03.05.2017 Views

House utian Ground Floor

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

220 2,780 28,376 220<br />

23<br />

22<br />

21<br />

20<br />

19<br />

18<br />

17<br />

16<br />

15<br />

14<br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

220 220 680<br />

soil pipe in<br />

cavity from staff<br />

3<br />

2<br />

1<br />

3<br />

2<br />

1<br />

3<br />

2<br />

1<br />

1,120 280 2,504<br />

3,624<br />

3,624<br />

high cupboards above<br />

work top<br />

904 1,000 600<br />

fire door to<br />

comply with NBR<br />

4,643<br />

1,000 2,540 1,000<br />

1,000 2,540 1,000<br />

shutter 4,540<br />

shutter<br />

fire door to<br />

comply with NBR<br />

2,560<br />

line of slab above<br />

work top<br />

line of slab over<br />

fire door to<br />

comply with NBR<br />

1,700<br />

520 1,000 880 3,490 1,000 50<br />

300<br />

line of slab above<br />

2,280<br />

300<br />

31,596<br />

1,780 3,000<br />

300<br />

31,621<br />

server<br />

2,520 1,180 220 6,754 948<br />

220 3,700<br />

220 754 753 753 1,220 220<br />

220<br />

377 377 376 377 377<br />

2,330<br />

377<br />

1,500 8,000<br />

4,173 3,253 573<br />

line of slab above<br />

new 2400h internal boundary wall<br />

3,260<br />

automated<br />

pool cover pit<br />

800<br />

600<br />

22<br />

7<br />

ottoman<br />

Ø100mm soil pipe laid to min 1:60 fall<br />

and to protected from any load above<br />

refer to drainage notes<br />

sliding door<br />

Ø100mm soil pipe laid to min 1:60 fall<br />

and to protected from any load above refer to drainage notes<br />

braai<br />

steel support columns as<br />

per engineer's detail<br />

steel support columns as<br />

per engineer's detail<br />

notes<br />

The design on this drawing remains the property of the architects copyright reserved. All dimensions<br />

to be checked on site before any work is put in hand.<br />

Do not scale off drawings! When in doubt, phone the architects!<br />

34,993<br />

220 3,093 25,400 6,060 220<br />

220 28,993 5,560 220<br />

220 9,653 19,340 5,560 220<br />

· <strong>Ground</strong> bearing tests to be carried out by engineer prior to construction.<br />

· All foundation footing sizes to be certified by engineer.<br />

· All structural concrete, brick and timber work to engineer's specification.<br />

· Final levels of buildings to be confirmed with architect.<br />

· All storm water sumps, discharge pipes, run-offs to engineer's specification.<br />

· All existing drainage to be checked by engineer and re-routed.<br />

· Provide expansion joints between all old and new work.<br />

· Provide 25mm polystyrene insulation under & up the side all surface beds in all rooms to receive<br />

underfloor heating.<br />

· All existing trees to be protected against any damage.<br />

· Allow for 1x water point to all private gardens.<br />

· All freestanding walls to comply with NBR part K, table 5.<br />

· All specified brand name materials to be in strict accordance with manufactures specifications &<br />

details.<br />

· All drainage and plumbing specifications in accordance with NBR<br />

· Top of all garden / external exposed & parapet walls to be waterproofed with sealant.<br />

FOUNDATIONS<br />

220 15,653 6,694 6,366 280 5,560 220<br />

A<br />

sec<br />

B<br />

sec<br />

C<br />

sec<br />

D<br />

sec<br />

a1<br />

a2<br />

FLOORS<br />

refer to structural engineers foundation drawings for size and depth of footings,<br />

piles, retaining walls , site excavation and compaction280 mm cavity walls<br />

(exterior), 300 cavity walls (exterior, where plumbing stacks are to beconcealed as<br />

indicated) 330mm foundation walls, 700 x 300 concrete footings.110mm walls 450<br />

x 250mm thickened surface bed<br />

provide 1000 mi tarcon vertical tanking to foundations walls at all level changes up<br />

to heights900mm. greater changes to receive derbigum waterproofing to manufacturers<br />

typical tv pt (3 + 4)<br />

long box<br />

drainage notes:<br />

EXISTING DRAINAGE:<br />

All existing sanitary fittings, supply pipes, waste pipes and soil pipes to be<br />

inspected.<br />

DRAINAGE SPECIFICATION:<br />

65mm deep reseal traps to all waste fittings. Waste pipes to be accessible along their<br />

entire lengths. R.e.'s at all branches and changes in direction. Asp's to drops<br />

exceeding 1200mm, at traps or invert levels. W.p.'s to the one pipe system to be fitted<br />

with vent valves. I.e.'s within 1200mm of upper extremeties of branch drains. 're's' at<br />

max. 24m intervals in straight runs of sewer. Encase drains less than 450mm from final<br />

ground level or under building in 400x400mm concrete to comply with P27 & P30 of<br />

NBR. All connections under building to be accessible via sealed inspection chambers.<br />

All pipe fittings etc. to be of first grade quality and installed in accordance with the<br />

National Building Regulations, local by-laws & to the approval of the architect. All work<br />

to be done by properly skilled & licensed plumbers and drainlayers.<br />

All soil, stack & vent a.s.v.p's to be Upvc and to comply with SABS 791 & 976 and laid<br />

according to SABS 0112 & 058 (class D beds). Soft or loose patches in drain trenches<br />

as well as excavations taken out too deeply to be filled with selected fine soil and<br />

rammed. Cleaning eye lids in drain pipes to be synthetic rubber packing, screwed or<br />

pressed into position.<br />

Inspection eye at bottom of vertical drain stacks.<br />

Min. fall to drain pipes to be 1:60<br />

PLUMBING SPECIFICATION:<br />

All plumbing work is to be executed by registered artisans.<br />

Test existing drainage systems for adequacy prior to new installations, where<br />

applicable.<br />

Where required, architects drawings to be read in conjunction with engineer's drawings.<br />

All water supply pipes above ground to be copper to SABS 460 & below ground to be<br />

Upvc to SABS 966. Underground water supply pipes to be at least 400mm below<br />

surface.<br />

All water piping to bathrooms, kitchens & scullery and directed elsewhere to be chased<br />

into walls and concealed. Soil & waste pipes to be concealed as far as possible.<br />

Provide and fix stopcocks to the main supply pipes, where directed, and to all sanitary<br />

fittings. All internal stopcocks to be chromium plated, external brass.<br />

220 2,780 11,003 1,810 15,562 220<br />

220 2,780 11,003 1,810 15,562 220<br />

E<br />

sec<br />

F<br />

sec<br />

G<br />

sec<br />

H<br />

sec<br />

1,446<br />

6,427<br />

2,877<br />

110 730 3,090 2,497<br />

209<br />

475 476<br />

D15 - shutter<br />

3,693<br />

Ch-05<br />

W02<br />

W01<br />

1,030 3,307<br />

pizza oven prep area to later detail<br />

waterproof<br />

floor plug<br />

810<br />

220 590<br />

line of slab above<br />

Ch-04<br />

covered deck<br />

deck<br />

2 1 uffl -0.650<br />

ie<br />

ie<br />

re<br />

ie<br />

F F<br />

lawn<br />

drying yard<br />

ie<br />

2<br />

6<br />

counter<br />

with prep<br />

rwdp<br />

soil pipe in cavity<br />

from main bathroom<br />

rwdp<br />

rwdp<br />

ie<br />

600<br />

tv<br />

rwdp<br />

1<br />

600<br />

4<br />

7<br />

2<br />

5,350<br />

600 1,200 220<br />

stairs up<br />

1,910 220 1,2002<br />

onto roof<br />

below<br />

D01<br />

Ch-03<br />

iD01<br />

cold<br />

room<br />

rwdp<br />

sliding door<br />

living room<br />

timber<br />

uffl -0.510<br />

4<br />

ceiling bulkhead above<br />

island<br />

1600 x 3000<br />

gas stove<br />

work top<br />

2<br />

high cupboards above<br />

16<br />

15<br />

double<br />

volume above<br />

kitchen<br />

screed<br />

uffl +0.000<br />

pop up by bluline<br />

line of slab over<br />

prep<br />

4<br />

17<br />

14<br />

service yard<br />

13<br />

18<br />

pantry<br />

D05<br />

12<br />

19<br />

11<br />

20<br />

2<br />

10<br />

iD01<br />

21<br />

9<br />

iD01<br />

rwdp<br />

2<br />

iD02<br />

2<br />

R 2,500<br />

R 860<br />

2<br />

8<br />

D07<br />

dbl sink<br />

garden<br />

D04<br />

2<br />

6<br />

Ch-01screed<br />

uffl +0.000<br />

DW<br />

td<br />

wm<br />

220 900 3,760<br />

4<br />

store room<br />

below stairs<br />

ie<br />

covered<br />

terrace<br />

artivia<br />

uffl -0.510<br />

5<br />

sliding door<br />

exist. jacaranda<br />

4<br />

dining room<br />

timber<br />

uffl -0.510<br />

3<br />

2<br />

sliding door<br />

Ch-01<br />

stairs up<br />

D10<br />

7,300<br />

wt<br />

2<br />

scullery / laundry<br />

4<br />

1<br />

W12<br />

low slot window<br />

rwdp<br />

dbl sink<br />

new 2400h internal boundary wall<br />

courtyard<br />

D08<br />

soil pipe in cavity<br />

from rwdp bathroom 2<br />

2<br />

stairs up<br />

iD03<br />

baby pool<br />

3260mmx<br />

2000mm<br />

portion 2 of 1867<br />

site 1100m²<br />

bic<br />

6,000<br />

2 air con spec tbc<br />

Ch-01<br />

swimming<br />

pool<br />

7830mmx3260mm<br />

iD05<br />

iD04<br />

W09<br />

iD04<br />

Ch-02<br />

1,500<br />

as per elegant<br />

system spec<br />

2<br />

W05<br />

10,684<br />

D02 280 11,926<br />

cavity slider<br />

entrance<br />

screed<br />

D01 - custom timber<br />

Ch-06<br />

uffl +0.000<br />

4,732 2,360 1,920 414<br />

1,500 1,455 1,455 1,956<br />

soil pipe in cavity<br />

from bathroom 4<br />

staff<br />

entrance<br />

re<br />

2<br />

project<br />

7screen as per<br />

to<br />

later detail elegant<br />

system spec<br />

iD01<br />

re<br />

W13<br />

W11<br />

soil pipe in<br />

cavity from<br />

bedroom<br />

ie<br />

W13<br />

W13<br />

ie<br />

rwdp<br />

220 3,091 280 2,400 220 3,380 280 6,000 280 6,000 269 11 5,400 1,100 280 5,560 220<br />

220 3,091 6,560 4,990 900 110 2,480 1,600 2,480 1,950 1,450 2,280 1,100 5,560 220<br />

220<br />

3,091 6,560 6,000 6,550 11 6,780 5,560 220<br />

220 3,091 25,400 6,060 220<br />

34,991<br />

whb<br />

3<br />

high level window<br />

ie<br />

artivia<br />

line of slab above<br />

sliding door<br />

formal lounge<br />

timber<br />

uffl -0.510<br />

flueless gas<br />

fireplace<br />

iD01<br />

cloak<br />

engineered timber<br />

uffl +0.000<br />

wc<br />

bike room<br />

rubber matting<br />

uffl +0.000<br />

2<br />

D03<br />

4 3 2<br />

server<br />

coats<br />

store<br />

3<br />

air con spec<br />

tbc<br />

line of slab above<br />

storage<br />

steps<br />

down<br />

4,516<br />

covered walkway<br />

artivia<br />

uffl +0.00<br />

2 x garage<br />

black slate tiles<br />

uffl -0.170<br />

mudroom<br />

3below counter<br />

41100h<br />

high level window<br />

W08<br />

D09<br />

W10<br />

garden<br />

gate<br />

Ø100mm soil pipe laid to min 1:60 fall<br />

and to protected from any load above refer to drainage notes<br />

2<br />

as per elegant<br />

system spec<br />

4<br />

W04<br />

7<br />

pp for pool<br />

cover/water feature<br />

rwdp<br />

4<br />

high level window<br />

steps<br />

down<br />

4<br />

coats<br />

columns to<br />

engineer's<br />

detail<br />

steps<br />

down<br />

lawn<br />

Ø100mm soil pipe laid to min 1:60 fall<br />

and to protected from any load above refer to drainage notes<br />

W07<br />

garden<br />

gate<br />

rwdp<br />

rwdp<br />

D10<br />

10,426<br />

garden gate<br />

rwdp<br />

pond by<br />

specialist<br />

5,560<br />

driveway<br />

courtyard<br />

granite cobble paver<br />

uffl -0.170<br />

existing 4.5m builing line<br />

proposed 3m builing line<br />

re<br />

ie<br />

ie<br />

ie<br />

220 5,034 6,000 470 220 19,457 220<br />

new manhole to tie into<br />

exiting sewer line<br />

E<br />

sec<br />

F<br />

sec<br />

G<br />

sec<br />

H<br />

sec<br />

site access<br />

220 2,780 280 280 944 280 6,940 280 2,000 6,280 11,117 220<br />

220 1,580 900 580 1,224 750 6,000 750 2,000 1,810 4,470 11,117 220<br />

220 2,780 1,504 7,500 19,397 220<br />

220 2,780 28,400 220<br />

b1<br />

b2<br />

b3<br />

b4<br />

b5<br />

b6<br />

b7<br />

b8<br />

b9<br />

WALLS<br />

c1<br />

c2<br />

c3<br />

c4<br />

c5<br />

c6<br />

c7<br />

c8<br />

c9<br />

CEILINGS<br />

d1<br />

d2<br />

d3<br />

d4<br />

d5<br />

d6<br />

d7<br />

ROOF<br />

e1<br />

e2<br />

DOORS & WINDOWS<br />

f1<br />

f2<br />

f3<br />

f4<br />

f5<br />

f6<br />

FIRE PLACES<br />

g1<br />

g2<br />

RevID ChID Description Date<br />

01 -<br />

WIP<br />

Ch-01<br />

Ch-02<br />

Ch-03<br />

Ch-04<br />

Ch-05<br />

Ch-06<br />

Door Move<br />

Pool Change<br />

Window Change<br />

Braai Change<br />

New fireplace<br />

New Door<br />

drawing status<br />

jvr<br />

architects<br />

and<br />

interiors<br />

project title<br />

Concrete reinforced surface bed (min 85mm) on 250micron Tarkon damp proof<br />

membrane, on min150mm good, clean hard core consolidated fill, treated with ant poison<br />

according to SABS 024. Hardcore fill to be compacted in layers to engineer's<br />

specification. Provide 40mm tongue & groove edge profile isoboard for insulation under<br />

concrete surface bed insulation to extend up at walls for the depth of the surface bed.<br />

Structural slabs, floors, supports, stairs and beams to engineer's specifications<br />

Selected porcelain tiles (interior) set in mortar bed, cement joints to approval.<br />

Selected carpet on underfelt by specialist<br />

Teak or approved hardwood duckboarding over grano on derbigum waterproofing in<br />

shower traysformed by 85mm step in concrete<br />

earthcoted pigmented floor coat by specialist<br />

Selected ceramic tiles (interior) set in mortar bed, cement joints to approval<br />

Selected cobble stone paving to approved pattern to fall on compacted hardcore fill.<br />

50mm widesurrounds to approval.<br />

300mm x 300mm slate tiles set in mortar bed, cement joints to approval, sealed to<br />

manufacturersspecifications.<br />

Flush jointed clay stock bricks with smooth plaster (outside walls), smooth plaster (inside<br />

walls), to receive approved Dulux paint finish to manufacturer's<br />

specification.<br />

External: Dulux Weatherguard paint colour to approval.<br />

Internal: Dulux Pearlglo paint colour to approval.<br />

Tarkon brickgrip dpc under all walls and sills, brickforce every 6 courses<br />

1020h balustrade to detail to comply with NBR.<br />

30x30mm shadowline in plaster for recessed skirting<br />

Selected natural stone wall by specialist to engineers detail and specification<br />

selected ceramic tiles<br />

Selected porcelain tiles.<br />

Selected timber cladding to architects specification and approval<br />

selected facebrick wall to architects specification and approval<br />

New flush plastered 8,5mm rhinoboard ceiling with taped joints, fixed to manufacturer's<br />

spec aluminium grid system fixed to underside of rc slab, paint finish as for walls. 200mm<br />

air gap for fibre insulation<br />

raked flush plastered 8,5mm rhinoboard ceiling with taped joints, fixed to<br />

38x38mm sap branderingboards fitted between rafters and/or trusses, paint finish as for<br />

walls.<br />

Internal to underside of r/c slabs: one coat cement plaster, one coat rhinolite, paint finish<br />

as for wallsExternal to underside of r/c slabs: one coat cement plaster, paint finish as for<br />

walls.<br />

Hardwood profiled cornice to detail, for painting.<br />

Neat and accurate joint between wall & ceiling, 20x20mm shadowline.<br />

Provide 2 x 50 mm ISOTHERM insulation to all ceilings.<br />

Off-shutter concrete underside slab, brushed and cleaned to architects detail and approval<br />

Waterproofing membrane to top of all parapet walls, free standing walls and beams with<br />

plastercoping to architects detail<br />

Reinforced concrete roof slab to eng's spec. with screed to fall to Ø160 fullbore outlets<br />

with 4mmDerbigum waterproofing to be taken up to the outer corners of the parapet walls<br />

by specilistcovered with 40mm ISOBOARD insulation, topped with 40mm thick layer of<br />

course Ø 6mm naturabrown gravel<br />

External: approved powder coated aluminium door & window frames.<br />

Internal: approved timber door & window frames.<br />

Provide safety crash bar in frame at opening sections at 1020h. To comply with SABS<br />

1263 Part 3 1988. Light and ventilation to comply with part O of NBR 0400.<br />

All glazing as per window schedule, to be min. 6,78mm laminated HPR glass with polyvinyl<br />

interlayer<br />

15 ° Sloped plastered silll, with built in dpc & drip to architect's detail.<br />

Skylights to detail by specialist.<br />

External: to architect's detail, installed to manufacturer's spec.<br />

Internal: to architect's detail, installed to manufacturers spec.<br />

project description<br />

s.a.c.a.p. reg, nr 6768<br />

Work in Progress<br />

construction<br />

jvr architects and interiors<br />

4 desmond street<br />

first floor, kramerville, south africa<br />

po box 72051, parkview<br />

2122 johannesburg south africa<br />

t +(27) 11 262 0905<br />

f +(27) 11 262 0189<br />

joe@jvrarchitects.co.za<br />

joevanrooyen.co.za<br />

house <strong>utian</strong><br />

Geyser connections by plumber. Geysers, overflow trays and valves to comply to<br />

SABS 0254. - Kwikot Megaflow.<br />

Allow No. garden tap points around house. all taps to be controlled from central<br />

irrigation station. Position of taps to be determined by landscaper.<br />

STORMWATER SPECIFICATION:<br />

380 x 380mm L/D cast iron grid inlets in 450 x 450mm concrete surrounds to 500 x<br />

500mm junction boxes. All stormwater pipes to be Ø 160mm Upvc, where stormwater<br />

is not surface drained. Encase drains less than 450mm from final ground level or<br />

under building in 400 x 400mm concrete<br />

Final layout to structural engineer's details and specification.<br />

LEGEND:<br />

b<br />

ss<br />

sws<br />

bid<br />

fr<br />

sp<br />

lb<br />

fz<br />

gt<br />

sh<br />

wm<br />

ie<br />

wc<br />

re<br />

dw<br />

mh<br />

s<br />

ovp<br />

wtr<br />

vp<br />

pb<br />

wp<br />

vv<br />

swp<br />

bath<br />

stub stack<br />

storm water sump<br />

bidet<br />

fridge<br />

soil pipe<br />

handwashbasin<br />

freezer<br />

gully trap<br />

shower<br />

washing machine<br />

inspection eye<br />

water closet<br />

rodding eye<br />

dish washer<br />

manhole<br />

sink<br />

overhead vent pipe<br />

wash trough<br />

vent pipe<br />

preparation bowl<br />

waste pipe<br />

vent valve<br />

storm water pipe<br />

new wall =<br />

new natural stone =<br />

roof above =<br />

off shutter r/c =<br />

concrete<br />

key to colours:<br />

vent pipes =<br />

waste water =<br />

soil pipes =<br />

existing =<br />

existing manhole<br />

A<br />

sec<br />

B<br />

sec<br />

existing sewer line<br />

C<br />

sec<br />

13th avenue<br />

D<br />

sec<br />

existing sewer line<br />

N<br />

ground floor plan<br />

scale 1:100<br />

new manhole to tie into<br />

exiting sewer line<br />

drawing information<br />

scale<br />

date<br />

drawn by<br />

revision number<br />

project number<br />

drawing number<br />

proposed new dwelling for<br />

K2011134166 (Pty) Ltd<br />

on portion 2 of erf 1867<br />

17, 13th avenue, houghton estate<br />

johannesburg<br />

ground floor plan<br />

1:100<br />

3/28/2017<br />

cp, ldv<br />

F<br />

J187B<br />

(04) 01

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!