18.04.2013 Views

FPE‑1000‑NF Placa de Rede 1‑Ethernet 2‑Fibra óptica - Bosch

FPE‑1000‑NF Placa de Rede 1‑Ethernet 2‑Fibra óptica - Bosch

FPE‑1000‑NF Placa de Rede 1‑Ethernet 2‑Fibra óptica - Bosch

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Sistemas <strong>de</strong> Detecção <strong>de</strong> Incêndio | <strong>FPE‑1000‑NF</strong> <strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>1‑Ethernet</strong> <strong>2‑Fibra</strong> <strong>óptica</strong><br />

<strong>FPE‑1000‑NF</strong> <strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>1‑Ethernet</strong><br />

<strong>2‑Fibra</strong> <strong>óptica</strong><br />

www.boschsecurity.com/pt<br />

A <strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>de</strong> Fibra Óptica <strong>FPE‑1000‑NF</strong> fornece<br />

duas portas <strong>de</strong> fibra <strong>óptica</strong> para comunicação ponto a<br />

ponto <strong>de</strong> entrada e saída e uma porta Ethernet<br />

adicional para comunicação com placas Ethernet e<br />

com fio, para reportes IP ou para programação <strong>de</strong><br />

painéis/re<strong>de</strong>s baseada no navegador.<br />

Funções<br />

Alimentação Auxiliar<br />

A placa <strong>de</strong> re<strong>de</strong> normalmente recebe alimentação da<br />

placa principal FPA‑1000‑V2. A placa <strong>de</strong> re<strong>de</strong> po<strong>de</strong>,<br />

entretanto, ser alimentada por uma fonte auxiliar (24<br />

VCC nominal com conector <strong>de</strong> 2 pinos). Quando<br />

ambas as fontes <strong>de</strong> alimentação estão conectadas à<br />

placa <strong>de</strong> re<strong>de</strong>, somente uma fonte fornece energia<br />

para a placa sem interferência com a outra fonte. Com<br />

isso, a re<strong>de</strong> po<strong>de</strong> continuar funcionando mesmo<br />

quando for preciso <strong>de</strong>sconectar a placa <strong>de</strong> re<strong>de</strong> da<br />

placa principal para fins <strong>de</strong> manutenção.<br />

u Fornece alteração do tipo <strong>de</strong> mídia com conexões<br />

RJ45 e <strong>de</strong> fibra <strong>óptica</strong><br />

u Fornece uma porta Ethernet usando cabo CAT 5 ou<br />

melhor<br />

u Utiliza conexão plug-in simples com o FPA‑1000‑V2<br />

u Conecta-se como Classe A ou Classe B<br />

u Fornece uma segunda porta <strong>de</strong> entrada <strong>de</strong><br />

alimentação para operação normal da re<strong>de</strong> durante<br />

a manutenção<br />

Certificados e Aprovações<br />

Região Certificação<br />

EUA UL FSZI.S1871: Emergency Alarm System<br />

Control Units (ANSI/UL 2017); UOJZ:<br />

Control Units, System (ANSI/UL 864)<br />

Planeamento<br />

CSFM 7165-1615:0229 Unida<strong>de</strong> <strong>de</strong> Controle<br />

<strong>de</strong> Alarme <strong>de</strong> Incêndio (Comercial)<br />

FDNY-<br />

-CoA<br />

#6101<br />

Instalação<br />

Instale a placa <strong>de</strong> re<strong>de</strong> na parte <strong>de</strong> baixo do teclado da<br />

placa principal. Os cabos <strong>de</strong> cobre na placa <strong>de</strong> re<strong>de</strong> se<br />

encaixam nos terminais na placa principal e o suporte<br />

da placa <strong>de</strong> re<strong>de</strong> se encaixa no lugar sobre a base do<br />

teclado.<br />

Conexões<br />

Todas as conexões Ethernet são feitas com pelo<br />

menos um cabo CAT 5 com comprimento máximo <strong>de</strong><br />

100 m (328 pés). As conexões <strong>de</strong> fibra <strong>óptica</strong> são<br />

feitas com cabo <strong>de</strong> fibra <strong>óptica</strong> multimodo (tamanho<br />

da fibra 62,5 μm/125 μm; comprimento <strong>de</strong> onda <strong>de</strong>


2 | <strong>FPE‑1000‑NF</strong> <strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>1‑Ethernet</strong> <strong>2‑Fibra</strong> <strong>óptica</strong><br />

1270 nm a 1380 nm) com conectores LC com<br />

comprimento máximo <strong>de</strong> 2000 m (6560 pés ou perda<br />

<strong>de</strong> 10 db, o que ocorrer primeiro).<br />

Peças incluídas<br />

Quant. Componente<br />

1 <strong>Placa</strong> <strong>de</strong> re<strong>de</strong> com suporte <strong>de</strong> fixação acoplado<br />

2 Literatura:<br />

• Manual <strong>de</strong> Instalação das <strong>Placa</strong>s <strong>de</strong> Re<strong>de</strong><br />

• Guia <strong>de</strong> Instalação Rápida <strong>de</strong> Re<strong>de</strong>s<br />

Especificações Técnicas<br />

Especificações Elétricas<br />

Corrente: 170 mA máximo<br />

Tensão (fornecida pela placa principal<br />

FPA‑1000 e/ou fonte <strong>de</strong> alimentação<br />

auxiliar com conector <strong>de</strong> 2 pinos):<br />

Aspectos Ambientais<br />

Ambiente: Interno, seco<br />

Nominal: 24 VCC<br />

Faixa: 20 VCC a 28 VCC<br />

Umida<strong>de</strong> Relativa: Até 95%, sem con<strong>de</strong>nsação<br />

Temperatura (operação): 0 °C a +49 °C (+32 °F a +120 °F)<br />

Especificações Mecânicas<br />

Conexão Ethernet<br />

• Tipo <strong>de</strong> Conector: Cabo CAT 5 mínimo<br />

• Distância do Circuito: 100 m (328 pés) máximo<br />

Conexão <strong>de</strong> fibra <strong>óptica</strong><br />

• Tipo <strong>de</strong> conector: Fibra <strong>óptica</strong> multimodo com<br />

conector LC; tamanho da fibra<br />

62,5 μm/125 μm; 1270 nm a<br />

1380 nm <strong>de</strong><br />

comprimento <strong>de</strong> onda<br />

• Distância do Circuito: 2000 m (6560 pés) ou perda<br />

máxima <strong>de</strong> 10 db<br />

Como encomendar<br />

<strong>FPE‑1000‑NF</strong> <strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>1‑Ethernet</strong> <strong>2‑Fibra</strong> <strong>óptica</strong><br />

<strong>Placa</strong> <strong>de</strong> Re<strong>de</strong> <strong>de</strong> Fibra Óptica para comunicação<br />

ponto a ponto em um sistema FPA‑1000 em re<strong>de</strong><br />

N.º <strong>de</strong> encomenda FPE-1000-NF<br />

Representado por:<br />

Portugal: America Latina:<br />

<strong>Bosch</strong> Security Systems<br />

Sistemas <strong>de</strong> Segurança, SA.<br />

Av. Infante D.Henrique, Lt.2E - 3E<br />

Apartado 8058<br />

Lisboa, 1801-805<br />

Telefone: +351 218 500 360<br />

Fax: +351 218 500 088<br />

pt.securitysystems@bosch.com<br />

www.boschsecurity.com/pt<br />

Robert <strong>Bosch</strong> Ltda<br />

Security Systems Division<br />

Via Anhanguera, Km 98<br />

CEP 13065-900<br />

Campinas, Sao Paulo, Brazil<br />

Phone: +55 19 2103 2860<br />

Fax: +55 19 2103 2862<br />

al.securitysystems@bosch.com<br />

www.boschsecurity.com<br />

© <strong>Bosch</strong> Security Systems 2012 | Dados sujeitos a alteração sem aviso prévio.<br />

2691302923 | pt, V3, 14. Set 2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!