Sistemas <strong>de</strong> Detecção <strong>de</strong> Incêndio | <strong>FPE‑1000‑NF</strong> <strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>1‑Ethernet</strong> <strong>2‑Fibra</strong> <strong>óptica</strong><br />
<strong>FPE‑1000‑NF</strong> <strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>1‑Ethernet</strong><br />
<strong>2‑Fibra</strong> <strong>óptica</strong><br />
www.boschsecurity.com/pt<br />
A <strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>de</strong> Fibra Óptica <strong>FPE‑1000‑NF</strong> fornece<br />
duas portas <strong>de</strong> fibra <strong>óptica</strong> para comunicação ponto a<br />
ponto <strong>de</strong> entrada e saída e uma porta Ethernet<br />
adicional para comunicação com placas Ethernet e<br />
com fio, para reportes IP ou para programação <strong>de</strong><br />
painéis/re<strong>de</strong>s baseada no navegador.<br />
Funções<br />
Alimentação Auxiliar<br />
A placa <strong>de</strong> re<strong>de</strong> normalmente recebe alimentação da<br />
placa principal FPA‑1000‑V2. A placa <strong>de</strong> re<strong>de</strong> po<strong>de</strong>,<br />
entretanto, ser alimentada por uma fonte auxiliar (24<br />
VCC nominal com conector <strong>de</strong> 2 pinos). Quando<br />
ambas as fontes <strong>de</strong> alimentação estão conectadas à<br />
placa <strong>de</strong> re<strong>de</strong>, somente uma fonte fornece energia<br />
para a placa sem interferência com a outra fonte. Com<br />
isso, a re<strong>de</strong> po<strong>de</strong> continuar funcionando mesmo<br />
quando for preciso <strong>de</strong>sconectar a placa <strong>de</strong> re<strong>de</strong> da<br />
placa principal para fins <strong>de</strong> manutenção.<br />
u Fornece alteração do tipo <strong>de</strong> mídia com conexões<br />
RJ45 e <strong>de</strong> fibra <strong>óptica</strong><br />
u Fornece uma porta Ethernet usando cabo CAT 5 ou<br />
melhor<br />
u Utiliza conexão plug-in simples com o FPA‑1000‑V2<br />
u Conecta-se como Classe A ou Classe B<br />
u Fornece uma segunda porta <strong>de</strong> entrada <strong>de</strong><br />
alimentação para operação normal da re<strong>de</strong> durante<br />
a manutenção<br />
Certificados e Aprovações<br />
Região Certificação<br />
EUA UL FSZI.S1871: Emergency Alarm System<br />
Control Units (ANSI/UL 2017); UOJZ:<br />
Control Units, System (ANSI/UL 864)<br />
Planeamento<br />
CSFM 7165-1615:0229 Unida<strong>de</strong> <strong>de</strong> Controle<br />
<strong>de</strong> Alarme <strong>de</strong> Incêndio (Comercial)<br />
FDNY-<br />
-CoA<br />
#6101<br />
Instalação<br />
Instale a placa <strong>de</strong> re<strong>de</strong> na parte <strong>de</strong> baixo do teclado da<br />
placa principal. Os cabos <strong>de</strong> cobre na placa <strong>de</strong> re<strong>de</strong> se<br />
encaixam nos terminais na placa principal e o suporte<br />
da placa <strong>de</strong> re<strong>de</strong> se encaixa no lugar sobre a base do<br />
teclado.<br />
Conexões<br />
Todas as conexões Ethernet são feitas com pelo<br />
menos um cabo CAT 5 com comprimento máximo <strong>de</strong><br />
100 m (328 pés). As conexões <strong>de</strong> fibra <strong>óptica</strong> são<br />
feitas com cabo <strong>de</strong> fibra <strong>óptica</strong> multimodo (tamanho<br />
da fibra 62,5 μm/125 μm; comprimento <strong>de</strong> onda <strong>de</strong>
2 | <strong>FPE‑1000‑NF</strong> <strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>1‑Ethernet</strong> <strong>2‑Fibra</strong> <strong>óptica</strong><br />
1270 nm a 1380 nm) com conectores LC com<br />
comprimento máximo <strong>de</strong> 2000 m (6560 pés ou perda<br />
<strong>de</strong> 10 db, o que ocorrer primeiro).<br />
Peças incluídas<br />
Quant. Componente<br />
1 <strong>Placa</strong> <strong>de</strong> re<strong>de</strong> com suporte <strong>de</strong> fixação acoplado<br />
2 Literatura:<br />
• Manual <strong>de</strong> Instalação das <strong>Placa</strong>s <strong>de</strong> Re<strong>de</strong><br />
• Guia <strong>de</strong> Instalação Rápida <strong>de</strong> Re<strong>de</strong>s<br />
Especificações Técnicas<br />
Especificações Elétricas<br />
Corrente: 170 mA máximo<br />
Tensão (fornecida pela placa principal<br />
FPA‑1000 e/ou fonte <strong>de</strong> alimentação<br />
auxiliar com conector <strong>de</strong> 2 pinos):<br />
Aspectos Ambientais<br />
Ambiente: Interno, seco<br />
Nominal: 24 VCC<br />
Faixa: 20 VCC a 28 VCC<br />
Umida<strong>de</strong> Relativa: Até 95%, sem con<strong>de</strong>nsação<br />
Temperatura (operação): 0 °C a +49 °C (+32 °F a +120 °F)<br />
Especificações Mecânicas<br />
Conexão Ethernet<br />
• Tipo <strong>de</strong> Conector: Cabo CAT 5 mínimo<br />
• Distância do Circuito: 100 m (328 pés) máximo<br />
Conexão <strong>de</strong> fibra <strong>óptica</strong><br />
• Tipo <strong>de</strong> conector: Fibra <strong>óptica</strong> multimodo com<br />
conector LC; tamanho da fibra<br />
62,5 μm/125 μm; 1270 nm a<br />
1380 nm <strong>de</strong><br />
comprimento <strong>de</strong> onda<br />
• Distância do Circuito: 2000 m (6560 pés) ou perda<br />
máxima <strong>de</strong> 10 db<br />
Como encomendar<br />
<strong>FPE‑1000‑NF</strong> <strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>1‑Ethernet</strong> <strong>2‑Fibra</strong> <strong>óptica</strong><br />
<strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>de</strong> Fibra Óptica para comunicação<br />
ponto a ponto em um sistema FPA‑1000 em re<strong>de</strong><br />
N.º <strong>de</strong> encomenda FPE-1000-NF<br />
Representado por:<br />
Portugal: America Latina:<br />
<strong>Bosch</strong> Security Systems<br />
Sistemas <strong>de</strong> Segurança, SA.<br />
Av. Infante D.Henrique, Lt.2E - 3E<br />
Apartado 8058<br />
Lisboa, 1801-805<br />
Telefone: +351 218 500 360<br />
Fax: +351 218 500 088<br />
pt.securitysystems@bosch.com<br />
www.boschsecurity.com/pt<br />
Robert <strong>Bosch</strong> Ltda<br />
Security Systems Division<br />
Via Anhanguera, Km 98<br />
CEP 13065-900<br />
Campinas, Sao Paulo, Brazil<br />
Phone: +55 19 2103 2860<br />
Fax: +55 19 2103 2862<br />
al.securitysystems@bosch.com<br />
www.boschsecurity.com<br />
© <strong>Bosch</strong> Security Systems 2012 | Dados sujeitos a alteração sem aviso prévio.<br />