ACCUMAX® Premises Distribution Cable Brochure - Ofs
ACCUMAX® Premises Distribution Cable Brochure - Ofs
ACCUMAX® Premises Distribution Cable Brochure - Ofs
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
The ACCUMAX Plenum-Rated <strong>Distribution</strong> <strong>Cable</strong> offers<br />
an ideal choice for plenum applications including fi berto-the-desktop.<br />
ACCUMAX <strong>Cable</strong> featuring LaserWave ®<br />
ACCUMAX Plenum-Rated <strong>Cable</strong><br />
Multimode Fiber is specifi cally designed for:<br />
• Seamless Migration – Supports continuous migration<br />
from 10 Mbps to 10 Gbps with no cabling system<br />
changes up to 300 meters<br />
• Lower Installation Costs – Enables lowest cost<br />
for legacy through 10-GBps applications, helping to<br />
reduce total system cost by 25% or more<br />
• Improved Cabling System Administration – Saves<br />
time, using a single cable type which speeds cabling<br />
system administration<br />
Note: Other elements specifi c to multitube<br />
cables not depicted here<br />
[Unit (Tube) Jacket (PVDF) and<br />
Organizers (PVDF)]<br />
ACCUMAX Plenum-Rated <strong>Cable</strong> – Specifications and Handling<br />
• Reduced Hardware Costs – Saves specialty hard-<br />
ware costs and administration problems by eliminating<br />
cumbersome and expensive mode conditioning patch<br />
cords required for 1300-nm laser operation on tradi-<br />
tional multimode fi bers<br />
All ACCUMAX Plenum-Rated <strong>Cable</strong>s and unit tubes carry<br />
the OFNP classifi cation as described in the NEC, and<br />
are CSA certifi ed per CSA OFN FT4/FT6. These<br />
cables are also UL Listed and tested per<br />
NFPA 262.<br />
Single Tube Multi Tube<br />
ACCUMAX Plenum-Rated<br />
<strong>Cable</strong> with LaserWave Fiber<br />
Fiber Count 2 4 6 8 12 18 24 18 24 36 48 72 96 144<br />
<strong>Cable</strong> Outer Diameter – in.<br />
(mm)<br />
<strong>Cable</strong> Weight – lb/kft<br />
(kgm/km)<br />
Maximum Rated lb<br />
<strong>Cable</strong> Load (MRCL) (N)<br />
0.156<br />
(4.0)<br />
8.5<br />
(12.6)<br />
275<br />
(1223)<br />
0.177<br />
(4.5)<br />
10.8<br />
(16.2)<br />
275<br />
(1223)<br />
0.197<br />
(5.0)<br />
12.1<br />
(18.1)<br />
275<br />
(1223)<br />
0.20<br />
(5.1)<br />
17<br />
(25.6)<br />
275<br />
(1223)<br />
0.22<br />
(5.6)<br />
17.7<br />
(25.8)<br />
300<br />
(1334)<br />
0.264<br />
(6.7)<br />
29<br />
(43)<br />
150<br />
(660)<br />
0.283<br />
(7.2)<br />
37<br />
(55)<br />
400<br />
(1780)<br />
0.544<br />
(13.82)<br />
112<br />
(166)<br />
500<br />
(2224)<br />
0.544<br />
(13.82)<br />
0.65<br />
(16.5)<br />
145.4<br />
(217)<br />
0.601<br />
(15.27)<br />
0.73<br />
(18.54)<br />
Fibers Per Tube — — — — — — — 6 6 12 12 12 12 12<br />
prem-117-0609<br />
143.9<br />
(215)<br />
500<br />
(2224)<br />
500<br />
(2224)<br />
133.5<br />
(199)<br />
600<br />
(2700)<br />
139.8<br />
(208)<br />
600<br />
(2700)<br />
0.865<br />
(22)<br />
329<br />
(490)<br />
600<br />
(2700)<br />
Fibers Per Tube — — — — — — — 6 6 6 12 12 12 12<br />
ACCUMAX LS0H-Rated <strong>Cable</strong><br />
ACCUMAX LS0H-Rated <strong>Distribution</strong> <strong>Cable</strong>s are especially<br />
well suited for installation in riser shafts, above drop<br />
ceilings, under raised fl oors or in conduits. These cables<br />
contain absolutely no lead or heavy metals such as mercury,<br />
chromium or cadmium and are R0HS compliant.<br />
Note: Other elements specifi c to multitube<br />
cables not depicted here<br />
[Unit (Tube) Jacket (Flame<br />
Retardant Non-Lead) and<br />
Organizers (Flame Retardant<br />
Non-Lead)]<br />
ACCUMAX LS0H-Rated <strong>Cable</strong> – Specifications and Handling<br />
All ACCUMAX LS0H-Rated <strong>Cable</strong>s and unit tubes<br />
meet or exceed IEC 60754-2 corrosivity and<br />
NES 713 toxicity standards; IEC 60332-<br />
3C and UL 1666 fl ame test stan- standards,<br />
and IEC 61034-2 smoke<br />
emission test standards.<br />
Single Tube Multi Tube<br />
Fiber Count 2 4 6 8 12 18 24 18 24 36 48 72 96 144<br />
<strong>Cable</strong> Outer Diameter – in.<br />
(mm)<br />
<strong>Cable</strong> Weight – lb/kft<br />
(kgm/km)<br />
Maximum Rated lb<br />
<strong>Cable</strong> Load (MRCL) (N)<br />
0.156<br />
(4.0)<br />
10<br />
(14.3)<br />
275<br />
(1223)<br />
0.173<br />
(4.4)<br />
12<br />
(17.1)<br />
275<br />
(1223)<br />
0.197<br />
(5.0)<br />
15<br />
(22.5)<br />
275<br />
(1223)<br />
0.213<br />
(5.4)<br />
19<br />
(28.5)<br />
275<br />
(1223)<br />
0.238<br />
(6)<br />
21<br />
(30.8)<br />
300<br />
(1334)<br />
Outer Jacket<br />
(Low-Smoke PVC Non-Lead)<br />
900 µm Tight Buffer Fiber<br />
(Low Smoke PVC Non-Lead)<br />
Aramid Yarn Strength Members<br />
Outer Jacket<br />
(Flame Retardant Non-Lead)<br />
900 µm Tight Buffer Fiber<br />
(Nylon)<br />
Aramid Yarn Strength Members<br />
0.311<br />
(7.9)<br />
32<br />
(48)<br />
300<br />
(1334)<br />
0.339<br />
(8.6)<br />
55<br />
(82)<br />
300<br />
(1334)<br />
0.582<br />
(14.78)<br />
115<br />
(171)<br />
500<br />
(2224)<br />
0.582<br />
(14.78)<br />
112<br />
(166)<br />
500<br />
(2224)<br />
0.555<br />
(14.1)<br />
109<br />
(163)<br />
500<br />
(2224)<br />
0.803<br />
(20.4)<br />
210<br />
(313)<br />
600<br />
(2700)<br />
0.803<br />
(20.4)<br />
223<br />
(332)<br />
600<br />
(2700)<br />
0.88<br />
(22.35)<br />
355<br />
(528)<br />
600<br />
(2700)<br />
0.921<br />
(23.4)<br />
318<br />
(474)<br />
1000<br />
(4445)<br />
ACCUMAX LS0H-Rated<br />
<strong>Cable</strong> with Multimode Fiber<br />
0.94<br />
(23.87)<br />
308<br />
(458)<br />
1000<br />
(4445)