17.01.2013 Views

MAV 0921-5 RE 10 031018 SE DE GB - nibe.com

MAV 0921-5 RE 10 031018 SE DE GB - nibe.com

MAV 0921-5 RE 10 031018 SE DE GB - nibe.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SE</strong><br />

<strong>GB</strong><br />

<strong>DE</strong><br />

<strong>MAV</strong> <strong>0921</strong>-5<br />

<strong>RE</strong> <strong>10</strong><br />

03<strong>10</strong>18<br />

MONTERINGSANVISNING RUM<strong>SE</strong>NHET <strong>RE</strong> <strong>10</strong><br />

INSTALLATION INSTRUCTIONS ROOM UNIT <strong>RE</strong> <strong>10</strong><br />

MONTAGEANWEISUNG RAUMEINHEIT <strong>RE</strong> <strong>10</strong><br />

LEK<br />

<strong>RE</strong> <strong>10</strong><br />

<strong>RE</strong>


Allmänt<br />

Rumsenhet <strong>RE</strong> <strong>10</strong> fungerar som en extern display med<br />

inbyggd rumsgivare till F360P / F1135 / F1150 / F1235 /<br />

F1250 / ACVM 270 / VVM 300 / SMO <strong>10</strong>. Med <strong>RE</strong> <strong>10</strong><br />

kan man läsa och ändra menyer och värden som finns<br />

tillgängliga i värmepumpen/elpannan/styrmodulen. Med<br />

den inbyggda rumsgivaren korrigeras den beräknade<br />

framledningen från värmepumpen/elpannan på ett sätt<br />

som gör att rumstemperaturen kan hållas på en konstant<br />

nivå i rummet.<br />

Innehåll<br />

1 st Displayenhet<br />

1 st T-skarvkontakt RJ 45, modular<br />

1 st 3 m Modularkabel<br />

1 st 15 m Modularkabel<br />

1 st Batterieliminator för montering inomhus<br />

(230 V AC / 12 V DC 6 W)<br />

1 st Temperaturgivare (förmonterad på displaykortet)<br />

Mått<br />

130<br />

205<br />

MONTERINGSANVISNING<br />

<strong>RE</strong> <strong>10</strong><br />

44<br />

50<br />

<strong>RE</strong> <strong>10</strong><br />

Ø <strong>10</strong><br />

Ø 4<br />

120<br />

1


<strong>SE</strong><br />

Anslutning<br />

Installation av <strong>RE</strong> <strong>10</strong> sker enligt principschemat längst<br />

ner på sidan:<br />

OBS!<br />

Kontrollera att värmepumpen/elpannan/<br />

styrmodulen är strömlös innan ingrepp<br />

görs bakom fastskruvade luckor.<br />

De medföljande modularkablarna är inte beroende av<br />

en speciell modularkontakt utan kan skiftas efter önskad<br />

placering av T-skarvskontakten.<br />

1. Öppna plastkapseln och anslut modularkabel mellan<br />

X1 på T-skarvkontakten och ledig modularkontakt<br />

i F360P / F1135 / F1150 / F1235 / F1250 /<br />

ACVM 270 / VVM 300 / SMO <strong>10</strong> (utpekade i bild<br />

på nästa sida).<br />

2. Anslut nästa modularkabel mellan X2 på T-skarvkontakten<br />

och någon av modularkontakterna på<br />

<strong>RE</strong> <strong>10</strong> (se bild till höger). Modularkabeln kan anslutas<br />

antingen underifrån eller rakt bakifrån.<br />

För att underlätta anslutning kan kåpan på displayenheten<br />

skruvas loss enligt ”Alternativ givarplacering”<br />

på nästa uppslag.<br />

3. Anslut batterieliminatorn till X3 på T-skarvkontakten<br />

och stäng plastkapseln.<br />

4. Anslut batterieliminatorn till eluttag.<br />

Principschema<br />

<strong>RE</strong> <strong>10</strong><br />

3 alt. 15 m<br />

T-skarv<br />

X2 X1<br />

1,5 m<br />

X3<br />

2 <strong>RE</strong> <strong>10</strong><br />

<strong>RE</strong> <strong>10</strong> (baksida)<br />

OBS!<br />

All elektrisk inkoppling bakom fastskruvade<br />

luckor skall ske av behörig elektriker.<br />

Elektrisk installation och ledningsdragning<br />

skall utföras enligt gällande bestämmelser.<br />

15 alt. 3 m<br />

F1235/F1250


LEK<br />

F1135/F1150<br />

F360P<br />

VVM 300<br />

F1120-30 cope<br />

LEK<br />

LEK<br />

Modularkontakter<br />

ACVM 270<br />

<strong>RE</strong> <strong>10</strong><br />

GM20<br />

HQ1<br />

F1235/F1250<br />

XL4 XL3 XL2 XL1 XL15 XL13 XL14 PF4 PF1<br />

Utan tillbehör<br />

UB1<br />

UB2<br />

EP2<br />

X1<br />

SMO <strong>10</strong><br />

<strong>SE</strong><br />

3<br />

LEK


<strong>SE</strong><br />

Alternativ givarplacering<br />

<strong>RE</strong> <strong>10</strong> har inbyggd rumstemperaturgivare. Denna kan<br />

skarvas och förlängas om man önskar mäta rumstemperaturen<br />

på en mer representativ plats i huset.<br />

1. Skruva loss de två skruvarna som håller plastkåpan.<br />

2. Skruva loss de fyra skruvarna på rumsenhetens baksida.<br />

3. Avlägsna monterad givare på fjäderplint J3 och anslut<br />

ny skarvad kabel.<br />

1 2 3<br />

LEK<br />

OBS!<br />

Elektrisk installation och ledningsdragning<br />

skall utföras enligt gällande bestämmelser.<br />

4 <strong>RE</strong> <strong>10</strong><br />

J3<br />

Inställningar<br />

■ Välj ”Service” i meny 8.1.1 för att få tillgång till<br />

meny 9.0 och dess undermenyer.<br />

Om F360P<br />

■ Välj ”<strong>RE</strong><strong>10</strong>” i meny 9.1.14 och därmed är meny 6.0<br />

tillgänglig. I undermenyerna på 6.0 görs inställningar<br />

för önskad rumstemperatur etc. (se MOS för 360P<br />

för mer information).<br />

Om F1135/F1150/F1235/F1250<br />

■ Välj ”Till” i meny 9.2.6, ”Rumsenhet” i meny 9.2.18<br />

och därmed är meny 6.0 tillgänglig. I undermenyerna<br />

på 6.0 görs inställningar för önskad rumstemperatur<br />

etc. (se MOS för 1135/1150/1235/1250 för<br />

mer information).<br />

Om ACVM 270<br />

■ Välj ”Till” i meny 9.3.5 för att aktivera <strong>RE</strong><strong>10</strong>.<br />

■ Välj ”<strong>RE</strong><strong>10</strong>” i meny 9.3.6 och därmed är meny 6.0<br />

tillgänglig. I undermenyerna på 6.0 görs inställningar<br />

för önskad rumstemperatur etc. (Se MOS för ACVM<br />

270 för mer information).<br />

Om SMO <strong>10</strong>/VVM 300<br />

■ Välj ”Till” i meny 9.3.4 och därmed är meny 6.0<br />

tillgänglig. I undermenyerna på 6.0 görs inställningar<br />

för önskad rumstemperatur etc. (Se MOS för SMO<br />

<strong>10</strong> / VVM 300 för mer information.)


General<br />

Room unit <strong>RE</strong> <strong>10</strong> functions as an external display with<br />

integrated room sensor for F360P / F1140 / F1150 /<br />

F1240 / F1250 / ACVM 270 / VVM 300 / SMO <strong>10</strong>. The<br />

<strong>RE</strong> <strong>10</strong> can be used to read and modify menus and values<br />

which are accessible in the heat pump/electric boiler/<br />

control module. With the integrated room sensor the<br />

calculated flow line is corrected from the heat pump/<br />

electric boiler in a way that means that the room temperature<br />

can be held at a constant level in the room.<br />

Contents<br />

1 x Display unit<br />

1 x T-extension connector RJ 45, modular<br />

1 x 3 m Modular cable<br />

1 x 15 m Modular cable<br />

1 x Battery eliminator for installation indoors<br />

(230 V AC / 12 V DC 6 W)<br />

1 x Temperature sensor (pre-installed on the display card)<br />

Dimensions<br />

130<br />

205<br />

INSTALLATION INSTRUCTIONS<br />

<strong>RE</strong> <strong>10</strong><br />

44<br />

50<br />

<strong>RE</strong> <strong>10</strong><br />

Ø <strong>10</strong><br />

Ø 4<br />

120<br />

5


<strong>GB</strong><br />

Connection<br />

<strong>RE</strong> <strong>10</strong> is installed according to the outline diagram at<br />

the bottom of the page:<br />

Note!<br />

Check that the heat pump/electric boiler/<br />

control module is unpowered before work<br />

is carried out behind covers secured by<br />

screws.<br />

The modular cables supplied are not dependent on a<br />

special modular connection but can be moved to the<br />

desired location of the T-connector.<br />

1. Open the plastic cover and connect the modular<br />

cable between X1 on the T-connection and the free<br />

modular connection in F360P / F1140 / F1240 /<br />

F1250 / ACVM 270 / VVM 300 / SMO <strong>10</strong> (shown in<br />

the image on the next page).<br />

2. Connect the next modular cable between X2 on<br />

the T-connector and any of the modular connectors<br />

on <strong>RE</strong> <strong>10</strong> (see image to right). The modular<br />

cable can be connected either from underneath or<br />

straight behind.<br />

To simplify the connection, the cover of the display<br />

unit can be unscrewed according to ”Alternative<br />

sensor positioning” in the next entry.<br />

3. Connect the battery eliminator to X3 on the T-connection<br />

and close the plastic cover.<br />

4. Connect the battery eliminator to the power socket.<br />

Outline Diagram<br />

<strong>RE</strong> <strong>10</strong><br />

3 or 15 m<br />

T-connection<br />

X2 X1<br />

1.5 m<br />

X3<br />

6 <strong>RE</strong> <strong>10</strong><br />

<strong>RE</strong> <strong>10</strong> (rear side)<br />

Note!<br />

All electrical connections behind covers<br />

secured by screws must be carried out by<br />

an authorised electrician.<br />

Electrical installation and wiring must be<br />

carried out in accordance with the stipulations<br />

in force.<br />

15 or 3 m<br />

F1240/F1250


LEK<br />

F1140/F1150<br />

F360P<br />

VVM 300<br />

F1120-30 cope<br />

LEK<br />

LEK<br />

Modular switches<br />

ACVM 270<br />

<strong>RE</strong> <strong>10</strong><br />

GM20<br />

HQ1<br />

F1240/F1250<br />

XL4 XL3 XL2 XL1 XL15 XL13 XL14 PF4 PF1<br />

Utan tillbehör<br />

UB1<br />

UB2<br />

EP2<br />

X1<br />

SMO <strong>10</strong><br />

<strong>GB</strong><br />

7<br />

LEK


<strong>GB</strong><br />

Alternative sensor positioning<br />

<strong>RE</strong> <strong>10</strong> has an integrated room temperature sensor. This<br />

can be spliced and extended if one wishes to measure<br />

the room temperature in a more representative location<br />

in the house.<br />

1. Slacken off the two screws holding the plastic<br />

cover.<br />

2. Unscrew the four screws on the rear side of the<br />

room unit.<br />

3. Remove the installed sensor on spring terminal J3<br />

and connect the new spliced cable.<br />

1 2 3<br />

LEK<br />

Note!<br />

Electrical installation and wiring must be<br />

carried out in accordance with the stipulations<br />

in force.<br />

8 <strong>RE</strong> <strong>10</strong><br />

J3<br />

Settings<br />

■ Select “Service” in menu 8.1.1 to gain access to<br />

menus 9.0 and the sub-menus.<br />

About F360P<br />

■ Select “Room unit” in menu 9.1.4 and menu 6.0<br />

be<strong>com</strong>es available. Settings for desired room temperature<br />

etc can be selected in the sub-menus to<br />

6.0. (see MOS for 360P for more information).<br />

About F1140/F1150/F1240/F1250<br />

■ Select “On” in menu 9.2.6, “Room unit” in<br />

menu 9.2.18 and menu 6.0 be<strong>com</strong>es available.<br />

Settings for desired room temperature etc can be<br />

selected in the sub-menus to 6.0. (see MOS for<br />

1140/1150/1240/1250 for more information).<br />

About ACVM 270<br />

■ Select ”On” in menu 9.3.5 to activate <strong>RE</strong><strong>10</strong>.<br />

■ Select “<strong>RE</strong><strong>10</strong>” in menu 9.3.6 and menu 6.0 be<strong>com</strong>es<br />

available. Settings for desired room temperature<br />

etc can be selected in the sub-menus to 6.0. (see MOS<br />

for ACVM 270 for more information).<br />

About SMO <strong>10</strong>/VVM 300<br />

■ Select “On” in menu 9.3.4 and menu 6.0 be<strong>com</strong>es<br />

available. Settings for desired room temperature etc<br />

can be selected in the sub-menus to 6.0. (see MOS<br />

for SMO <strong>10</strong> / VVM300 for more information).


Allgemeines<br />

Raumeinheit <strong>RE</strong> <strong>10</strong> fungiert als externes Display mit integriertem<br />

Raumfühler für F360P / F1140 / F1150 / F1240<br />

/ F1250 / ACVM 270 / VVM 300 / SMO <strong>10</strong>. Über <strong>RE</strong> <strong>10</strong><br />

lassen sich Menüs und Werte anzeigen und ändern, die<br />

für Wärmepumpe/Elektrokessel/Steuermodul verfügbar<br />

sind. Mithilfe des integrierten Raumfühlers wird die<br />

berechnete Vorlauftemperatur von der Wärmepumpe<br />

bzw. vom Elektrokessel so korrigiert, dass im Raum eine<br />

konstante Temperatur vorliegt.<br />

Lieferumfang<br />

1 Displayeinheit<br />

1 modularer T-Verbindungskontakt, RJ 45<br />

1 Modularkabel (3 m)<br />

1 Modularkabel (15 m)<br />

1 Batterieersatzgerät zur Montage im Innenbereich<br />

(230 V WS/12 V GS, 6 W)<br />

1 Fühler (an der Displaykarte vormontiert)<br />

Maße<br />

130<br />

205<br />

MONTAGEANLEITUNG<br />

<strong>RE</strong> <strong>10</strong><br />

44<br />

50<br />

<strong>RE</strong> <strong>10</strong><br />

Ø <strong>10</strong><br />

Ø 4<br />

120<br />

9


<strong>DE</strong><br />

Anschluss<br />

Die Installation von <strong>RE</strong> <strong>10</strong> erfolgt gemäß der<br />

Prinzipskizze unten auf der Seite:<br />

Hinweis:<br />

Stellen Sie vor Eingriffen hinter festverschraubten<br />

Abdeckungen sicher, dass<br />

die Stromversorgung für Wärmepumpe/<br />

Elektrokessel/Steuermodul unterbrochen<br />

wurde.<br />

Die beiliegenden Modularkabel sind nicht für einen<br />

speziellen Modularkontakt vorgesehen, sondern<br />

können je nach gewünschter Anbringung des T-<br />

Verbindungskontakts umgesetzt werden.<br />

1. Öffnen Sie das Kunststoffgehäuse und verbinden<br />

Sie das Modularkabel mit X1 am<br />

T-Verbindungskontakt und einem freien<br />

Modularkontakt an F360P / F1140 / F1150 / F1240<br />

/ F1250 / ACVM 270 / VVM 300 / SMO <strong>10</strong> (siehe<br />

Abbildung auf der nächsten Seite).<br />

2. Verbinden Sie das nächste Modularkabel mit<br />

X2 am T-Verbindungskontakt und einem der<br />

Modularkontakte an <strong>RE</strong> <strong>10</strong> (siehe Abbildung zur<br />

Rechten). Das Modularkabel kann von unten oder<br />

gerade von hinten angeschlossen werden.<br />

Um den Anschluss zu erleichtern, kann die<br />

Abdeckung der Displayeinheit abgeschraubt werden,<br />

siehe ”Alternative Fühlerpositionierung” unten.<br />

3. Verbinden Sie das Batterieersatzgerät mit X3<br />

am T-Verbindungskontakt und schließen Sie das<br />

Kunststoffgehäuse.<br />

4. Verbinden Sie das Batterieersatzgerät mit dem<br />

Stromanschluss.<br />

Prinzipskizze<br />

*Gesamt Maximal 18 m.<br />

<strong>RE</strong> <strong>10</strong><br />

3 bzw. 15 m *<br />

T-Verbindung<br />

X2 X1<br />

1,5 m<br />

<strong>10</strong> <strong>RE</strong> <strong>10</strong><br />

X3<br />

<strong>RE</strong> <strong>10</strong> (Rückseite)<br />

Hinweis:<br />

Alle elektrischen Anschlüsse hinter festverschraubten<br />

Abdeckungen müssen von einem<br />

befugten Elektriker ausgeführt werden.<br />

Bei der elektrischen Installation und beim<br />

Verlegen der Leitungen sind die geltenden<br />

Vorschriften zu berücksichtigen.<br />

15 bzw. 3 m *<br />

F1240/F1250


LEK<br />

F1140/F1150<br />

F360P<br />

VVM 300<br />

F1120-30 cope<br />

LEK<br />

LEK<br />

Modular Modularkontakte switches<br />

ACVM 270<br />

<strong>RE</strong> <strong>10</strong><br />

GM20<br />

HQ1<br />

F1240/F1250<br />

XL4 XL3 XL2 XL1 XL15 XL13 XL14 PF4 PF1<br />

Utan tillbehör<br />

UB1<br />

UB2<br />

EP2<br />

X1<br />

SMO <strong>10</strong><br />

<strong>DE</strong><br />

11<br />

LEK


<strong>DE</strong><br />

Alternative Fühlerpositionierung<br />

<strong>RE</strong> <strong>10</strong> besitzt einen integrierten Raumfühler. Dieser<br />

kann verbunden und verlängert werden, wenn die<br />

Raumtemperatur an einer anderen Stelle im Haus gemessen<br />

werden soll.<br />

1. Lösen Sie die beiden Schrauben zur Befestigung der<br />

Kunststoffabdeckung.<br />

2. Lösen Sie die vier Schrauben an der Rückseite der<br />

Raumeinheit.<br />

3. Entfernen Sie den montierten Fühler an<br />

Federklemme J3 und bringen Sie ein neues<br />

Verbindungskabel an.<br />

1 2 3<br />

LEK<br />

Hinweis:<br />

Bei der elektrischen Installation und beim<br />

Verlegen der Leitungen sind die geltenden<br />

Vorschriften zu berücksichtigen.<br />

12 <strong>RE</strong> <strong>10</strong><br />

J3<br />

Einstellungen<br />

■ Durch Auswahl von "Service" in Menü 8.1.1 erhalten<br />

Sie Zugriff auf Menü 9.0 und die zugehörigen<br />

Untermenüs.<br />

F360P<br />

■ Wählen Sie ”Raumeinheit“ in Menü 9.1.14 um auf<br />

Menü 6.0 zugreifen zu können. In den Untermenüs<br />

zu Menü 6.0 werden die Einstellungen für die gewünschte<br />

Raumtemperatur usw. vorgenommen.<br />

(Weitere Informationen entnehmen Sie den entsprechenden<br />

Bedienungs- und Montageanleitungen für<br />

Modell 360P.)<br />

F1140/F1150/F1240/F1250<br />

■ Wählen Sie ”Ein” in Menü 9.2.6 und ”Raumeinheit“<br />

in Menü 9.2.18 um auf Menü 6.0 zugreifen<br />

zu können. In den Untermenüs zu Menü 6.0<br />

werden die Einstellungen für die gewünschte<br />

Raumtemperatur usw. vorgenommen. (Weitere<br />

Informationen entnehmen Sie den entsprechenden<br />

Bedienungs- und Montageanleitungen für Modell<br />

1140/1150/1240/1250.)<br />

ACVM 270<br />

■ Wählen Sie ”Ein” im Menü 9.3.5 um <strong>RE</strong><strong>10</strong> zu aktivieren.<br />

■ Wählen Sie ”<strong>RE</strong><strong>10</strong>” in Menü 9.3.6 aus, um auf<br />

Menü 6.0 zugreifen zu können. In den Untermenüs<br />

zu Menü 6.0 werden die Einstellungen für die gewünschte<br />

Raumtemperatur usw. vorgenommen.<br />

(Weitere Informationen entnehmen Sie den entsprechenden<br />

Bedienungs- und Montageanleitungen für<br />

ACVM 270.)<br />

■ SMO <strong>10</strong>/VVM 300<br />

■ Wählen Sie ”Ein” in Menü 9.3.4 aus, um auf Menü<br />

6.0 zugreifen zu können. In den Untermenüs zu<br />

Menü 6.0 werden die Einstellungen für die gewünschte<br />

Raumtemperatur usw. vorgenommen.<br />

(Weitere Informationen entnehmen Sie den entsprechenden<br />

Bedienungs- und Montageanleitungen für<br />

SMO <strong>10</strong>/VVM 300.)


AT<br />

CH<br />

CZ<br />

<strong>DE</strong><br />

DK<br />

FI<br />

<strong>GB</strong><br />

NL<br />

NO<br />

PL<br />

KNV Energietechnik GmbH, Gahberggasse 11, 4861 Schörfling<br />

Tel: +43 (0)7662 8963-0 Fax: +43 (0)7662 8963-44 E-mail: mail@knv.at www.knv.at<br />

NIBE Wärmetechnik AG, Winterthurerstrasse 7<strong>10</strong>, CH-8247 Flurlingen<br />

Tel: (52) 647 00 30 Fax: (52) 647 00 31 E-mail: info@<strong>nibe</strong>.ch www.<strong>nibe</strong>.ch<br />

Druzstevni zavody Drazice s.r.o, Drazice 69, CZ - 294 71 Benatky nad Jizerou<br />

Tel: +420 326 373 801 Fax: +420 326 373 803 E-mail: <strong>nibe</strong>@<strong>nibe</strong>.cz www.<strong>nibe</strong>.cz<br />

NIBE Systemtechnik GmbH, Am Reiherpfahl 3, 29223 Celle<br />

Tel: 05141/7546-0 Fax: 05141/7546-99 E-mail: info@<strong>nibe</strong>.de www.<strong>nibe</strong>.de<br />

Vølund Varmeteknik, Filial af NIBE AB, Brogårdsvej 7, 6920 Videbæk<br />

Tel: 97 17 20 33 Fax: 97 17 29 33 E-mail: info@volundvt.dk www.volundvt.dk<br />

NIBE – Haato OY, Valimotie 27, 015<strong>10</strong> Vantaa<br />

Puh: 09-274 697 0 Fax: 09-274 697 40 E-mail: info@haato.<strong>com</strong> www.haato.fi<br />

NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG<br />

Tel: 0845 095 1200 Fax: 0845 095 1201 E-mail: info@<strong>nibe</strong>.co.uk www.<strong>nibe</strong>.co.uk<br />

NIBE Energietechniek B.V., Postbus 2, NL-4797 ZG WILLEMSTAD (NB)<br />

Tel: 0168 477722 Fax: 0168 476998 E-mail: info@<strong>nibe</strong>nl.nl www.<strong>nibe</strong>nl.nl<br />

NIBE AB, Fekjan 15F, 1394 Nesbru<br />

Tel: 22 90 66 00 Fax: 22 90 66 09 E-mail: info@<strong>nibe</strong>.se www.<strong>nibe</strong>-villavarme.no<br />

NIBE-BIAWAR Sp. z o. o. Aleja Jana Pawła II 57, 15-703 BIAŁYSTOK<br />

Tel: 085 662 84 90 Fax: 085 662 84 14 E-mail: sekretariat@biawar.<strong>com</strong>.pl www.biawar.<strong>com</strong>.pl<br />

NIBE AB Sweden, Box 14, Järnvägsgatan 40, <strong>SE</strong>-285 21 Markaryd<br />

Tel: +46-(0)433-73 000 Fax: +46-(0)433-73 190 E-mail: info@<strong>nibe</strong>.se www.<strong>nibe</strong>.eu

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!