NeoTherm ® Gulvvarme<br />

Trådløs styring<br />

NeoTherm ® bruger- og monterings<strong>vejledning</strong><br />

DK


Indholdsfortegnelse<br />

Om NeoTherm ® Gulvvarme .........................................................................................................2<br />

Teknisk beskrivelse......................................................................................................................3<br />

Tekniske data...............................................................................................................................3<br />

Fordelerunit........................................................................................................................................................3<br />

Basisenhed (se særskilt manual i pakken)........................................................................................................3<br />

Termomotorer ....................................................................................................................................................3<br />

Rumtermostater .................................................................................................................................................3<br />

Montering ....................................................................................................................................4<br />

Fordelerunit........................................................................................................................................................4<br />

Termomotor........................................................................................................................................................4<br />

Basisenhed (se særskilt manual i pakken)........................................................................................................4<br />

Rumtermostater .................................................................................................................................................4<br />

Indregulering ...............................................................................................................................5<br />

Indreguleringsskema..........................................................................................................................................5<br />

Trådløs styring .............................................................................................................................6<br />

Indkodning .........................................................................................................................................................6<br />

Drift og vedligeholdelse ..............................................................................................................6<br />

Rumtermostat.....................................................................................................................................................6<br />

Temperaturvælger......................................................................................................................................................... 6<br />

Kugleomskifter .............................................................................................................................................................. 6<br />

Temperatursænkning "AUTOMATISK"............................................................................................................................ 6<br />

Basisenhed .........................................................................................................................................................7<br />

Sikring............................................................................................................................................................................ 7<br />

Diodeaktivitet................................................................................................................................................................ 7<br />

Pumpeshunt .......................................................................................................................................................7<br />

Termostatindstilling....................................................................................................................................................... 7<br />

Om NeoTherm ® Gulvvarme<br />

NeoTherm ® gulvvarme er et vandbåret gulvvarmeanlæg, der kan monteres hvor varmekilden er central- eller<br />

fjernvarme.<br />

NeoTherm ® gulvvarme giver en bedre og mere behagelig fordeling af varmen i rummet i forhold til radiatorvarme, der<br />

afgiver en koncentreret strålevarme.<br />

NeoTherm ® gulvvarme har en længere reaktionstid end traditionel opvarmning, specielt i betongulve hvor der er en<br />

stor flade, der skal varmes op/køles ned.<br />

Rumtermostaten måler temperaturen ved termostaten, hvilket kan betyde at indstillingen evt. skal stå et par grader<br />

over eller under den temperatur man ønsker, der hvor man opholder sig.<br />

Systemet består af:<br />

Fordelerunit: Fordeler det tempererede centralvarmevand ud i gulvvarmeslangerne<br />

Basisenhed: Koordinerende og styrende enhed<br />

Termomotorer: Åbner og lukker ventilerne<br />

Rumtermostater : Måler og videresender information om rumtemperatur til basisenhed<br />

Pumpeshunt: Blander og cirkulerer vandet (ikke påkrævet i alle installationer)<br />

Side 2


Teknisk beskrivelse<br />

NeoTherm ® fordelerunit er en samlet enhed for 2 til 12 afgreninger, som leveres enten med håndbetjente eller elregulerede<br />

ventiler. En manuel betjent unit kan senere forsynes med termomotorer uden at vandet skal tappes af<br />

anlægget.<br />

NeoTherm ® fordelerunit leveres komplet med ophængningsbeslag og omløbersæt til NeoPex gulvvarmerør.<br />

I fremløbsfordelerrøret er monteret særlige indreguleringsventiler, som skal indstilles efter rørlængder og ønsket<br />

effekt. (se afsnittet INDREGULERING)<br />

I returfordelerrøret er monteret ventiler, som bruges til at skrue op og ned for varmen i de enkelte gulvvarmerør.<br />

Tilslutningerne til gulvvarmerørene er standard for 20x2 mm NeoPex PE-RT-rør, men kan også leveres til andre<br />

dimensioner og rørtyper.<br />

Flere NeoTherm ® fordelerunit’s kan sammenbygges, hvis mere end 12 afgreninger er ønsket.<br />

Bemærk! Der er en begrænsning på 13 termomotorer pr. Basisenhed.<br />

Tekniske data<br />

Fordelerunit<br />

VVS-nr. manuel regulering:............................................................................................................................. 46 6558 0XX<br />

VVS-nr. el-regulering:...................................................................................................................................... 46 6558 1XX<br />

VVS-nr. trådløs regulering:.............................................................................................................................. 46 6558 2XX<br />

( XX = antal afgreninger )<br />

Materiale: ...................................................................................................................Afzinkningsfrit messing CuZn35Pb2<br />

Drifttemperatur: .................................................................................................................................................maks. 90ºC<br />

Drifttryk: ..........................................................................................................................................................maks. 10 bar<br />

Antal afgange:.......................................................................................................................................2 - 12 afgreninger<br />

Afgange ( standard ):.................................................................................................................3/4” Eurokonus x 20 mm<br />

Basisenhed (se særskilt manual i pakken)<br />

Termomotorer<br />

VVS-nr.............................................................................................................................................................. 46 6559 530<br />

Driftspænding...................................................................................................................................... 24 V AC/DC 0-60 Hz<br />

Maks. effekt ...................................................................................................................................................................2 W<br />

Strømforbrug ................................................................................................................................................ maks. 250 mA<br />

Tæthedsklasse..............................................................................................................................................................IP 54<br />

Luftfugtighed.....................................................................................................................maks. 80% (ej kondenserende)<br />

Rumtermostater<br />

VVS-nr.............................................................................................................................................................. 46 6559 620<br />

Båndbredde............................................................................................................................................................868 MHz<br />

Sendestyrke........................................................................................................................................................... < 10 mW<br />

Sendeinterval ......................................................................................................................................................9 – 10 min<br />

Sender rækkevidde............................................................................................................................ca. 30 m i bygninger<br />

Batteribestykning.........................................................................................................................................2 stk. 1,5 V AA<br />

Batterilevetid ...........................................................................................................................................................ca. 5 år<br />

Temperaturvælger........................................................................................................................................... 10 o C – 28 o C<br />

Temperaturmåler – afvigelse..............................................................................................................................maks. 1 o C<br />

Temperaturvælger - afvigelse ............................................................................................................................maks. 1 o C<br />

Luftfugtighed.....................................................................................................................maks. 80% (ej kondenserende)<br />

Mål..............................................................................................................................højde 79, bredde 93, dybde 27 mm<br />

Side 3


Montering<br />

Fordelerunit<br />

Side 4<br />

1. Fordeleruniten monteres på væggen i de medfølgende ophængningsbeslag<br />

2. Gulvvarmerør tilsluttes fordeleruniten med de medfølgende omløbersæt.<br />

Koblingen spændes til med hånden, derefter drejes 1,5 omgang med<br />

nøgle.<br />

3. NeoTherm ® fordelerunit kan nu tilsluttes varme-kilden, som af hensyn<br />

til både gulvets holdbarhed og gulvvarmeanlæggets<br />

reguleringskarakteristik ikke bør være over 45ºC. Dette kan opnås ved<br />

anvendelse af NeoTherm ® pumpeshunt.<br />

Termomotor<br />

1. Den lille pal fjernes med en lille skruetrækker<br />

2. Fjern metalpladen<br />

3. Drej håndhjulet af (venstre om)<br />

4. Ved hjælp af en skruetrækker fjernes den hvide adapter<br />

5. Den grå adapter trykkes på<br />

6. Termomotoren trykkes på<br />

7. Ledningerne forbindes til basisenheden<br />

Basisenhed (se særskilt manual i pakken)<br />

Rumtermostater<br />

• Rumtermostaten placeres på væggen ca. 30 cm fra døråbning.<br />

• Rumtermostaten må hverken være tildækket, placeret på en ydervæg eller i<br />

direkte sollys,<br />

Montér batterierne i termostaten, Husk + til + og – til - !<br />

1. Træk forsigtigt temperaturvælgeren af og drej låsen med en lille skrutrækker, så den<br />

står i position "OPEN"<br />

2. Skyd termostaten mod højre og træk den udad. Vrid ikke termostaten !<br />

3. Placér montagesoklen på væggen og spænd skruerne.<br />

4. Placér forsigtigt termostaten i sporene og skyd den mod venstre, indtil den dækker<br />

soklen. Pas på ikke at vride termostaten !<br />

5. Drej låseskruen med en lille skruetrækker til positionen "CLOSE", og sæt<br />

temperaturvælgeren på plads igen.


Indregulering<br />

Indregulering af gulvvarmeanlægget er nødvendigt for at opnå balance i anlægget.<br />

1. Start med at fjerne beskyttelseskappen øverst på fremløbsfordelerrøret.<br />

2. Med unbraconøglen (5 mm) drejes stilleskruen i bund. Derefter skrues<br />

stilleskruen det ønskede antal omgange tilbage fra ”lukket” (se<br />

indreguleringsskema).<br />

3. Gevindringen strammes let for at låse den korrekte forindstilling.<br />

4. Beskyttelseskappen sættes på igen.<br />

Indreguleringsskema<br />

1. Ventilen, der styrer den længste kreds, skal altid være helt åben.<br />

2. Find værdien der svarer til den længste kreds i skemaets øverste vandrette række.<br />

3. Brug den pågældende kolonne til bestemmelse af indstillingen for de øvrige kredse.<br />

Rørlængde for længste kreds<br />

120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45<br />

15 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 1 1 1/4 1 1/2 1 3/4 2<br />

20 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1/4 1 1/4 1 3/4 1 3/4 2 2 1/4 2 1/2<br />

25 3/4 3/4 3/4 3/4 3/4 1 1 1/4 1 1/4 1 1/2 1 3/4 1 3/4 2 2 1/4 2 1/2 2 1/2 3<br />

30 3/4 3/4 1 1 1 1/4 1 1/2 1 1/2 1 3/4 1 3/4 2 2 1/4 2 1/4 2 1/2 2 3/4 3 3 1/4<br />

35 1 1 1/4 1 1/4 1 1/2 1 1/2 1 3/4 1 3/4 2 2 1/4 2 1/4 2 1/2 2 1/2 3 3 3 1/4 3 3/4<br />

40 1 1/4 1 1/2 1 1/2 1 3/4 1 3/4 2 2 1/4 2 1/4 2 1/4 2 1/2 2 3/4 3 3 1/4 3 1/2 3 3/4 4 1/2<br />

45 1 3/4 1 3/4 1 3/4 2 2 2 1/4 2 1/4 2 1/2 2 1/2 2 3/4 3 3 1/4 3 1/2 4 4 1/2<br />

50 1 3/4 2 2 2 1/4 2 1/4 2 1/2 2 1/2 2 3/4 2 3/4 3 3 1/4 3 1/2 4 4 3/4<br />

55 2 2 1/4 2 1/4 2 1/4 2 1/2 2 1/2 2 3/4 3 3 3 1/4 3 3/4 4 4 3/4<br />

60 2 1/4 2 1/4 2 1/2 2 1/2 2 1/2 2 3/4 3 3 1/4 3 1/4 3 3/4 4 4 3/4<br />

65 2 1/4 2 1/2 2 1/2 2 3/4 2 3/4 3 3 1/4 3 1/2 3 3/4 4 4 3/4<br />

70 2 1/2 2 1/2 2 3/4 3 3 3 1/4 3 1/2 3 3/4 4 4 3/4<br />

75 2 3/4 2 3/4 3 3 3 1/4 3 1/2 3 3/4 4 1/4 4 3/4<br />

80 2 3/4 3 3 3 1/4 3 1/2 3 3/4 4 1/4 4 3/4<br />

85 3 3 1/4 3 1/4 3 1/2 3 3/4 4 1/4 4 3/4<br />

90 3 1/4 3 1/4 3 1/2 3 3/4 4 1/4 4 3/4<br />

95 3 1/4 3 3/4 3 3/4 4 1/4 4 3/4<br />

100 3 3/4 4 4 1/4 4 3/4<br />

105 4 4 1/2 4 3/4<br />

110 4 1/2<br />

115 4 3/4<br />

5<br />

Øvrige kredse<br />

BEMÆRK !<br />

Hvis man fornemmer at et rum er varmere eller koldere end man har indstillet rumtermostaten til, kan man prøve at<br />

skrue ned for et rum af gangen, og derved kontrollere om rumtermostaten er placeret i det korrekte rum i forhold til<br />

angivne varmekreds. Bliver der så koldere i dette rum, (måles efter mindst 1 døgn), må man antage at<br />

rumtermostaten er placeret korrekt.<br />

Side 5


Trådløs styring<br />

Indkodning<br />

Indkodning kan ske når basisenheden er monteret på væggen, og alle rumtermostater er pakket ud.<br />

Side 6<br />

1. Tænd for strømmen. Alle ”LED” vil herefter lyse konstant i 8 min og motorerne vil aktiveres. Anlægget er<br />

allerede nu klar til at indregulere.<br />

2. ”SET” på basisenheden holdes nede i ca. 5 sek. ”LED” for kreds 1 vil nu blinke hurtigt, ”SET” slippes. (Der er<br />

nu max. 3 min. til at udføre pkt. 3)<br />

3. På rumtermostat for kreds 1 trykkes nu med et enkelt tryk på ”SET” knappen der sidder under håndhjulet.<br />

"LED” vil nu igen lyse konstant og kreds 1 er klar.<br />

4. For at komme videre til kreds 2 holdes "SET" nede i ca. 5 sek. indtil "LED" for kreds 1 blinker. Knappen slippes<br />

og der trykkes igen 1 gang. ”LED” for kreds 2 vil nu blinke hurtigt ( følg derefter pkt. 3 ). For at indregulere<br />

kreds 3 holdes "SET" nede i ca. 5 sek. indtil "LED" for kreds 1 blinker. Knappen slippes og der trykkes igen 2<br />

gange. ”LED” for kreds 3 vil nu blinke hurtigt ( følg derefter pkt. 3 ).Osv.<br />

5. Når alle kredse er indreguleret vil basisenheden tvangsåbne samtlige telestater i ca. 15 min. Herefter vil<br />

anlægget stabilisere sig (gælder også efterfølgende ved f.eks. strømsvigt).<br />

Hvis man har behov for at starte indregulering forfra, skal styreenhed nulstilles. Dette gøres på følgende måde.<br />

� ”SET” på basisenheden holdes nede i ca. 5 sek. ”LED” for kreds 1 blinker, ”SET” slippes. Tryk straks igen på ”SET”<br />

og hold den nede. ”LED” for kreds 2 blinker og efter ca. 10 sek. blinker alle ”LED” kortvarigt, for herefter at<br />

gå ud. Når alle ”LED” er gået ud slippes ”SET”.<br />

� Nu er anlægget nulstillet og kort efter begynder alle ”LED” igen at lyse konstant. Nu følges pkt. 2-5 igen.<br />

Drift og vedligeholdelse<br />

Rumtermostat<br />

Temperaturvælger<br />

Drejeknap med "softklik" til indstilling af den ønskede temperatur.<br />

Hver streg svarer til 1 o C - ”3” = 19 o C<br />

Kugleomskifter<br />

� Temperatursænkning "TIL"<br />

Temperaturen bliver manuelt sænket 4 o , uafhængigt af eksterne signaler.<br />

0 Temperatursænkning FRA"<br />

Termostaten er i normal tilstand,<br />

og der vil ikke finde nogen sænkning sted.<br />

� Temperatursænkning "AUTOMATISK" (se nedenfor)<br />

Temperatursænkning "AUTOMATISK"<br />

Den "automatiske temperatur-sænkning" er på ca. 4 o i forhold til den bestemte værdi. Perioderne for sænkning kan<br />

programmeres ved hjælp af "TimerModulet" (ekstraudstyr).


Basisenhed<br />

Sikring<br />

Hvis indikatorlampen for sprunget sikring lyser skal sikringen skiftes. Dette gøres ved at fjerne låget ( de to skruer<br />

drejes en kvart omgang ) og udtage sikringsholderen.<br />

Der sidder en ny sikring (2 A flink) i låget.<br />

Diodeaktivitet<br />

Lysdioderne ud for hver kreds har følgende funktion:<br />

Normal drift udgang aktiv<br />

udgang inaktiv<br />

Batterispænding lav udgang aktiv<br />

udgang inaktiv<br />

Svagt radiosignal udgang aktiv<br />

Nødprogram - Batteri er tomt<br />

Programmeringstilstand<br />

Pumpeshunt<br />

udgang inaktiv<br />

Sek 0 0,5 1 2<br />

3 4<br />

For at opnå bedste komfort og økonomi bør man vælge at have en så lav temperatur på pumpeshunten som muligt,<br />

dog skal man sikre sig at temperaturen er tilstrækkelig høj til at kunne opvarme huset ( lav udetemperatur = høj<br />

gulvtemperatur). Temperaturen skal ligge mellem 35 o C og 45 o C.<br />

Termostatindstilling<br />

Skalaindstilling 1 2 3 4 5 6 7<br />

Temperatur 20 o C 25 o C 30 o C 35 o C 40 o C 45 o C 50 o C<br />

Hvis man fornemmer at varmen i gulvet svinger fra meget varmt gulv til meget koldt gulv, kan man med fordel skrue<br />

ned for Termostatventilen på Pumpeshunten. Her skal man huske på at selv om man har installeret gulvvarme i sit<br />

hus, er det ikke ensbetydende med, at gulvene altid er varme.<br />

Hvis der er monteret et pumpemodul, vil pumpen kun køre, når der er varmebehov. Dette giver en lille besparelse på<br />

el-budgettet, og beskyttelse af pumpen.<br />

I sommerperioden kan man vælge helt at slukke for varmen ved at afbryde strømmen til basismodtageren og<br />

cirkulationspumpen. Anlægget startes op igen ved at tænde for strømmen.<br />