 lekter legges<br />

uten overlapping. Dette vil styrke taket der hvor<br />

platene er mest sårbar.


TAKKONSTRUKSJON MED TAKVINKEL MINIMUM 18º<br />

n KONSTRUKSJON<br />

For tak over 18 graders takehelling skal Onduline legges på<br />

lekter med c/c avstand på maksimum 372 mm.<br />

For avvik, www.onduline.no se monteringsforskrifter.<br />

n OVERLAPPING<br />

- Overlapping endeveis minimum 140 mm.<br />

- Overlapping sideveis minimum 1 bølge.<br />

Ved ugunstige værforhold må overlapping vurderes.<br />

n DIMENSJONER PÅ FRITTBÆRENDE LEKTER<br />

- Avstand mellom åser / sperrer c/c 600 mm 1200 mm<br />

- Lekter c/c 372 mm 30x48 mm 48x48 mm<br />

n STIFTING<br />

Platene stiftes med hammer. Stiftes i bølgetopp.<br />

Vær nøye og du får et fint resultat<br />

- 21 stift skal monteres pr plate 2000x950 mm<br />

- Hver bølgetopp skal stiftes ved takfot, møne og<br />

overlapping.<br />

Da Onduline er en fleksibel plate er det viktig å følge<br />

<strong>ned</strong>enstående stiftanvisning.<br />

Kapping<br />

Plater og møner kappes best med en grovtannet sirkelsag.<br />

Pass på å tømme sagen ofte for asfalt. Husk å trekke ut<br />

støpselet ved rengjøring.<br />

3


ONDULINE TECHNIC AL BOOK<br />

4<br />

MØNER<br />

MONTERINGS DETALJER<br />

1 - Bruk alltid stående kantbord under møne.<br />

2 - Mønet skal stiftes gjennom hver bølgetopp på underliggende plate.<br />

3 - Bruk en ekstra lekte for korrekt avstand til mønet.<br />

4 - Start montering av møne fra motsatt side på taket fra den fremherskende vindretning.<br />

5 - Overlapping mellom plate og møne skal være 120 mm.<br />

6 - Minimum 125 mm overlapping endeveis.<br />

7 - Et mønelokk kan skjæres ut av<br />

f. eks. vannfast kryssfiner.


AVSLUTNINGER<br />

n AVSLUTNING MED EN BøLGE<br />

AV ONDULINE<br />

1 - Legg en bølge oppå kantbordet.<br />

2 - Bøy platen <strong>ned</strong> og fest til kantbord.<br />

n AVSLUTNING MED VINDSKI<br />

AV TRyKKIMPREGNERT VANN-<br />

BORD<br />

n AVSLUTNING MED ONDULINE<br />

VANNBORD BESLAG.<br />

n AVSLUTNING MED VANNBORD<br />

BESLAG AV STÅL ELLER<br />

LIGNENDE.<br />

TAKFOT / TAKSKJEGG<br />

Onduline skal maksimum stikke 50<br />

mm utover <strong>ned</strong>erste lekte.<br />

Ved takfot anbefales å legge<br />

dobbelt lag med Onduline. En<br />

remse på 100 mm på <strong>ned</strong>erste<br />

lekte, eller et kapp på 500 mm<br />

på <strong>ned</strong>erste 2 lekter legges uten<br />

overlapping.<br />

Dette vil styrke taket der hvor<br />

platene er mest sårbar.<br />

5


ONDULINE TECHNIC AL BOOK<br />

6<br />

AVSLUTNING MOT VEGG<br />

n ONDULINE<br />

PRODUSERER EGEN<br />

AVSLUTNINGSSPROFIL<br />

TILPASSET ONDULINE.<br />

Det finnes flere alternativer for<br />

avslutning mot vegg.<br />

Det vanligste er å legge<br />

vannbordbeslag under kledning<br />

og ut over Onduline platene.<br />

Onduline tetningslist kan legges<br />

under vannbordsbeslag.<br />

ONDULINE OVERLYSPLATER<br />

- Onduline PVC leveres i klar<br />

eller matt utførelse.<br />

Platene festes på samme måte<br />

<strong>som</strong> vanlig Onduline plate.<br />

Husk å forborre hullene før de<br />

spikres for å unngå sprekk i plate.<br />

2 - INSTALLATION MONTERINGS DETALJER<br />

DETAILS


TAKSTEIN EFFEKT<br />

Onduline kan monteres <strong>som</strong> vist på bilde. Kutt platene i 4 deler, 500x950 mm.<br />

Når Onduline monteres med takstein effekt må lekteavstanden reduseres til c/c 360 mm.<br />

Husk å spikre på hver bølgetopp.<br />

7


2TEKNISKE<br />

DATA ONDULINE<br />

ONDULINE TECHNIC AL BOOK<br />

8<br />

PRODUKT SPESIFIKASJONER<br />

Plater PP/HR: Plater PVC: Møner:<br />

Lengde 2000 mm 2000 mm 1000 mm<br />

Bredde 950 mm 950 mm 180 mm (fra vinkelbrytning)<br />

Dekkbredde 855 mm 855 mm<br />

Tykkelse 3,0 mm 1,2 mm 3,0 mm<br />

Vekt 6,3 kg/plate 3,5 kg/plate 1,3 kg<br />

Bølgehøyde 38 mm 38 mm<br />

Farger; sort, rød, grønn og brun klar og matt sort, rød, grønn og brun<br />

Stift: Forbruk stift:<br />

Poser à 400 stk Tak, pr. plate 21 stk<br />

Lengde 70 mm Vegg, pr. plate 18 stk<br />

Tykkelse 3 mm Møne pr. stk 18 stk<br />

Kvalitet galvanisert<br />

Farger PVC hode sort, rød, grønn, brun.<br />

Onduline er produsert etter standard NF EN ISO 14001: 1996<br />

Onduline er en ekstrem tøff og lett profilert tak- og veggplate.<br />

Platen er produsert av organiske fibre gjennommettet av bitumen under intens trykk og varme.<br />

Onduline er ugjennomtrengelig for vann og er garantert 20 år i Norge mot vanngjennomgang og 10 år mot farveavskalling.<br />

Onduline er fri for asbest og giftige stoffer.<br />

Onduline er fleksibel og økonomisk.<br />

Onduline PP/HR flasser ikke, ruster ikke lekker ikke.<br />

Onduline PP/HR er stormsikker, frostsikker, støydempende, kondenshindrene og fleksibel.<br />

Onduline PP/HR tåler saltvann, kjemiske gasser, trakk på taket og beskyttet utelagring.<br />

Onduline PP/HR monteres på selvbærende lekter, radius <strong>ned</strong> til 5 meter.<br />

Onduline PP/HR anvendes <strong>som</strong> takkledning, veggkledning, diffusjonstett undertak, støyskjerm.<br />

ONDULINE PP/HR PLATE<br />

n 2000 x 950 MM LEVERES I FARGENE:<br />

SORT, RøD, GRøNN OG BRUN.<br />

ONDULINE PP/HR MØNE<br />

n 1000 MM x 180


3<br />

VENTILASJON<br />

TAK VENTILASJON<br />

vær nøye med venTilasjon. Unngå kondensering og dens konsekvenser.<br />

Hvor forskriftsmessig taktekking gjelder, skal undertak<br />

anvendes.<br />

Under lektene skal der være minimum 13 mm sløyfer for<br />

at vannet skal renne av.<br />

Der<strong>som</strong> taklengde på hver side ikke overstiger 10 meter,<br />

er ventilasjon av undertak ved takfot og møne tilstrekkelig.<br />

Onduline-tak skal i likhet med alle andre takkonstruksjoner<br />

utføres med tilstrekkelig utlufting av takflatens underside,<br />

slik at der ikke oppstår eventuell skadelig kondens.<br />

I den enkelte bygning avhenger kravet til ventilasjon<br />

av bygningens formål, plassering og eventuell isolering,<br />

dampsperre, takets helling osv.<br />

Normalt vil ventilasjonsåpninger med et samlet takareal på<br />

1/250 del av takets flate være tilstrekkelig.<br />

Ved åpning i takkisten langs bygget strømmer luft inn. Ved<br />

mønet presses luften ut.<br />

Der må kun anvendes tetningsremser ved takfot og møne<br />

<strong>som</strong> ”puster”<br />

9


4 SERTIFIKATER<br />

TESTER OG GODKJENNINGER<br />

ONDULINE TECHNIC AL BOOK<br />

10<br />

ZESPOL CERTYFIKACH<br />

WYROBOW I USLUG<br />

BUDOWLANYCH<br />

R<br />

BRITISH<br />

BOARD OF BBA AGREMENT<br />

ASSEMENT OF PRODUCT FOR CONSTRUCTION<br />

Designated by Goverment<br />

to issue<br />

European Technical<br />

Approvals<br />

Strength and Impact Loading<br />

Warrington Research Laboratory Test (UK)<br />

BS1811.<br />

United States Testing Co. ASTMD 1502-60<br />

CEBTP (France): Report no 2342.7.098<br />

Bureau Veritas (France): BTE JPD / NC 1016 /<br />

1995<br />

CSTB: NO GM/92-20<br />

Test showed adequated bearing strength, impact<br />

resistance and resistance to wind lift<br />

Mechanical Strength<br />

Warrington Research Laboratory Test (UK)<br />

BS4154.<br />

Showed resistance to 73lbs sheered force on fixing<br />

bolt.<br />

Water Absorption<br />

Warrington Research Laboratory Test (UK)<br />

BS1811.<br />

Showed minimal absorption.<br />

ASTM E96 (USA). Performed excellently in<br />

moisture vapour transmission and showed only<br />

minimal absorption.<br />

DIN 52103 (Germany) Showed no effects after 16<br />

days when immersed.<br />

Heat Deformation<br />

Warrington Research Laboratory Test (UK).<br />

Tropical investigation test showed no visible effects.<br />

Yarsley Research Centre Test (UK)<br />

Middle east suitability tets up to 70OC proved<br />

complete suitability in severe humidity and under all<br />

foreseeable conditions.<br />

Thermal Resistance (Insulation)<br />

ASTM C177-76 (USA) and BS874 (UK).<br />

Showed excellent thermal resistance<br />

K value 0.46 to 0.51 British Thermal Unit<br />

LNE (France): Certificate NO 7070916 D MAT/1<br />

Thermal conductivity : 0.099W/mK<br />

• CSTB (France). AT 5/04/1779. AT 5/03/1690.<br />

AT 5/9 1424<br />

• CSTC / Ubatc (Belgium): ATG 01/1938<br />

• BBA (UK): A.C.87/1823 C<br />

• ITB (Poland): 500 / 02 AT 1 2145 / 2002<br />

• BRANZ (Australia): AC 02/2004<br />

• BRANZ (New Zealand): AC 432 (2002)<br />

• Conformity to EN 534 general performance and attitude tests<br />

• ISO 9001:2000<br />

• ISO 14001<br />

Water and Weather Proofing<br />

Tests (UK) BS1811 and ASTM D1499 (USA).<br />

UIDIEM (Chile): Certificate NO 150 385<br />

Test showed excellent weather-proofing<br />

charactheristic<br />

Wind Lift<br />

Yarsley Research Centre (UK). Proved Onduline<br />

suitable in hurricane and earthquake conditions.<br />

Tested up to 120 mph (192kph)<br />

Building Researh Establishment (UK): NO<br />

BRE/83/11/1<br />

Good behavior in wind lift conditions<br />

Wood Technology Division (New Zealand):<br />

NO WTC 1468/2 Good behaviour in cyclonic<br />

conditions<br />

Minister of Economic (Argentina): NO 83-1<br />

INPRES 95 & PV NO 030 DPDU-95<br />

Hail / Frost Resistance<br />

ASTM E196 (USA) and DIN 52103 dan 52104<br />

(Germany).<br />

Meets snow and frost resistance for all regions.<br />

No mechanical damage in frost<br />

Toxicity and resistance to chemicals Test<br />

Yarsley Research Centre (UK)<br />

Tests carried out on water collected after<br />

catchments with Onduline sheets give water<br />

suitable for drinking complying with World Health<br />

Organization and EEC regulations.<br />

CSTB (France): NO SM/98-0062<br />

Good behaviour under exposure to acids, alkalis,<br />

and salts.<br />

Acoustical Insulation<br />

CEBTP No 2312.6.244/1<br />

Reverberation coefficient (max): 0.4 to 315 Hz<br />

CSTB C/95/CL/1896/1<br />

Sound attenuation coefficient (max) : Rw = 28 dB<br />

Wolfson unit Southampton University (UK).<br />

NO 2089 1592/B1 : Antenoise wall with Onduline<br />

reduces the airborne noises of 7 dB


5<br />

GENERELL INFORMASJON<br />

Levering og oppbevaring<br />

Onduline leveres fra fabrikk på profilerte paller og<br />

bør oppbevares slik, på flat underlag og tildekket med<br />

presenning, inntil montering. Om <strong>som</strong>meren vil platene<br />

ved direkte påvirkning av solvarme klebe sammen. Unngå<br />

dette ved å lagre platene i skyggen.<br />

Håndtering<br />

Platenes lette vekt gjør transport til byggeplass enkel.<br />

Minimal brekkasje under transport.<br />

Onduline er lett å håndtere på grunn av at platen her<br />

ingen skarpe kanter.<br />

Teknisk service<br />

Onduline har til rådighet en omfattende teknisk stab for<br />

råd og spørsmål om produktene.<br />

Monteringsanvisninger er tilgjengelig på de fleste språk,<br />

men kun norsk leggeanvisning skal anvendes i Norge.<br />

Ombruk / trekke ut en stift<br />

Skal Onduline fjernes for å monteres på nytt et annet sted<br />

må stift fjernes.<br />

Den enkleste metoden er å bruke et rundt trestykke <strong>som</strong><br />

legges <strong>ned</strong> i bølgebunn.<br />

Hammer eller brekkjern presses forsiktig inn mellom stift<br />

og plate og stiften trekkes ut ved at motholdet hviler mot<br />

treklossen.<br />

Forholdsregler<br />

Når Onduline skal benyttes i svært fuktige miljøer må<br />

undertak monteres.<br />

Sørg for ekstra god ventilasjon.<br />

Ved montering av Onduline sørg for at Helse Miljø og<br />

Sikkerhet alltid er tilstede.<br />

Vedlikehold<br />

For å opprettholde lang levetid av Onduline skal følende<br />

vedlikehold gjennomføres:<br />

- La ikke løv og kvister bygge seg opp på taket. Dette vil<br />

på sikt kunne bløtgjøre platene da de ikke for tørke ut<br />

mellom regnperiodene.<br />

- Sjekk at grener ikke vokser seg inn på taket, disse kan<br />

medføre hull i platene.<br />

- Sørg for at takrenner, ventilasjon og skorsteiner er fri for<br />

løv og kvister.<br />

- Vurder om trær <strong>som</strong> står for nært huset bør fjernes for å<br />

hindre oppsamling av løv.<br />

Salgsbetingelser<br />

Onduline PP/HR er en trykkimpregnert asfalt fiberplate<br />

med en innfargingsprosess (PP pre patinated). Farge<br />

impregneringen vil over tid endre seg på lik linje med<br />

tilsvarende tak produkter av natur materiale. Onduline<br />

påtar seg ingen ansvar <strong>som</strong> følger av konstruksjons<br />

endringer.<br />

Vi tar forbehold om endringer i spesifikasjoner og detaljer<br />

uten forvarsel.<br />

Alle henvendelser om råd og veiledning om Onduline må<br />

sendes skriftlig.<br />

Onduline er ikke testet og godkjent for andre formål<br />

der<strong>som</strong> dette ikke er skriftlig godkjent fra produsent.<br />

Ubetydelige fravik i størrelse, vekt og farge kan<br />

forekomme.<br />

HMS<br />

Fotografier og tegninger i denne brosjyre er hovedsakelig<br />

basert for norske forhold.<br />

Brosjyren er omarbeidet fra installasjoner fra hele verden.<br />

Bruker må selv sørge for at norske retningslinjer, praksis og<br />

sikkerhet til enhver tid følges.<br />

This Technical data folder has been prepared by OFIC SA and pursuant to the Intellectual and Artistic Works<br />

Law, its copyright, right of publication and all other relevant rights in any language and all over the world are reserved.<br />

None of the writings, photographs and drawings published in this manual may in no way be used, or quoted partially or<br />

wholly, without showing their source, nor they may be copied, multiplied or published.<br />

11


ONDULINE TECHNIC AL BOOK<br />

12<br />

AGENT FOR NORGE:<br />

Hamreveien 10<br />

5229 Kalandseidet<br />

Telefon: 5592 5700 - Telefaks: 5592 5709<br />

www.onduline .no e-post: mail@onduline.no<br />

ONDULINE<br />

35 rue Baudin 92300 LEVALLOIS-PERRET FRANCE<br />

Tel : +33 (0) 1 55 63 80 10<br />

Fax : +33 (0) 1 41 34 30 54<br />

www.onduline.com<br />

11/2009 - Foto : Groupe Onduline - Document non contractuel.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!