The ACCUMAX Plenum-Rated <strong>Distribution</strong> <strong>Cable</strong> offers<br />

an ideal choice for plenum applications including fi berto-the-desktop.<br />

ACCUMAX <strong>Cable</strong> featuring LaserWave ®<br />

ACCUMAX Plenum-Rated <strong>Cable</strong><br />

Multimode Fiber is specifi cally designed for:<br />

• Seamless Migration – Supports continuous migration<br />

from 10 Mbps to 10 Gbps with no cabling system<br />

changes up to 300 meters<br />

• Lower Installation Costs – Enables lowest cost<br />

for legacy through 10-GBps applications, helping to<br />

reduce total system cost by 25% or more<br />

• Improved Cabling System Administration – Saves<br />

time, using a single cable type which speeds cabling<br />

system administration<br />

Note: Other elements specifi c to multitube<br />

cables not depicted here<br />

[Unit (Tube) Jacket (PVDF) and<br />

Organizers (PVDF)]<br />

ACCUMAX Plenum-Rated <strong>Cable</strong> – Specifications and Handling<br />

• Reduced Hardware Costs – Saves specialty hard-<br />

ware costs and administration problems by eliminating<br />

cumbersome and expensive mode conditioning patch<br />

cords required for 1300-nm laser operation on tradi-<br />

tional multimode fi bers<br />

All ACCUMAX Plenum-Rated <strong>Cable</strong>s and unit tubes carry<br />

the OFNP classifi cation as described in the NEC, and<br />

are CSA certifi ed per CSA OFN FT4/FT6. These<br />

cables are also UL Listed and tested per<br />

NFPA 262.<br />

Single Tube Multi Tube<br />

ACCUMAX Plenum-Rated<br />

<strong>Cable</strong> with LaserWave Fiber<br />

Fiber Count 2 4 6 8 12 18 24 18 24 36 48 72 96 144<br />

<strong>Cable</strong> Outer Diameter – in.<br />

(mm)<br />

<strong>Cable</strong> Weight – lb/kft<br />

(kgm/km)<br />

Maximum Rated lb<br />

<strong>Cable</strong> Load (MRCL) (N)<br />

0.156<br />

(4.0)<br />

8.5<br />

(12.6)<br />

275<br />

(1223)<br />

0.177<br />

(4.5)<br />

10.8<br />

(16.2)<br />

275<br />

(1223)<br />

0.197<br />

(5.0)<br />

12.1<br />

(18.1)<br />

275<br />

(1223)<br />

0.20<br />

(5.1)<br />

17<br />

(25.6)<br />

275<br />

(1223)<br />

0.22<br />

(5.6)<br />

17.7<br />

(25.8)<br />

300<br />

(1334)<br />

0.264<br />

(6.7)<br />

29<br />

(43)<br />

150<br />

(660)<br />

0.283<br />

(7.2)<br />

37<br />

(55)<br />

400<br />

(1780)<br />

0.544<br />

(13.82)<br />

112<br />

(166)<br />

500<br />

(2224)<br />

0.544<br />

(13.82)<br />

0.65<br />

(16.5)<br />

145.4<br />

(217)<br />

0.601<br />

(15.27)<br />

0.73<br />

(18.54)<br />

Fibers Per Tube — — — — — — — 6 6 12 12 12 12 12<br />

prem-117-0609<br />

143.9<br />

(215)<br />

500<br />

(2224)<br />

500<br />

(2224)<br />

133.5<br />

(199)<br />

600<br />

(2700)<br />

139.8<br />

(208)<br />

600<br />

(2700)<br />

0.865<br />

(22)<br />

329<br />

(490)<br />

600<br />

(2700)<br />

Fibers Per Tube — — — — — — — 6 6 6 12 12 12 12<br />

ACCUMAX LS0H-Rated <strong>Cable</strong><br />

ACCUMAX LS0H-Rated <strong>Distribution</strong> <strong>Cable</strong>s are especially<br />

well suited for installation in riser shafts, above drop<br />

ceilings, under raised fl oors or in conduits. These cables<br />

contain absolutely no lead or heavy metals such as mercury,<br />

chromium or cadmium and are R0HS compliant.<br />

Note: Other elements specifi c to multitube<br />

cables not depicted here<br />

[Unit (Tube) Jacket (Flame<br />

Retardant Non-Lead) and<br />

Organizers (Flame Retardant<br />

Non-Lead)]<br />

ACCUMAX LS0H-Rated <strong>Cable</strong> – Specifications and Handling<br />

All ACCUMAX LS0H-Rated <strong>Cable</strong>s and unit tubes<br />

meet or exceed IEC 60754-2 corrosivity and<br />

NES 713 toxicity standards; IEC 60332-<br />

3C and UL 1666 fl ame test stan- standards,<br />

and IEC 61034-2 smoke<br />

emission test standards.<br />

Single Tube Multi Tube<br />

Fiber Count 2 4 6 8 12 18 24 18 24 36 48 72 96 144<br />

<strong>Cable</strong> Outer Diameter – in.<br />

(mm)<br />

<strong>Cable</strong> Weight – lb/kft<br />

(kgm/km)<br />

Maximum Rated lb<br />

<strong>Cable</strong> Load (MRCL) (N)<br />

0.156<br />

(4.0)<br />

10<br />

(14.3)<br />

275<br />

(1223)<br />

0.173<br />

(4.4)<br />

12<br />

(17.1)<br />

275<br />

(1223)<br />

0.197<br />

(5.0)<br />

15<br />

(22.5)<br />

275<br />

(1223)<br />

0.213<br />

(5.4)<br />

19<br />

(28.5)<br />

275<br />

(1223)<br />

0.238<br />

(6)<br />

21<br />

(30.8)<br />

300<br />

(1334)<br />

Outer Jacket<br />

(Low-Smoke PVC Non-Lead)<br />

900 µm Tight Buffer Fiber<br />

(Low Smoke PVC Non-Lead)<br />

Aramid Yarn Strength Members<br />

Outer Jacket<br />

(Flame Retardant Non-Lead)<br />

900 µm Tight Buffer Fiber<br />

(Nylon)<br />

Aramid Yarn Strength Members<br />

0.311<br />

(7.9)<br />

32<br />

(48)<br />

300<br />

(1334)<br />

0.339<br />

(8.6)<br />

55<br />

(82)<br />

300<br />

(1334)<br />

0.582<br />

(14.78)<br />

115<br />

(171)<br />

500<br />

(2224)<br />

0.582<br />

(14.78)<br />

112<br />

(166)<br />

500<br />

(2224)<br />

0.555<br />

(14.1)<br />

109<br />

(163)<br />

500<br />

(2224)<br />

0.803<br />

(20.4)<br />

210<br />

(313)<br />

600<br />

(2700)<br />

0.803<br />

(20.4)<br />

223<br />

(332)<br />

600<br />

(2700)<br />

0.88<br />

(22.35)<br />

355<br />

(528)<br />

600<br />

(2700)<br />

0.921<br />

(23.4)<br />

318<br />

(474)<br />

1000<br />

(4445)<br />

ACCUMAX LS0H-Rated<br />

<strong>Cable</strong> with Multimode Fiber<br />

0.94<br />

(23.87)<br />

308<br />

(458)<br />

1000<br />

(4445)