Automatic<br />
circuit-breaker<br />
RCCB circuit-breaker<br />
(only <strong>726</strong> 72)<br />
Reverse-polarity control<br />
lamp<br />
2. Description<br />
1Mains switch<br />
5<br />
2<br />
0<br />
PE<br />
4<br />
1<br />
<strong>726</strong> <strong>71</strong><br />
2Residual-current-operated circuit-breaker 30 mA, (only <strong>726</strong> 72)<br />
3Automatic circuit-breaker 10 A<br />
4Phase control lamp L1,<br />
to monitor the voltage at the connection socket L1<br />
5Reverse-polarity control lamp,<br />
lights up when the mains plug is connected with the wrong polarity<br />
6Connection socket L1<br />
7Connection socket N<br />
8PE connection socket<br />
3. Operation<br />
If the automatic circuit-breaker is tripped out during overload of the experiment setup:<br />
• Disconnect experiment setup from the mains by switching the mains switch to [OFF]<br />
• Correct fault source<br />
• Reset the automatic circuit-breaker by setting the switch to [I]<br />
Test the function of the RCCB:<br />
• Set mains switch to [ON]<br />
• Press the pushbutton [T] on the RCCB circuit-breaker<br />
• If the RCCB circuit-breaker is tripped, operation is guaranteed.<br />
If the RCCB circuit-breaker is tripped by a fault current in the experiment setup<br />
• Disconnect the experiment setup from the mains by switching the mains switch to [OFF]<br />
• Correct fault source<br />
• Reset the RCCB circuit-breaker by setting the switch to [I]<br />
If the reverse-polarity control lamp lights up:<br />
• Pull out the mains plug<br />
• Replug the mains plug with the correct polarity (rotate)<br />