03.07.2018 Views

Alangos bungalow final pdf

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

E-04<br />

12.150<br />

0.600<br />

0.150<br />

0.150<br />

0.600<br />

1.500 0.150<br />

0.150 3.000 0.150 3.000 0.150<br />

0.150 2.400<br />

1.350<br />

2.100<br />

1.000<br />

4.500<br />

3.000<br />

S-01<br />

S-01<br />

0.900<br />

1.200<br />

2.100<br />

0.150<br />

0.600<br />

0.150<br />

0.150<br />

1.500 0.150<br />

1.650<br />

0.150 3.750 0.150 1.200<br />

0.150 2.400<br />

12.150<br />

E-02<br />

8.150<br />

3.180<br />

0.750<br />

3.300<br />

1.650<br />

6.700<br />

2.619<br />

3.300<br />

4.003<br />

1.650<br />

0.150<br />

0.150<br />

2.400<br />

0.200<br />

8.900<br />

3.400<br />

0.200 1.000<br />

0.200<br />

0.600<br />

0.200<br />

1.000 0.200<br />

Z1<br />

Z1<br />

0.200 1.000<br />

0.200<br />

0.600<br />

0.200<br />

1.000 0.200<br />

3.400<br />

RIGHT HAND ELEVATION (002) LEFT HAND ELEVATION (004)<br />

REAR ELEVATION (003)<br />

Eaves overhang line<br />

3.514<br />

Eaves overhang line<br />

3.150<br />

3.150<br />

3.514<br />

Hip line<br />

fall<br />

fall<br />

Ridge line<br />

fall<br />

4.808<br />

3.150<br />

Eaves overhang line<br />

fall<br />

5.763<br />

6.293<br />

Valley line<br />

1.953<br />

3.323<br />

Eaves overhang line<br />

4.700<br />

Ridge line<br />

4.740<br />

Ridge line<br />

Valley line<br />

fall<br />

Ridge line<br />

Valley line<br />

Valley line<br />

Hip line<br />

Eaves overhang line<br />

1.939<br />

2.700<br />

Ridge line<br />

4.808<br />

Ridge line<br />

1.953<br />

3.323<br />

Valley line<br />

fall<br />

fall<br />

Ridge line<br />

3.463<br />

Hip line<br />

fall<br />

3.463<br />

3.750<br />

Eaves overhang line<br />

fall<br />

Eaves overhang line<br />

SCHEDULE FOR DOORS AND WINDOWS<br />

DOOR SCHEDULE<br />

MKNO. WIDTH HEIGHT QTY REMARKS<br />

D1 1200 2100 2 DOUBLE STEEL CORE DOOR.<br />

D2 900 2100 2 SINGLE STEEL CORE DOOR.<br />

D3 900 2100 3 STD BATTENED DOOR.<br />

D4 750 2100 2 STD FLUSH DOOR.<br />

WINDOWS SCHEDULE<br />

WI 1800 1200 2 STEEL CASEMENT WINDOW.<br />

W2 1500 1200 4 STEEL CASEMENT WINDOW.<br />

W3 900 1200 2 STEEL CASEMENT WINDOW.<br />

W4 600 600 2 STEEL CASEMENT WINDOW.<br />

GW1 2600 1500 1 GRILL WINDOW<br />

GW2 2100 1500 2 GRILL WINDOW<br />

GW3 1200 1500 1 GRILL WINDOW<br />

Section<br />

Ring beam specifications<br />

3mm diameter lateral<br />

ties @ 192 mm c/c<br />

4-12mm diameter bars<br />

GENERAL NOTES<br />

1.All dimensions are in mm unless otherwise specified.<br />

2.Drawings are not to be scaled,only figured dimensions to<br />

be used.<br />

3.All dimensions must be checked before construction<br />

comences<br />

CONSTRUCTION<br />

4.All slab at ground level to be poured over 1000 gauge<br />

polythene sheet on 50mm murram blinding on hardcore.<br />

5.All soil at ground around and under foundation to be treated<br />

with Aldrex or Rentokil to stop termite attacks.<br />

CIVIL<br />

6.All soil on cut embarkment to be stabalised.The slope not to<br />

exceed the natural angle of response.<br />

STRUCTURAL<br />

7.All black cotton soil to be removed from all building and paved<br />

surfaces.<br />

8.For all R.C work refer to structural Engineers details.<br />

9.Foundation depth to be determined on the site to S.Es approval.<br />

10.All walls less than 150mm thick to be reinforced with hoop iron<br />

at every alternate course.<br />

11.All adjascent R.C work and masornary wall to be tied with strip<br />

iron at every alternate course.<br />

MECHANICAL<br />

12.All plumbing and drainage to comply with relevant to local<br />

authority.<br />

13.SVP denotes soil vent pipes to be provided at the end of drainage<br />

system.<br />

14.Drainage pass beneth buildings and driveways to be encased in<br />

150mm concrete surroundining.<br />

15.The storm drain pipes to comply with BS 56 specifications .<br />

16.All underground foul and waste drain pipes shall be PVC to comply<br />

with BS 5255.<br />

17.All inspection chambers covers and framing be made of cast iron.<br />

18.Minimum slope in drain pipes to be 1 in 100.<br />

19.All testing of pipes must be completed before plastering.<br />

20.All mechanical works must be coordinated with electrical and any<br />

conflict must be clarified before the work begings.<br />

21.PV denotes permanent ventillation and must be provided on top of all<br />

openings except the washrooms.<br />

ELECTRICAL<br />

22.All conduits must be laid before plastering.<br />

FIRE<br />

23.Provide quantity 1.9KG powder portable fire extinguisher in the house.<br />

24.All fire positions to be determined on the site.<br />

6.800<br />

Eaves overhang line<br />

3mm diameter lateral ties<br />

@ 192mm c/c<br />

Revision notes<br />

S/no. Date Notes<br />

ROOF PLAN<br />

Scale : 1:100<br />

FRONT ELEVATION (001)<br />

Plan<br />

All scale 1:100<br />

12.000<br />

0.150 3.000 0.150 3.000 0.150 2.700 0.150 2.550 0.150<br />

W2 pv<br />

1.950<br />

1.950<br />

E-03<br />

2.100<br />

GW pv<br />

GW3<br />

pv<br />

Porch<br />

pv<br />

D2<br />

W1 pv<br />

W3 pv W3<br />

D2 pv<br />

Kitchen<br />

Dinning room<br />

Bedroom 2<br />

D3 pv<br />

2.600<br />

D4 pv<br />

D3<br />

pv<br />

D3 pv<br />

Store<br />

2.550<br />

W/C<br />

Bedroom 1 Sitting room Master Bedroom<br />

D4<br />

pv<br />

pv<br />

W/C<br />

W4W/C<br />

W2<br />

pv<br />

TO SEPTICK TANK<br />

1.594<br />

2.619<br />

2.425<br />

1.212<br />

ROOF NOTES<br />

-Ridge cover.<br />

-GCI sheets.<br />

-Pitch 25 degrees.<br />

-75 x 50 Purlins.<br />

-100 x 50 Kingpost.<br />

-100 x 50 Struts.<br />

-100 x 50 Tie beam.<br />

-100 x 50 Wall plate.<br />

-Ceiling brandering 600 c/c on.<br />

-Joilsts.<br />

-200 x 25 Fascia board.<br />

6.700<br />

0.800<br />

0.150<br />

Y1<br />

SEPTIC TANK DETAILS AND SPECIFICATION<br />

0.200<br />

0.200<br />

0.200<br />

0.600<br />

0.200<br />

0.600<br />

1.500<br />

A<br />

1.500<br />

FLOOR PLAN<br />

E<br />

0.200<br />

0.200<br />

7.500<br />

2.100<br />

E<br />

B<br />

2.100<br />

7.500<br />

0.200<br />

0.200<br />

1.500<br />

C<br />

1.500<br />

0.600<br />

0.200<br />

0.600<br />

0.200<br />

0.200<br />

0.200<br />

Y1<br />

INVERT<br />

LEVEL OF<br />

INCOMING<br />

DRAIN<br />

200MM MASONRY<br />

WALL WITH 10MM<br />

RENDERING BOTH SIDES<br />

IN LET<br />

600<br />

M.H.<br />

120MM COVER SLAB 100X250 M.H. COVER FRAME<br />

SECTION Y-Y<br />

10MM WATER 100<br />

FROOFED<br />

RANDERING<br />

12 MM dia ms<br />

bars at 150mm c/c<br />

bothways<br />

OUT LET<br />

M.H.<br />

TO SUB SOIL<br />

IRRIGATION<br />

W2<br />

pv<br />

pv<br />

D1 pv<br />

pv W1<br />

GW2<br />

GW2<br />

Verandah<br />

pv<br />

pv<br />

GW1 pv<br />

D1 pv<br />

2.600<br />

0.150 3.000 0.150 4.800 0.150 3.600 0.150<br />

12.000<br />

E-01<br />

FLOOR LAYOUT PLAN<br />

W2<br />

FOUNDATION STRIP SPECIFICATION NOTES<br />

-D.P.C sheets on.<br />

-25 mm floor screed on.<br />

-100 mm concrete slab on.<br />

-B.R.C mesh on.<br />

-D.P.M on.<br />

-50 mm murram blinding.<br />

-300 mm concrete hard core filling.<br />

SECTION X-X<br />

0.600<br />

SECTION Z-Z<br />

SEPTIC TANK DETAILS<br />

1.Cover slab to be reinforced with 0 10mm bars at 100mm c/c<br />

(conc.20/20 mix 1:2:4)class 18.<br />

2.Base slab to be concrete class @ mix1:3:6 class 20<br />

3.Outlet & inlet pipes to be 0 100 cast iron.<br />

4.Scum buffle to be 100mm thick reinforced with 2 NO 100MM<br />

at both ends on 20/20<br />

5.Divinding wall to be 100mm thick conc class 20/20 reinforced<br />

with weld mesh BR 165.<br />

SOAK PIT SECTION<br />

All scale 1:100<br />

project:<br />

PROPOSED RESIDENTIAL DEVELOPMENT TO BE BUILD AT<br />

-OSINGO VILLAGE.<br />

-SUNA EAST SUB-COUNTY.<br />

-MIGORI COUNTY.<br />

Client: MR. MOSE ALANGO<br />

P .O. BOX 14457-00800 NAIROBI.<br />

Drg type:<br />

ARCHITECTURAL<br />

Designed, Drawn & traced by: Clients signature:<br />

G .ARINGO .................................................<br />

Checked by:<br />

MR OMAR HAMISI MWAZIGHE<br />

Scale: 1: 100 Date: April 2017 Drg No. 05/17<br />

GSEducationalVersion

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!