11.07.2015 Views

z. Echipamente medie tensiune, Post de ... - BRIO ELECTRIC

z. Echipamente medie tensiune, Post de ... - BRIO ELECTRIC

z. Echipamente medie tensiune, Post de ... - BRIO ELECTRIC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

www.brioelectric.roDMS - SLIMDISPOZITIV PENTRU MONTAREA SCURTCIRCUITOARELOREARTHING DEVICE DOUBLE FIXINGDestinat montǎrii dispozitivelor <strong>de</strong> legare la pǎmânt şi în scurtcircuit tip DPS-L3 (producţie EPG) pe liniile electriceaeriene cu conductoare izolate ( SLIM ).For mounting of grounding equipment type DPS-L3 (EPG ma<strong>de</strong>) on the overhead lines with covered conductors.Caracteristici tehnice / Technical Datasecţiune conductor izolatsection range of the covered conductorscurent maxim <strong>de</strong> scurtcircuit ( 1 secundǎ)maximum short-circuit current (1 sec.)Masaweightmomentul <strong>de</strong> strângere al şurubului <strong>de</strong> fixare a clemei pe conductortightening torqueUMMUValoareValuemm 2 35 – 120kA 11kg 0,75Nm 46NOTĂ:Gaura Φ 17 mm din armǎtura dispozitivului este <strong>de</strong>stinatǎ montǎrii unui corn <strong>de</strong> protecţie pentru a realiza şi un corn <strong>de</strong><strong>de</strong>scǎrcare superior ( CDC ).NOTE:The Φ 17 mm hole is <strong>de</strong>stined for mounting of an upper arc horn in or<strong>de</strong>r to realize an upper arc <strong>de</strong>vice (CDC).DPLI-SDISPOZITIV DE PROTECŢIE PE LANŢURI DE ÎNTINDEREPOWER ARC DEVICES FOR TENSION STRINGSSe monteazǎ pe capele terminale ale izolatoarelor siliconice tipITS70/II respectiv ITS 70/IV.For mounting on the end fittings of composite insulators typeITS 70/II anf ITS 70/IV.Caracteristici tehniceTechnical DataUMMUValoareValuecurent maxim <strong>de</strong> scurtcircuitmaximum short-circuit currentkA 10masaweightDPLI – S kg 0,85NOTĂ:Distanţa <strong>de</strong> <strong>de</strong>scǎrcare <strong>de</strong> 80 ÷ 150 mm între coarne este informativǎ. Proiectantul liniei va <strong>de</strong>fini distanţa realǎ înfuncţie <strong>de</strong> zona keraunicǎ.NOTE:The distance of 80 ÷ 150 mm between the arc <strong>de</strong>vices is informative. The line <strong>de</strong>signer should <strong>de</strong>fine it, <strong>de</strong>pending onthe keraunic area.EPG<strong>Echipamente</strong> pentru linii electrice aeriene şi instalaţii <strong>de</strong> <strong>medie</strong> <strong>tensiune</strong>38Equipments for medium voltage overhead lines and installationsoffice@brioelectric.ro

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!