13.07.2015 Views

RDI LongRanger 75Khz ADCP

RDI LongRanger 75Khz ADCP

RDI LongRanger 75Khz ADCP

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Workhorse Long Ranger75-kHz <strong>ADCP</strong>Technical SpecificationsTypical Performance (maximum power)Depth Range, High Std. Dev. 2 Range, Long Std. Dev. 2Cell Size 1 Res. Mode High Res. Mode Range Mode Long Range Mode4m 418m 12.9cm/s 528m 26.5cm/s8m 451m 6.1cm/s 563m 12.6cm/s16m 488m 3.0cm/s 604m 6.1cm/s32m 530m 2.0cm/s 648m 4.1cm/s1User’s choice of depth cell size is not limited to the typical values specified.2Single-ping standard deviation (Std. Dev.).Profile ParametersNot designed for use on moving vesselsVelocity accuracy: ±1% of the watervelocity ±0.5cm/s.Velocity resolution: 0.1cm/sVelocity range: ±5m/s (default±10m/s (maximum)Depth cell size: 4–32mNumber of depth cells: 1–128Ping rate: 1Hz (typical)Echo Intensity ProfileVertical resolution: depth cell sizeDynamic range: 80dBPrecision: ±1.5dB (relative measure)Transducer and HardwareBeam angle: 20°Configuration: 4-beamInternal memory: Two PCMCIA slots;one memory card includedCommunications: RS-232 or RS-422;ASCII or binary output at 1200–115,400baud.PowerDC input: 20–60VDC. Four internalalkaline battery packs.Voltage: 42V DC(new) 28VDC (depleted)Capacity (each pack): @ 0°C: 400 WatthoursTransmit at 35V:• 1000W (max power)• 80W (lower power, Long Range mode)• 20W (low power, BroadBand mode)Standard SensorsTemperatures (mounted on transducer):Range: -5° to 45°CPrecision: ±0.4°CResolution: 0.01°Tilt: Range: ±15°Accuracy: ±0.5°Precision: ±0.5°Resolution: 0.01°Compass (fluxgate type, includesbuilt-in field calibration feature):Accuracy: ±2°Precision: ±0.5°Resolution: 0.01°Maximum tilt:±15°EnvironmentalStandard depth rating: 1500mOperating temperature: -5° to 45°CStorage temperature: -30° to 75°CWeight in air: SC 86kg, DR 58kg,ExtBC 39kgWeight in water: SC 55kg, DR 36kg,ExtBC 16kgSoftwareUse <strong>RDI</strong>’s Windows TM -based software forthe best results:• WinSC—Data Acquisition• Win<strong>ADCP</strong>—Data Display and Export• <strong>RDI</strong>Tools—UtilitiesAvailable Options• 3000m pressure-rated configuration• External Battery Case (ExtBC)• Mooring accessories: In line andbottom mount accessories availablefrom Flotation Technologies andMooring Systems.• Remote head configurations• Memory: Up to 2 gigabytesDimensions922mm(ExtBC)550mm178mm1,014mm(SC)Self-Contained493mm(DR)Direct ReadingPressure Sensor:Accuracy: ±5mAcoustic Doppler Solutionswww.rdinstruments.comRD Instruments9855 Businesspark Avenue, San Diego, CA 92131 USATel. +1-858-693-1178 • Fax +1-858-695-1459 • E-mail: sales@rdinstruments.com<strong>RDI</strong> Europe, Les Nertières, 5 allée Hector Pintus, 06610 La Gaude, FranceTel. +33-49-211-0930 • Fax +33-49-211-0931 • E-mail: rdi@rdieurope.comSpecifications subject to change without notice. Rev. 0104

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!