11.1 El-diagram<br />

12<br />

6 10<br />

BN<br />

SUPPLY<br />

3 x 230V-480V 50/60Hz<br />

4<br />

2<br />

U V W PE<br />

HIGH<br />

MIX<br />

WH GN<br />

13 14<br />

X1<br />

LOW<br />

MIX<br />

LOW<br />

CHEMI<br />

TEMP<br />

PUMP<br />

3<br />

0 1 I<br />

11<br />

7<br />

1A4<br />

BL<br />

1T3<br />

25VA<br />

21<br />

13<br />

5<br />

3<br />

1<br />

LOGO MODULE<br />

GY RD<br />

22<br />

14<br />

6<br />

4<br />

2<br />

1K7<br />

1.7<br />

11. El-install<strong>at</strong>ion<br />

1A<br />

SET PRESSURE<br />

24V<br />

U1 V1 W1¡í<br />

8<br />

X1<br />

18 19<br />

17<br />

15 16<br />

1<br />

1<br />

1Y6<br />

1H5<br />

1M0<br />

2<br />

2<br />

2<br />

3<br />

6 5 4<br />

L1 L2 L3<br />

A1<br />

1K7<br />

9<br />

M<br />

VALVE<br />

WATER SUPPLY<br />

RUNNING<br />

LAMP<br />

Kemipumpest<strong>at</strong>ion type <strong>KPV</strong> 16.08.10 /Side 29<br />

Version 4<br />

A2<br />

GRUNDFOS<br />

FREQ. CONVERTER<br />

0V<br />

7<br />

8<br />

SUPPLY<br />

PUMP<br />

1 2<br />

+ -<br />

4-20mA<br />

0-25bar<br />

press.transm.<br />

CHEMICAL PUMP<br />

WITH FREQ. CONVERTER