478 Link <strong>Technical</strong><br />

wiring devices | white www.mkelectric.co.uk<br />

3 and 4 Pin Accessories/Pre-wired<br />

Standards and approvals<br />

BS 6972 & BS 5733<br />

Heat resisting three core circular cable BS 6972 & BS 5733 to<br />

BS 6500:2000 (table 29)<br />

low smoke zero halogen three core circular cable<br />

<strong>Technical</strong> <strong>specification</strong><br />

electrical<br />

Voltage rating:<br />

250V a.c. 50Hz<br />

Current rating:<br />

6 amp<br />

terminal Capacity (accessories)<br />

Phase, neutral, earth & ‘loop in’ terminals will each accept:<br />

K3230, K4230 – 1 x 0.75 or 1 x 1.00mm conductors<br />

K3220, K3212, K3240, K4220, K4214 and K4240 –<br />

5 x 0.75, 5 x 1.00, 4 x 1.50, 3 x 2.50 or 2 x 4.00mm 2<br />

conductors<br />

Physical<br />

Static Suspension load:<br />

5kg max<br />

ambient operating temperature:<br />

–5°C to +40°C<br />

(not to exceed an average of more than 25°C in any<br />

24 hour period)<br />

iP rating:<br />

iP2xD<br />

max. installation altitude:<br />

2000 metres<br />

dimensions<br />

25mm<br />

44mm<br />

25mm<br />

K3230, K3232, K3233<br />

35mm<br />

K4230, K4232, K4233<br />

57mm<br />

57mm<br />

description<br />

A connection and distribution system that<br />

brings convenience and versatility to lighting<br />

installations. The range consists of 80mm a modular dia.<br />

plug and socket interface which provides electrical<br />

connection in one easy click-in action. Luminaries<br />

can be plugged in without isolating the circuit.<br />

All live contacts are inaccessible and the earthing<br />

connection is made before any other.<br />

Wired products incorporate either heat resisting<br />

(WHR) or low smoke zero halogen (LSF) insulated 86mm<br />

75mm dia.<br />

and sheathed flexible 0.75mm four core circular<br />

cable.<br />

7mm<br />

Features<br />

● Live contacts are inaccessible<br />

● Earth Contact – first to make, last to<br />

break<br />

● Mechanical and <strong>Electric</strong>al Connection in<br />

58mm one ‘click-in’ action<br />

● Strong load grips support up to 5kg<br />

86mm<br />

Surface Flush (dryline)<br />

57mm<br />

Flush (solid)<br />

K3220/K3240 75mm dia. K3220/K4220/K4240WHI N/A N/A<br />

7mm K4214 K2160WHI QFB1WHI 861ZIC<br />

75mm dia.<br />

75mm dia.<br />

7mm<br />

MOUnTinG bOxES<br />

75mm dia.<br />

K3220<br />

80mm dia.<br />

75mm dia.<br />

44mm<br />

33mm<br />

86mm<br />

K4220 K4214<br />

58mm<br />

44mm<br />

33mm<br />

86mm<br />

86mm<br />

For a full range of corresponding products,<br />

see pages 72-76 in the product selector.<br />

25mm<br />

25mm<br />

44mm<br />

25mm<br />

75mm dia.<br />

75mm dia.<br />

7mm<br />

57mm<br />

75mm dia.<br />

75mm dia.<br />

44mm<br />

K3240, K3242, 3243<br />

K4240, K4242, 3443<br />

K3241<br />

44mm<br />

35mm<br />

25mm<br />

35mm<br />

80mm dia.<br />

80mm dia.<br />

86mm<br />

57mm<br />

57mm<br />

44mm<br />

58mm<br />

86mm<br />

58mm


L<br />

Distribution Boxes<br />

Standards and approvals<br />

BS 5733 'Local' lighting switch control<br />

Centralised emergency test via keyswitch<br />

<strong>Technical</strong> <strong>specification</strong><br />

electrical<br />

Current rating:<br />

6 amps<br />

terminal Capacity:<br />

3 x 6mm rated at 16 amps<br />

Physical<br />

'Local' lighting switch control<br />

Centralised emergency test via keyswitch<br />

Conduit entries Local with lighting snap switch<br />

E N L fit blanks;<br />

20 and 25mm in top, bottom and back faces.<br />

E<br />

description<br />

Distribution boxes consisting of an extruded aluminium body with VO rated plastic terminal housing.<br />

outlets to be Emergency wired as 1 or 2 blanks<br />

test switch<br />

Aux<br />

Loop<br />

Copper Link (2)<br />

Both 3 and 4 pin plugs can be used with the distribution box 4 pin socket outlets.<br />

ambient operating temperature:<br />

N<br />

–5°C to +40°C<br />

Sw(B)<br />

Sw(A)<br />

(not to exceed an average of more than 25°C in any 24<br />

To other<br />

installation<br />

LDS Box<br />

hour period)<br />

Zone lighting control<br />

Local iP rating: emergency test control<br />

iP2xD<br />

Local lighting switch<br />

Provision for screw (No. 8) fix to walls or trunking and slots for Caddy Clips* on top, bottom and back<br />

faces. Conduit entries with snap fit blanks; 20 and 25mm in top, bottom and back faces. Outlets can be<br />

wired as 1 or 2 banks.<br />

max. installation altitude: E<br />

2000 metres Aux<br />

Loop<br />

Remove Copper Link (2) *Caddy Clip is a registered trade mark of Erico<br />

Europa (UK) Ltd. Reading.<br />

For a full range of corresponding products,<br />

see pages 72-76 in the product selector.<br />

To lighting<br />

distribution<br />

board<br />

To lighting<br />

distribution<br />

board<br />

Sw(B) Local emergency test control<br />

Features<br />

E N L Sw(A)<br />

To other<br />

●<br />

LDS Box<br />

Fixing of distribution box to lighting E<br />

Aux<br />

trunking made easy through choice of Loop<br />

Zone switch to cable entry points<br />

● Sw(B)<br />

Distribution box can be suspended on<br />

Sw(A)<br />

drop rods or fitted to the wall or ceiling<br />

Emergency<br />

test switch N/C<br />

Wiring diagrams<br />

To lighting<br />

distribution<br />

board<br />

To lighting<br />

distribution<br />

board<br />

EARTH<br />

NEUTRAL<br />

LIVE<br />

other LDS Box<br />

SWITCH RETURN<br />

E N L<br />

Emergency<br />

test switch N/C<br />

N<br />

Zone lighting control<br />

EARTH<br />

NEUTRAL<br />

LIVE<br />

E<br />

Aux<br />

Loop<br />

N<br />

Sw(B)<br />

Sw(A)<br />

Zone switch to<br />

other LDS Box<br />

SWITCH RETURN<br />

Copper Link (2)<br />

N<br />

N<br />

Sw(B)<br />

Local lighting Sw(A) switch<br />

Local lighting switch<br />

E<br />

Aux<br />

Loop<br />

Remove Copper Link (2)<br />

To other<br />

LDS Box<br />

B<br />

'Local' lighting switch control<br />

Centralised emergency test via keyswitch<br />

Local lighting switch control<br />

Permanent E emergency N L feed<br />

To lighting<br />

distribution<br />

board<br />

E<br />

Emergency<br />

test switch<br />

N L<br />

Local lighting switch control<br />

E Permanent emergency feed<br />

Aux Copper Link (2)<br />

Loop<br />

Local lighting switch<br />

N<br />

Sw(B)<br />

Sw(A)<br />

Zone lighting control<br />

Local emergency test control<br />

Zone switch to<br />

other LDS Box<br />

To other<br />

LDS Box<br />

E<br />

Aux<br />

Loop<br />

N<br />

Sw(B)<br />

Sw(A)<br />

Local lighting switch control<br />

Permanent emergency feed<br />

E<br />

Aux<br />

Loop<br />

N<br />

Sw(B)<br />

Copper Sw(A) Link (2)<br />

dimensions (mm)<br />

Copper Link (2)<br />

Remove Copper Link (2)<br />

To other<br />

LDS Box<br />

To other<br />

LDS Box<br />

B<br />

To lighting<br />

distribution<br />

board<br />

B<br />

A<br />

A<br />

E N L<br />

Emergency<br />

test switch<br />

A<br />

Link <strong>Technical</strong><br />

technical hotline +44 (0)1268 563720 white | wiring devices<br />

'Local' lighting switch control<br />

Centralised emergency test via keyswitch<br />

Zone lighting control<br />

K4210 pictured<br />

Local lighting switch<br />

diMEnSiOnS (MM)<br />

a b<br />

K4204 237 222<br />

K4208 400 222<br />

K4210 465 222<br />

note: K4210 pictured<br />

E<br />

Aux<br />

Loop<br />

N<br />

Sw(B)<br />

Sw(A)<br />

Copper Link (2)<br />

To other<br />

LDS Box<br />

479