Service manual Mini Crosser M1 ver. 2.00
Service manual Mini Crosser M1 ver. 2.00
Service manual Mini Crosser M1 ver. 2.00
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Medema Production A/S<br />
Følgende parametre kan indstilles vha. SP1:<br />
Det er kun tilladt at: Reducere Speed, Deceleration time og ændre<br />
Throttle gain.<br />
Front<br />
Fast Slow<br />
Forward Acceleration 40 30<br />
Forward Deceleration 8 5<br />
Re<strong>ver</strong>se acceleration 40 16<br />
Re<strong>ver</strong>se Deceleration 15 8<br />
Throttle Pol`ty? No *<br />
Power Down Time 10 *<br />
Read System Log? Code: ??<br />
Engineer Menu ?<br />
*<br />
Controller Type * *<br />
Compensation 5 *<br />
Brake Time 1500 *<br />
ISO Test ON *<br />
Throttle Gain 130% *<br />
Speed Control On *<br />
Pulse Rev Alarm No *<br />
Soft Stop YES *<br />
Throttle Deadband 10% *<br />
Output Voltage 24V *<br />
Trucharge Cable<br />
Resistance<br />
40m ohm *<br />
Trucharge Calibration 100 *<br />
Erase System Log No<br />
Back To Root ?<br />
Efter endt programmering<br />
slukkes scooteren på nøglen.<br />
Det 5 polede stik samles igen<br />
og scooteren kan tændes.<br />
<strong>Service</strong> <strong>manual</strong> P9-0155-S 25 af 70 Version 2.0.0/2010