Starting<br />

It is recommended that the slide of<br />

the intake nozzle is fully open or<br />

the nozzle removed from the material<br />

when starting the suction blower.<br />

Adjust the intake nozzle for maximum<br />

capacity when the blower has<br />

reached full speed.<br />

Lock the air intake regulator in<br />

starting position before starting the<br />

blower. The air intake regulator is<br />

limiting the blower’s air capacity in<br />

order to lower the load on the motor<br />

and thereby the consumption of<br />

amp during the start.<br />

Adjustment for<br />

maximum capacity<br />

The function of the slide is to ensure<br />

correct balance between air<br />

and grain.<br />

If the slide is open too far, there will<br />

be too much air and too little material<br />

conveyed.<br />

If the slide is closed too far, there<br />

will be too little air and the material<br />

will settle in the pipe system, and<br />

may block the pipe system completely.<br />

16<br />

Open<br />

Closed<br />

Open the slide on the intake nozzle<br />

fully and place the end of the intake<br />

nozzle in the material.<br />

Then slowly turn the slide on the<br />

intake nozzle from the fully open<br />

position towards the closed position.<br />

Note: It is only necessary to lock<br />

the air intake regulator if the reduction<br />

in amp consumption is<br />

demanded by the local power<br />

supply.<br />

Just before the pointer of the blower<br />

air regulator enters the red area<br />

the suction head slide is correctly<br />

adjusted.<br />

When the blower is fully running,<br />

release the air intake regulator<br />

again (<strong>SUC</strong> 300E/<strong>SUC</strong>500E can be<br />

delivered with automatically controlled<br />

air intake regulator).<br />

When working, the air intake regulator<br />

maintains a uniform air volume,<br />

even when the back pressure<br />

varies during operation. This reduces<br />

the load on the blower motor.<br />

The air intake regulator is sealed<br />

from the factory and must not be<br />

adjusted.<br />

Start<br />

Conveying