24.06.2014 Views

XIII Encontro Nacional de Física de Partículas e Campos.pdf

XIII Encontro Nacional de Física de Partículas e Campos.pdf

XIII Encontro Nacional de Física de Partículas e Campos.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

- 07 EFEITOS DA BLINDAGEM (Pb) NOS mODuLos. DETETORES DO EXPER'I-<br />

MENTO EASCAMP.<br />

A.R.P.Siral, J.A.Chinellato, A.C.Fauth, E.Kemp, M.A.Leigul O., H.Nogima, R.C.<br />

Rigitano, L.G.dos Santos, E.L.F. da Silva, N.M.Silva, I.C.Souza Jr., E.Tamura,<br />

A.Turtelli Jr. - Universida<strong>de</strong> Estadual -<strong>de</strong> Campinas - IFGW - DRCC.<br />

0 experimento EASCAMP '6 um <strong>de</strong>tetor <strong>de</strong> chuveiros atmosfericos extensos<br />

(CAE) formado por modulus <strong>de</strong> plasticos cintiladores e tubos "streamer". As<br />

direcaes <strong>de</strong> chegada dos CAE's, sae obtidas atraves da tecnica <strong>de</strong> tempo <strong>de</strong> vE50.<br />

Alguns cictiladores foram blindados cum chumbo, barrando assim os eletrons <strong>de</strong><br />

baixa energia da frente dos C.A.E. Sera() apresentados alguns efeitos <strong>de</strong>ssa<br />

blindagem nas medidas <strong>de</strong> dispersao temporal.<br />

P - 05<br />

A REFLEXIVE PHOTODENSITOMETRIC METHOD<br />

FOR STUDY OF NUCLEAR TRACK IN SOLID<br />

(Application to Cosmic Ray Physics)<br />

C.E.Navia, C.R.A.Augusto, F.A.Pinto and H.<strong>de</strong> Castro<br />

Institute <strong>de</strong> Fisica, Universida<strong>de</strong> Fe<strong>de</strong>ral Fluminense<br />

21020 Niteroi, RJ. Brasil<br />

E.H.Shibuya<br />

Instituto <strong>de</strong> Fisica, Universida<strong>de</strong> Estadual <strong>de</strong> Campinas<br />

13081 Campinas, SP. Brasil<br />

This paper report the "so called" reflexive photo<strong>de</strong>nsitometric<br />

method, for observation and study of nuclear track in solid, using a<br />

hand scanner with resolution of 400 dpi (dot per inch) and 256 gray<br />

scale.Special attention is gived to application for cosmic ray showers<br />

observed in emulsion chamber. The calibration, relation between the<br />

gray scale and the shower energy is discussed in <strong>de</strong>tail and some preliminary<br />

results are given to <strong>de</strong>mostrate the technique.<br />

- 09 TESTE DE EFICIENCIA "DE CARTOES LECROY 4200 PARA A EXPERIENCIA MICROSUL -<br />

COLABORA00 MICROSUL*<br />

0 telescOpio <strong>de</strong> muons Microsul, que esta sendo montado no IAG-USP, consta <strong>de</strong> 576 contaaores<br />

tipo "streamer" Iarocci, gerando 1152 sinais que'alimentam 36 cartoes, que constam <strong>de</strong> chips<br />

<strong>de</strong>dicados Mil-2000 e "shift registers" 4021. Um gerador <strong>de</strong> pulsos HP8112 simula o sinal dos<br />

tubos "streamer" e estudamcs a eficiencia dos cartoes em fungi° da largura e amplitu<strong>de</strong> dos<br />

pulsos e do limier do chip. Os xesultados iniciais mostram limites <strong>de</strong> funcionamento dos car<br />

ties diferentes <strong>de</strong>s especificacOes: pulsos <strong>de</strong> largura superior a 15ms e amplitu<strong>de</strong> superior<br />

a 2mv. Sera discutida a correiacao entre largura e amplitu<strong>de</strong> sinless pars limiar fixo.<br />

*Participaram: CBPF: Elly Silva , Nilton Alves, Margaretn Silva; IFUSP: E.W. Hamburger, O.<br />

Dietzsch; IAGUSP: E.J. Pacheco, J.A. Pacheco, L. Galhardo Jr.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!