22.06.2018 Views

Jenkins-Motor-Test-Systems-2018-Pricing-and-Specifications

  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ADD-ONS & MONITORING<br />

EQUIPMENT<br />

FEATURES<br />

DC<br />

SYSTEMS<br />

<strong>2018</strong> TEST & MONITORING SYSTEMS<br />

PRICING & SPECIFICATIONS<br />

AC<br />

MOTOR TEST<br />

Model<br />

Part #<br />

Base Price<br />

includes Aux. DC Armature Supply, TDS<br />

SYSTEM REQUIREMENTS<br />

Physical Space Required (inches)<br />

Electrical Input (60HZ)<br />

AC SUPPLY<br />

AC Nominal Full Load Starting Capacity*<br />

AC Nominal No Load Starting Capacity*<br />

AC Outputs**<br />

(25%-35% Full Load)<br />

AC Percentage Adjustment<br />

Note: Input tap to be connected at<br />

install only.<br />

Soft Starting<br />

Full Voltage Starting<br />

Current Limit Protection<br />

AUXILIARY AC SUPPLY<br />

Max Auxiliary AC Output**<br />

Current Limit Protection<br />

60V<br />

120V<br />

208V<br />

240V<br />

480V<br />

600V<br />

1200V<br />

2400V<br />

4200V<br />

7200V<br />

50%<br />

60%<br />

70%<br />

80%<br />

90%**<br />

100%**<br />

110%**<br />

115%<br />

100 KVA<br />

S100LV480ACDC-G2<br />

$54,000<br />

72 h x 36 w x 36 d<br />

480V 150A<br />

100 HP<br />

350 HP<br />

200A<br />

200A<br />

200A<br />

200A<br />

130A<br />

104A<br />

--<br />

--<br />

--<br />

--<br />

--<br />

--<br />

--<br />

--<br />

--<br />

N/A<br />

N/A<br />

166 KVA<br />

S166LV480ACDC-G2<br />

$69,200<br />

72 h x 36 w x 36 d<br />

480V 225A<br />

170 HP<br />

595 HP<br />

400A<br />

400A<br />

400A<br />

400A<br />

200A<br />

160A<br />

--<br />

--<br />

--<br />

--<br />

--<br />

--<br />

--<br />

--<br />

--<br />

N/A<br />

N/A<br />

200 KVA<br />

S200MV480ACDC-G2<br />

$109,800<br />

72 h x 72 w x 60 d<br />

480V 300A<br />

200 HP<br />

700 HP<br />

--<br />

400A<br />

--<br />

400A<br />

250A<br />

200A<br />

100A<br />

50A<br />

29A<br />

--<br />

333 KVA<br />

S333MV480ACDC-G2<br />

$135,500<br />

72 h x 96 w x 60 d<br />

480V 450A<br />

350 HP<br />

1225 HP<br />

--<br />

600A<br />

--<br />

600A<br />

400A<br />

320A<br />

160A<br />

80A<br />

45A<br />

26A-Optional<br />

500 KVA<br />

S500MV480ACDC-G2<br />

$196,400<br />

72 h x 96 w x 60 d<br />

480V 650A<br />

500 HP<br />

1750 HP<br />

--<br />

800A<br />

--<br />

800A<br />

600A<br />

480A<br />

240A<br />

120A<br />

69A<br />

40A-Optional<br />

750 KVA<br />

S750MV480ACDC-G2<br />

$272,200<br />

78 h x 108 w x 60 d<br />

480V 950A<br />

750 HP<br />

2625 HP<br />

--<br />

1000A<br />

--<br />

1000A<br />

900A<br />

720A<br />

360A<br />

180A<br />

103A<br />

60A-Optional<br />

1000 KVA-G2<br />

S1000MV480ACDC<br />

$316,000<br />

78 h x 120 w x 72 d<br />

480V 1250A<br />

1000 HP<br />

3500 HP<br />

--<br />

1000A<br />

--<br />

1000A<br />

1000A<br />

1000A<br />

500A<br />

240A<br />

142A<br />

83A-Optional<br />

1500 KVA<br />

S1500MV4200ACDC<br />

$389,800<br />

TBD<br />

4200V 210A<br />

1500 HP<br />

5250 HP<br />

--<br />

1000A<br />

--<br />

1000A<br />

1000A<br />

1000A<br />

735A<br />

367A<br />

210A<br />

122A-Optional<br />

2000 KVA<br />

S2000MV4200ACDC<br />

$423,600<br />

TBD<br />

4200V 275A<br />

2000 HP<br />

7000 HP<br />

--<br />

1000A<br />

--<br />

1000A<br />

1000A<br />

1000A<br />

962A<br />

481A<br />

275A<br />

160A-Optional<br />

0-560 28A 0-560 28A 0-560 28A 0-560 28A 0-560V 35A 0-560V 35A (UPGRADE CURRENT RATING)<br />

2500 KVA<br />

S2500MV4200ACDC<br />

$491,800<br />

TBD<br />

4200V 204A<br />

2500 HP<br />

8750 HP<br />

--<br />

1000A<br />

--<br />

1000A<br />

1000A<br />

1000A<br />

1000A<br />

612A<br />

350A<br />

204A-Optional<br />

DC FIELD SUPPLY<br />

DC Field Variable Output<br />

0-500V 10A 0-500V 10A 0-500V 28A 0-500V 28A 0-500V 28A<br />

0-500V 28A<br />

0-500V 35A<br />

0-500V 35A 0-500V 35A 0-500V 35A<br />

Field Loss Protection<br />

Temporary Bypass<br />

Current Limit Protection<br />

DC ARMATURE SUPPLY<br />

Max Armature Output**<br />

DC Armature Voltage Taps<br />

Current Limit Protection<br />

0-280V<br />

0-585V<br />

0-40V<br />

0-80V<br />

0-160V<br />

0-320V<br />

0-585V<br />

0-585V 75A<br />

75A<br />

75A<br />

--<br />

--<br />

--<br />

--<br />

--<br />

0-585V 100A<br />

--<br />

--<br />

100A<br />

100A<br />

100A<br />

100A<br />

100A<br />

0-585V 275A<br />

--<br />

--<br />

300A<br />

300A<br />

300A<br />

300A<br />

275A<br />

0-585V 300A<br />

--<br />

--<br />

300A<br />

300A<br />

300A<br />

300A<br />

300A<br />

0-585V 300A<br />

--<br />

--<br />

300A<br />

300A<br />

300A<br />

300A<br />

300A<br />

0-585V 300A<br />

--<br />

--<br />

300A<br />

300A<br />

300A<br />

300A<br />

300A<br />

0-585V 450A<br />

--<br />

--<br />

450A<br />

450A<br />

450A<br />

450A<br />

450A<br />

0-585V 450A<br />

--<br />

--<br />

450A<br />

450A<br />

450A<br />

450A<br />

450A<br />

0-585V 450A<br />

--<br />

--<br />

450A<br />

450A<br />

450A<br />

450A<br />

450A<br />

0-585V 450A<br />

--<br />

--<br />

450A<br />

450A<br />

450A<br />

450A<br />

450A<br />

AUXILIARY DC ARMATURE SUPPLY (480V input)<br />

Armature Output**<br />

Field Loss Protection<br />

0-500V 10A 0-500V 10A 0-500V 28A 0-500V 28A<br />

0-500V 28A<br />

0-500V 28A<br />

0-500V 35A 0-500V 35A 0-500V 35A 0-500V 35A<br />

FEATURES<br />

17” HMI Touch Screen Display<br />

<strong>Test</strong> Documentation Display<br />

Remote Diagnostics for TDS, PLC, Metering <strong>and</strong> Soft Starter<br />

UPS Included on Soft Starter Control Circuit <strong>and</strong> PLC Output<br />

Auxiliary 120V Control Circuit Outlet Rated 15 A<br />

<strong>Test</strong> Lead Isolation Box<br />

Graphic Overlay Legend Plates<br />

Temperature <strong>and</strong> Vibration Sensor Module<br />

Optional<br />

TDS SYSTEM FOR EXISTING EQUIPMENT<br />

Part #<br />

Base Price<br />

TDS Add-On Software,<br />

PC & Operator Console<br />

TDS-SW<br />

$3,795<br />

3 phase; 30 - 600 VAC<br />

TDS-ACLV<br />

$2,895<br />

3 phase; 210-4200 VAC<br />

TDS-ACMV<br />

$3,995<br />

3 phase; 360-7200 VAC<br />

TDS-ACHV<br />

$7,995<br />

3 phase; 0-500 VDC<br />

TDS-DC<br />

$5,295<br />

BOOM MOUNTED TEST LEAD<br />

Base Price (each)<br />

$3,250<br />

TEMPERATURE & VIBRATION MODULE<br />

Base Price<br />

$10,500<br />

OVEN TEMPERATURE DIGITAL RECORDER<br />

Recorder Price<br />

Armor-Clad Thermocouple Probe Type K (15 feet)<br />

Sold Separately<br />

VIBRATION ANALYZER<br />

Base Price<br />

4 Channel<br />

$2,900<br />

$16,125<br />

8 Channel<br />

$3,900<br />

$150/each<br />

16 Channel<br />

$4,900<br />

Have a question? Just CALL <strong>Jenkins</strong>.<br />

P (800) 438-3003 | F (800)-392-2612<br />

<strong>Jenkins</strong>Electric.com<br />

*Load starting capacity values are estimates, individual motors will vary in starting currents. For an evaluation specific to your application, please contact us at answers@jenkins.com.<br />

**Higher voltage taps available if needed.<br />

©<strong>2018</strong> <strong>Jenkins</strong>, All rights reserved.