Prevederi vizind cosuri de fum montate in interiorul cladirilor, tip jeremias dw400 / dw400 fu / dw600 /<br />

dw600 fu in urmatoarele tari:<br />

(FR) France (BE) Belgium<br />

(NL) Netherlands (CH) Swiss<br />

(AT) Austria (IT) Italy<br />

(NO) Norway (SE) Sweden<br />

(FI) Finnland (GR) Greece<br />

(LU) Luxembourg (GB) Great Britain<br />

(IE) Ireland (IS) Iceland<br />

(SK) Slovakia (ES) Spain<br />

(PT) Portugal (TR) Turkey<br />

(SLO) Slovenia (CZ) Czechia<br />

(HU) Hungria<br />

Daca sistemul de evacuare a gazelor de ardere se monteaza in interiorul unei cladiri, e necesara<br />

amplasarea acestuia in interiorul unei ghene in functie de constructie fig. 14b si 14c in functie de<br />

reglementarile nationale sau regionale.<br />

Materialul din care se construieste ghena, respectiv stratul exterior: Ei90 (L90/F90)<br />

Stratul exterior conform DIN V 18160-1, ex.:<br />

- fittinguri confectionate din beton DIN 18150-1*<br />

- fittinguri confectionate din beton DIN 18147-2 cu grosimea peretelui ≥ 5,0 cm<br />

- caramizi conform DIN 105-1 and DIN 105-3* cu exceptia caramizilor perforate vertical<br />

l C cu grosimea ≥ 11,5 cm<br />

- piatra moale conform DIN 106-1* cu grosimea ≥ 11,5 cm<br />

- caramida de zgura conform DIN 398 cu grosimea peretelui ≥ 11,5 cm<br />

- gas concrete – building block according to DIN 4165* cu grosimea peretelui ≥ 10,0 cm<br />

- beton usor conform cu DIN 18151* cu grosimea peretelui ≥ 17,5 cm<br />

- bloc beton plin conform DIN 18152* cu grosimea peretelui ≥ 11,5 cm<br />

( * ) sau din standarde mai recente