Følgende parametre kan indstilles vha. SP1:<br />

Det er kun tilladt at: Reducere Speed, Deceleration time og ændre<br />

Throttle gain.<br />

Front<br />

Fast Slow<br />

Forward Acceleration 40 30<br />

Forward Deceleration 8 5<br />

Re<strong>ver</strong>se acceleration 40 16<br />

Re<strong>ver</strong>se Deceleration 15 8<br />

Throttle Pol`ty? No *<br />

Power Down Time 10 *<br />

Read System Log? Code: ??<br />

Engineer Menu ?<br />

*<br />

Controller Type * *<br />

Compensation 5 *<br />

Brake Time 1500 *<br />

ISO Test ON *<br />

Throttle Gain 130% *<br />

Speed Control On *<br />

Pulse Rev Alarm No *<br />

Soft Stop YES *<br />

Throttle Deadband 10% *<br />

Output Voltage 24V *<br />

Trucharge Cable<br />

Resistance<br />

40m ohm *<br />

Trucharge Calibration 100 *<br />

Erase System Log No<br />

Back To Root ?<br />

Efter endt programmering<br />

slukkes scooteren på nøglen.<br />

Det 5 polede stik samles igen<br />

og scooteren kan tændes.<br />

<strong>Service</strong> <strong>manual</strong> P9-0155-S 25 af 70 Version 2.0.0/2010