ELP-362D Emergency Locator Beacon User's ... - Teledyne Benthos
ELP-362D Emergency Locator Beacon User's ... - Teledyne Benthos
ELP-362D Emergency Locator Beacon User's ... - Teledyne Benthos
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>ELP</strong>-<strong>362D</strong> <strong>Emergency</strong> <strong>Locator</strong> <strong>Beacon</strong> 5<br />
TSO Testing Qualification Summary<br />
The beacon is designed to meet the performance specifications of RTCA D-160,<br />
as required by TSO-C121. A summary of the testing qualifications is presented<br />
in the table below.<br />
<strong>ELP</strong>-<strong>362D</strong> TSO Testing Qualification Summary<br />
Testing Conditions<br />
RTCA D-160<br />
Section No.<br />
Altitude 4.6.1<br />
Decompression 4.6.2<br />
Overpressure 4.6.3<br />
Vibration 8.0<br />
Description of Test<br />
Conducted<br />
Equipment tested to Category D<br />
(50,000 ft.)<br />
Equipment tested to RTCA<br />
DO-160D Figure 8-2<br />
Curve J (Fixed Wing) and<br />
Figure 8-4 Curve Y (Rotary Wing)<br />
Sand and Dust 12.0 Equipment tested to Category D<br />
Fungus 13.0 Equipment tested to Category F<br />
Salt Spray 14.0 Equipment tested to Category S<br />
Magnetic Effect 15.0 Equipment tested to Category Z<br />
Induced Signal<br />
Susceptibility<br />
19.0 N/A<br />
Other Tests — Performance, environmental and<br />
Crash Survivability Testing<br />
performed as required by<br />
AS 8045.<br />
User’s Manual June 2011