HDC-190, HDC-220TroubleshootingInterior temperature too low in control setting “1”Fault Possible cause RemedyCompressor runsconstantlyCompressor runs for along timeThermostat sensor has no contact tothe vaporiserShort circuit in the thermostat lineThermostat <strong>de</strong>fectiveLarge quantities have been frozen inthe freezer compartmentSecure the sensorChange the thermostat–Cooling capacity drops, interior temperature risesFault Possible cause RemedyCompressor runs for along time/continuouslyCompressor does notrun oftenVaporiser iced overDefrost the vaporiserCooling area insulation is insufficient(moist/wet)Adjust/replace the doorsealAmbient temperature too high –Insufficient ventilationMove the refrigeratorCon<strong>de</strong>nsor is dirtyClean the con<strong>de</strong>nsorFan <strong>de</strong>fective (if installed)Replace the fanBattery capacity exhaustedCharge the batteryUnusual noisesFault Possible cause RemedyLoud hummingA component of the refrigerant circuitcannot move freely (lies against thewall)Foreign body jammed between thecooling <strong>de</strong>vice and the wallFan noise (if installed) –Bend the componentcarefullyRemove the foreign body31