08.12.2012 Views

Catalogue (PDF) - KAPO BOARD

Catalogue (PDF) - KAPO BOARD

Catalogue (PDF) - KAPO BOARD

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

www.kapoboard.com<br />

<strong>KAPO</strong> Board<br />

For Interior Wet or Dry Lining and Exterior Wall Use<br />

NON-COMBUSTIBLE<br />

MOISTURE RESISTANT<br />

100% ASBESTOS FREE<br />

INSULATION


I<br />

CONTENTS:<br />

Introduction 1<br />

<strong>KAPO</strong> products are tested with re-own standards 2<br />

Product dimension 3<br />

The model of safe environmental position 4<br />

Fixing and jointing 5<br />

Jointing internal wall 6<br />

Jointing treatment (seaming) 7<br />

Jointing partition 8<br />

Typical layout of sheet metal framework 9<br />

Installation flooring 10<br />

Installation R. C. Concrete ceiling 11<br />

Installation “T” section 12<br />

Installation frame reinforcement 13<br />

Installation dry wall 14<br />

www.kapoboard.com II


INTRODUCTION<br />

Enviro Square Ltd’s <strong>KAPO</strong> mineral board sheet is manufactured from non- toxic minerals incorporating a woven mesh that provides excellent fire,<br />

sound, moisture and mould resistant properties. Used extensively overseas as an alternative to fibre-cement and plaster based boards, <strong>KAPO</strong> Board<br />

is an ideal choice for interior lining solutions. The board is supplied in a number of thicknesses including 6mm, 9mm and 12 mm, allowing it to be<br />

employed for a number of uses such as; interior wall lining, partition walls and exterior soffits. Due to the nature of the manufacturing process and<br />

the product itself, one side of the board is smooth while the other is slightly rough enabling easy installation and correct placement. This smooth<br />

finish, with its low moisture absorption value allows <strong>KAPO</strong> Board to be easily and accurately tiled over in wet areas, such as bathrooms and kitchens.<br />

<strong>KAPO</strong> Board is deemed a Light Wall Cladding material based on NZS3604, being approximately 10kg/m2 (~30kg for a 2.4m x 1.2 sheet 10mm thick).<br />

Board sizes are typically supplied as 2.4m x 1.2m in size, covering the complete range of 6, 9 and 12mm thicknesses. Also with a density of 1.03,<br />

<strong>KAPO</strong> Board is also easy to cut to size using saws and drills enabling quick installation. Fixing is by way of galvanized clouts or Fibre Tek screws onto<br />

timber or lightweight steel framing, with joints then either flush filled or taped prior to application of the finishing surface. For interior use the board<br />

joints are usually filled with an Enviro Square approved jointing product to suit the beveled edges.<br />

www.kapoboard.com 1


<strong>KAPO</strong> PRODUCTS ARE TESTED WITH<br />

RE-OWN STANDARDS<br />

Fire Resistance<br />

ASTM E 136-99 - Standard Test Metaphor Behaviour of materials in a Vertical Tube Furnaces at 750<br />

Degree C.<br />

ASTM E119, CAN/ULC S101-M89, NFPA 251, UBC 7-1 (1997), and UL 263 - Fire Tests of Building<br />

Construction and Materials.<br />

GB/T 5464 -1999 (IDT ISO 1182) - Non-Combustibility Test Method of Building.<br />

GB8624-1997 - Burning behavior Classification Criteria for Burning Materials, rated as CLASS A<br />

Sound Insulation<br />

ASTM E90-2004 - Standard Test Method for Laboratory Measurement of Airborne Sound Transmission<br />

Loss of Building Partition.<br />

ASTM E413-04 - Classification for Rating Sound Insulation. 12mm - 49db, 16mm - 50db or Greater.<br />

Mold Resistance<br />

ASTM D3273 (2000) - Standard Test Method for the Resistance of Growth of Mold on the Surface<br />

of Interior Coating in an Environment Chamber, Section 7.1 through 7.3.<br />

Formaldehyde Emission<br />

GB18580-2001<br />

Class E1, limit of formaldehyde emission:


PRODUCT DIMENSIONS<br />

PRODUCTS LENGTH (mm) WIDTH (mm) THICKNESS (mm)<br />

Partition wall & Ceiling 2400 1200 4 - 18<br />

Suspended ceiling 610 610 6 - 9<br />

1220 610 6 - 9<br />

Roof Eave facial board 2440 250 12 - 18<br />

2440 250 12 - 18<br />

Tolerance +- 0.5 +- 0.5 +- 0.5<br />

PRODUCT FEATURES<br />

30 Years<br />

Fire rated, non Combustibility<br />

The advantages of <strong>KAPO</strong> <strong>BOARD</strong> are light, fireproof and waterproof.<br />

Superior Moisture and Mold Resistance<br />

<strong>KAPO</strong> will not rot, physically deteriorate, highly resistant to the effects of moisture. It absorbs moist and<br />

regains its full strength upon drying without changes to the long term performance of the board.<br />

Chemically stable<br />

Board are produced from natural, inorganic raw materials and chemical reaction is irreversible which<br />

results in a chemically stable board that is hard but flexible, a strong board that maintains its strength<br />

over time.<br />

Can be sawed and drilled<br />

Good thermal properties<br />

<strong>KAPO</strong> <strong>BOARD</strong> has less ability to transmit heat and is efficient thermal insulation.<br />

Safe to work with, containing no hazardous materials and 100% Asbestos free<br />

Resistant to climatic conditions and moisture<br />

Tested to many cycles of soaking, freezing, heating (freeze/thaw test method). The boards to showed<br />

no cracking, crumbling nor disintegration for applications within normal specifications, the life span of<br />

the board is limited only by the durability of the supporting structures and the materials used in fixing.<br />

Easy to work and fix<br />

<strong>KAPO</strong> <strong>BOARD</strong> has excellent workability that can be cut, drilled, sanded and worked with proper tools<br />

and machinery.<br />

Can be nailed<br />

Can be tiled and easily decorated<br />

Highly resistant and termite attack free<br />

Unlike plywood or wood based boards that harbors insect, mildews, molds, fungus and<br />

bacteria. <strong>KAPO</strong> <strong>BOARD</strong> maintains the beauty, cleanliness and healthy surroundings in your<br />

particular application.<br />

30 Years<br />

Must adhere to manufacturer recommended maintenance programme.<br />

www.kapoboard.com 3


STORAGE AND HANDLING<br />

Storage and handling<br />

The <strong>KAPO</strong> Board is supplied shrinkwrapped stacked on pallets and can be stored indefinitely when kept dry and out of the weather<br />

and safe from accidental damage.- External moisture<br />

Safe handling<br />

Individual boards should be stacked and handled carefully to avoid damage. RMS boards should be lifted from the pallet by sliding<br />

board sideways and carrying on long edges.<br />

Storage and transport<br />

Keep dry and store in dry and covered area, if product becomes wet allow to dry before fixing is recommended. <strong>KAPO</strong> is supplied<br />

on wooden pallets with support timbers at maximum 400mm centres. Ensure product is stored on EVEN ground.<br />

THE MODEL OF SAFE<br />

ENVIRONMENTAL PROTECTION<br />

Forced refractory ventilation<br />

duct for staircase<br />

<strong>KAPO</strong> Board<br />

Fireproof enclosure of<br />

ventilation duct<br />

<strong>KAPO</strong> Board<br />

Fireproof suspended<br />

ceiling<br />

<strong>KAPO</strong> Board<br />

Fire wall<br />

<strong>KAPO</strong> Board<br />

<strong>KAPO</strong> <strong>BOARD</strong> can be use in hospital, Hotel, Condominium or Warehouse<br />

Cable fireproof enclosure<br />

<strong>KAPO</strong> Board<br />

Fire protection of<br />

concrete unit<br />

<strong>KAPO</strong> Board<br />

Fireproof enclosure of<br />

steel column<br />

<strong>KAPO</strong> Board<br />

Fire protection of<br />

smoke extraction Duct<br />

<strong>KAPO</strong> Board<br />

<strong>KAPO</strong> <strong>BOARD</strong> can be apply as Basement carpark air Ducting, Ceiling, Roof insulator and Roof Eave facial board<br />

www.kapoboard.com<br />

4


FIXING AND JOINTING<br />

(BASIC INSTALLATION DETAIL)<br />

Screw mounting<br />

Fixing to timber framing shall be by way off 40mm long galvanised clouts with a Local Coating Thickness<br />

of 45 microns of zinc, at 200mm centres. Fixing to steel framing shall be by way of 20mm Fibre Tek screws.<br />

It is essential that the fixings are not closer than 12mm from the edge of the sheets and not over tightened.<br />

Nailing<br />

Both manual or power tool methods of fixing the nail into the sheet are acceptable using a flat head<br />

stainless steel nail. The diameter should be 2.2mm or 3.1mm with a length of 3 to 3.5 times the panel<br />

thickness. Set the power tools to 3 to 4 BAR and fine tuned to achieve required penetration. It is essential to<br />

align the sheet edge onto the center of the timber or steel structure. <strong>KAPO</strong> Boards should be installed on<br />

studs at a maximum of 600 mm.<br />

Cutting<br />

Cutting can be done either longitudinally or traverse. A cut should be made on the top side of the board<br />

by means of a cutter or knife. The boards should then be pressed with both hands, cut and then snapped<br />

over a straight edge. For smooth, clean cuts use a circular saw (at least 120 carbide teeth) and set the<br />

speed above 3000 rpm.<br />

Sawing<br />

Can be easily cut using a normal saw, fret saw or an electric saw. When large quantities of the boards are<br />

to be cut, the use of circular hand saw is advisable. Appropriate safety equipment should be worn.<br />

Drilling<br />

Use masonry drills to countersink or drill screws. Place the boards on a solid support for a clean hole.<br />

Sheet Joints<br />

<strong>KAPO</strong> Boards are suitable for mounting to both timber and metal framing. Studs are recommended at a<br />

minimum of 400mm centres. A sufficient gap between the joint 2 boards is required, nominally 4 mm.<br />

Support Structures<br />

<strong>KAPO</strong> Board sheets shall be supported by framing members spaced at no more than 600mm centres for<br />

both 6mm and 9mm thickness.<br />

PRODUCT APPLICATION<br />

Jigsaw Circular lar larr saw saw<br />

Electric ti c / /C / Compress ddrill drill il<br />

It also can be Paint, plastered, tilled, wall or wallpaper and floor slab for tilling<br />

www.kapoboard.com<br />

5


JOINTING INTERNAL WALL<br />

LAYOUT OF STEEL FRAME<br />

4mm GAP between boards<br />

Self-tapping screws (fasten at least<br />

10-15mm from the edge of board)<br />

JOINTING TREATMENT (SEAMING)<br />

LAYOUT OF TIMBER FRAME<br />

A. Fill with elastic joint or cornice compound<br />

into the gap<br />

B. Paper joint tape or fiber mesh<br />

C. Cornice compound finishing at 200mm<br />

Screw<br />

Timber frame<br />

3.5mm gap<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

Embedding (first) filling coat<br />

Joint tape (fiberglass mesh tape, others.) At 50mm<br />

Embedding (second) Coat at 200 mm<br />

Finishing (third) coat at 200 mm<br />

Glass wool<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

www.kapoboard.com 6


HOW TO INSTALL THE PRODUCT<br />

Fixing to timber framing shall be by way of 40mm long galvanised clouts with a Local Coating Thickness of 45 microns of zinc, at 200mm centres.<br />

Fixing to steel framing shall be by way of 20mm Fibre Tek screws. It is essential that the fixings are not closer than 12mm from the edge of the<br />

sheets and not over-tightened. All details of the construction and installation of the <strong>KAPO</strong> Board as an interior or exterior lining, must comply with<br />

NZS3604 except where varied by this Appraisal. Joints between boards are to be filled using Enviro Square approved jointing product, which may<br />

be applied by machine or by hand tool to a smooth finish Where an external render system is to be applied, the joints may be sealed in both the<br />

vertical and horizontal directions by way of ACIS Butyl Tape. There is a Technical Manual describing the correct method of installation of this tape<br />

FRAMING:<br />

<strong>KAPO</strong> Board must be used in conjunction with timber framing and other components of a wall assembly that comply with NZS3604 or in place<br />

of timber framing, with lightweight steel framing that complies with NASH 3405, in all respects except as varied herein, in order to meet the<br />

Performances of the Building Code claimed in this Appraisal.<br />

www.kapoboard.com 7


INSTALLATION PARTITION<br />

LAYOUT OF PARTITION WALL<br />

75mm steel stud at 400mm<br />

(insert studs to track with open<br />

sides facing in same direction<br />

and twist to secure).<br />

Horizontal stabilizer<br />

(Optional depends on length<br />

of wall).<br />

Timber frame<br />

50k glass fibre or rock wool<br />

insulation<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

Floor track fix to<br />

re-concrete<br />

Floor track<br />

JOINTING EXTERNAL WALL<br />

4mm GAP between boards 4mm GAP between boards<br />

ACIS Butyl Tape Fill with cement grout<br />

Exterior Finishes<br />

400/600mm 400/600mm 400/600mm<br />

200mm<br />

Self-tapping screws<br />

(Screws must not face across each<br />

other) distance between each<br />

screws = 200mm<br />

<strong>KAPO</strong> Board has been appraised as a Light Wall Cladding as defined in NZS3604 relying on 400mm or 600mm stud centres or soffit joist centres for<br />

Framing and using either 9 or 12mm thick board. This appraisal is limited to the boards and nominated jointing systems only and excludes any<br />

finishing system, which must comply with the relevant clauses of the New Zealand Building Code. The <strong>KAPO</strong> Board is to be installed by trade<br />

qualified builders.<br />

www.kapoboard.com 8


TYPICAL LAYOUT OF SHEET<br />

METAL FRAMEWORK<br />

PARTITION LAYOUT<br />

Cartridge firing pin: L.=25.4mm at 600mm<br />

Ceiling track: 67 x 40 x 0.8mm (min.)<br />

(CROSS SECTION HORIZONTAL VIEW)<br />

Silicone filter<br />

Secure track to ceiling & floor<br />

ensuring vertical alignment<br />

cartridge firing pin: L.=25.4mm,<br />

at 600mm<br />

Interior Finishes<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

Silicone filter<br />

Self-Tapping Screws at 250mm<br />

Nominal centre<br />

In filled insulation<br />

(Glass fiber, min.. 50mm or rock wool)<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

In-filled insulation (Glass fiber min..<br />

50mm or Rock wood<br />

C stud: 65 x 45 x 0.8mm at 406mm<br />

Floor track: 67 x 40 x 0.8mm (min.)<br />

Joint treatment of boards<br />

C STUD: 65mm X 45mm X 0.8mm<br />

at 406mm (min..)<br />

Floor Track: 67mm X 40mm X 0.8mm (min..)<br />

Self-tapping screws at 250mm<br />

Nominal centre<br />

<strong>KAPO</strong> Board has been appraised to be used as an interior lining relying on 400mm or 600mm stud centres or ceiling joist centres for framing and<br />

using either 6 or 9mm thick board. This appraisal is limited to the boards and nominated jointing systems only and excludes any finishing system,<br />

such as plastered finishes or tiling systems, which must comply with the relevant clauses of the New Zealand Building Code.<br />

65mm<br />

www.kapoboard.com 9


INSTALLATION FLOORING<br />

PARTITION & EXISTING FLOOR<br />

In filled insulation (glass<br />

fibre or rock wool)<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

C-STUD<br />

Tiles attach to <strong>KAPO</strong> after<br />

waterproof layer treatment<br />

Self-tapping screw<br />

Floor track<br />

Cartridge firing<br />

pin<br />

RC Concrete<br />

NOTE: For Time Underlayment<br />

10mm<br />

PARTITION OF BEDROOM & TOILET FLOOR<br />

50mm<br />

RC concrete<br />

Kitchen or Toilet side<br />

Bedroom side<br />

1. Steel tub must be more than 1.2mm thick, distance between each studs below 300mm.<br />

50mm<br />

75-100mm<br />

10mm<br />

Self-tapping screw<br />

C STUD<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

In filled insulation<br />

(Glass fibre or rock wool)<br />

Kick plate<br />

Floor track<br />

Silicone filler<br />

Existing finished flooring<br />

(Tiles, wood, marble, etc...)<br />

Cartridge firing pin<br />

2. Use self tapping stainless steel screws fix at 150mm centres below, screw head must be wider than screw hole.<br />

3. Reinforcement steel must be place at the back of the board if the tiled walls will be hanged with other materials (cannot be directly<br />

fix only on the board without (reinforcement).<br />

4 Sealants must be applied to cover adhesion must be strong enough to avoid delimitation and stripping.<br />

5 It is recommended to use boards in 12mm and above thickness.<br />

www.kapoboard.com 10


INSTALLATION R. C.<br />

CONCRETE CEILING<br />

Partition Wall & R. C. Ceiling<br />

10mm ~ 15mm<br />

50mm<br />

R. C. Concrete or beam<br />

Cartridge firing pin<br />

U-shape upper back<br />

Silicone filler<br />

Corner edge plate<br />

Self-tapping screw<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

C STUD<br />

In filled insulation<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

R. C. Concrete or beam<br />

Cartridge firing pin<br />

U-shaped upper track<br />

Self-tapping screw<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

C-Stud<br />

In filled insulation<br />

Suspension ceiling board<br />

INSTALLATION CORNER JOINT<br />

L-Corner Joint Cross Section 1<br />

Corner bar Floor track C STUD Corner bead C STUD Joint tape and joint filter<br />

Joint tape and joint filter<br />

Self tapping screw<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

In filled insulation<br />

In filled insulation<br />

Partition wall & R. C. + Suspension Ceiling<br />

Max. 50 mm<br />

Max. 50 mm<br />

L-Corner Joint Cross Section 2<br />

Floor track<br />

Self tapping screw<br />

50mm<br />

10mm ~ 15mm<br />

www.kapoboard.com 11


INSTALLATION “T” SECTION<br />

T - SECTION OF PARTITION WALL<br />

C STUD<br />

C-STUD at Min.<br />

65x35x1.0mm<br />

Floor track<br />

Self-tapping screw<br />

Joining tape and Joint compound<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

In filled insulation (Glass<br />

fiber or rock wool)<br />

Self-tapping screw<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

Floor Track<br />

Jointing Tape and<br />

Joint Compound<br />

In filled Insulation<br />

(Glass fiber or rock wool)<br />

INSTALLATION DOOR FRAME<br />

FIX TO STEEL DOOR FRAME<br />

In filled insulation<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

Max. 50mm<br />

Max. 50mm<br />

Self-tapping screw<br />

Spot-welded and treat<br />

with anti-rust Paint<br />

10mm<br />

Impact reinforcement<br />

piece of door frame<br />

Steel door frame<br />

Fasten by screws<br />

In filled insulation<br />

CROSSWISE SECTION OF PARTITION<br />

<strong>KAPO</strong> <strong>BOARD</strong><br />

C - Stud<br />

C-STUD at Min.<br />

65x35x1.0mm<br />

Self-tapping screw<br />

Spot-welded and treat<br />

with anti-rust Paint<br />

Max. 50mm<br />

Max. 50mm<br />

L-Corner Joint Cross Section 2<br />

Floor edge strip<br />

Elastic filler or silicone<br />

10mm<br />

Wood door frame<br />

Fasten by screw<br />

www.kapoboard.com 12


INSTALLATION FRAME REINFORCEMENT<br />

DOOR FRAME REINFORCEMENT (DOUBLE PILLAR TYPE)<br />

Door frame<br />

Window Opening Frame Reinforcement<br />

Window frame<br />

Fix by self-tapping screws<br />

C-STUD<br />

At min. 65 x 35 x 1.0mm<br />

Spot welding for joining 2 pillars<br />

(Treat with anti-rust paint)<br />

Fasten with self-Tapping Screws<br />

Upper rack<br />

C-STUD<br />

Bottom rack<br />

C-STUD (Welded together)<br />

Fasten by self-tapping screw<br />

Bottom rack<br />

C-STUD (Welded together)<br />

Fasten by self-tapping screw<br />

Bottom rack<br />

www.kapoboard.com 13


INSTALLATION DRY WALL<br />

INSTALLATION<br />

Galvanised steel channel sections, 30mm x 67mm x 30mm x 0.8mm thick, shall be fixed on the floor and<br />

ceiling, using 22mm anchor fixings, set at 600mm centers and inset 305mm from the vertical edges do the<br />

partition.<br />

Galvanised steel studding, 35mm x 65mm x 35mm x 0.8mm thick, Shall be installed vertically in the top and<br />

bottom track at 2400mm interval, allowing a 15mm gap at the top of each stud for expansion. The stud<br />

forming the restrained edge of the partition, shall fixed to frame using 22mm anchor fixings at 1,220mm<br />

centers inset 600mm ad 610mm from the top and bottom of the partition fixed (unstrained edge) as required<br />

by the standard.<br />

One layer of <strong>KAPO</strong> Board shall be fixed onto each face of the steel frame, with the joints on each face<br />

staggered by countersunk self-tapping screws, 4mm diameter x 25mm long, at nominally 400mm intervals.<br />

The boards shall not be fixed by any screws on the bottom frame on the floor.<br />

Slabs of mineral wool fiber shall be then cut to size and interference fitted into the steel channel sections<br />

such that original faces of Rock wool slab shall be parallel to the clad exposed face boards.<br />

Two layers of nominal 30mm thick mineral wool slabs shall be then interference fitted between the studs to<br />

give total thickness of 60mm (2x30mm) and a vertical displacement between horizontal joints.<br />

The unexposed face of the partition shall be then clad with nominal <strong>KAPO</strong> Super Mineral Board giving a<br />

lateral displacement between vertical of 610mm, and a vertical displacement of horizontal boards joints of<br />

2440mm.<br />

Gaps at all board joints, plus screw fixings at joint and intermediate position, shall be in filled and covered<br />

with fibrous adhesive, applied to give a board covering approximately 0.5mm thick in the immediate vicinity<br />

of the joints and fixings.<br />

1. Marking<br />

2. Fix the upper and bottom steel stud. (Fix the upper and bottom steel Stud)<br />

3. Installation of steel channel<br />

4. Installation of <strong>KAPO</strong> <strong>BOARD</strong><br />

www.kapoboard.com 14


Notes<br />

www.kapoboard.com 15


Notes<br />

www.kapoboard.com 16


Notes<br />

www.kapoboard.com 17


REACH US:<br />

Asia Pacific<br />

Dumi lokom Enterprise<br />

Unit 1 block C, 1st Floor,<br />

Sempuran Complex,<br />

Jalan Batu Bersurat, Gadong,<br />

Brunei Darussalam<br />

Tel : 673-244 8989, 673-242 2877<br />

Fax : 673-245 3581<br />

H/P : 673-871 2776, 673-871 3112<br />

Email : kklee@brunet.bn<br />

www.kapoboard.com<br />

North America<br />

Easy-Go Trading<br />

288 Green Moutain Road East,<br />

Stoney Creek, Ontario L8J 3A5<br />

Canada<br />

Tel : +1 647 282 0311<br />

Fax : +1 905 662 4859<br />

www.kapoboard.com<br />

Asia Pacific<br />

Dumi lokom Enterprise<br />

Unit 1 block C, 1st Floor,<br />

Sempuran Complex,<br />

Jalan Batu Bersurat, Gadong,<br />

Brunei Darussalam<br />

Tel : 673-244 8989, 673-242 2877<br />

Fax : 673-245 3581<br />

H/P : 673-871 2776, 673-871 3112<br />

Email : kklee@brunet.bn<br />

www.kapoboard.com<br />

www.kapoboard.com 18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!