ALARM CONTROL PANELS<br />

SITE ALARMS &<br />

DETECTION SYSTEMS<br />

CFP Fire Alarm Control Panels<br />

Product Code:<br />

ALARM PANEL CFP702-4<br />

ALARM PANEL CFP704-4<br />

ALARM PANEL CFP708-4<br />

ALARM PANEL CFP760<br />

• Complies fully with EN54: Parts 2 & 4<br />

• Attractive flush or surface mountable plastic lid and enclosure<br />

• Four conventional sounder circuits<br />

• Class change and alert inputs<br />

• Auxiliary fault, reset, remote and auxiliary fire outputs<br />

• Wide range of engineering functions including zone<br />

test, non-latching zones, programmable delays and coincidence<br />

• Code entry version available as standard, keyswitch models available on request<br />

• Ancillary connections for up to eight two-wire repeaters<br />

per system and optional CFP relay boards.<br />

Code No of Zones No. of batteries Dimensions<br />

CFP702-4 2 2 x 12v, 2.1 Ah H235 x W380 x D96<br />

CFP704-4 4 2 x 12v, 2.1 Ah H235 x W380 x D96<br />

CFP708-4 8 2 x 12v, 2.1 Ah H235 x W380 x D96<br />

CFP760 8 zone rpt 2 x 12v, 2.1 Ah H235 x W380 x D96<br />

CFP Alarm Panel Accessories<br />

Product Code:<br />

ALARM CARD CFP761<br />

ALARM CARD CFP762<br />

ALARM CARD CFP763<br />

Code Description<br />

CFP761 CFP network driver card, one required per repeater system, fit at mains<br />

CFP762 CFP relay output card, provides reset, fault, aux and remote relay outputs<br />

CFP763 CFP relay output per zone card, as CPF 762 plus 8 outputs per zone relays<br />

FP585 Fire Alarm Control Panels<br />

Product Code:<br />

ALARM PANEL FP585/01 ALARM PANEL FP585/02<br />

ALARM PANEL FP585/04 ALARM PANEL FP585/08<br />

ALARM PANEL FP585/R<br />

• Complies fully with EN54: parts 2 & 4<br />

• Can be used on installations meeting BS5839: Part 1<br />

• Panels available with up to eight alarm sounder circuits<br />

• Zone disablement facility<br />

• One man test and commission facility<br />

• Two auxiliary relay contacts<br />

• LPCB approved<br />

• Battery support facility (batteries supplied separately)<br />

Code No of Zones No. of batteries Dimensions<br />

FP585/01 1 2 x 12v, 2.1 Ah H274 x W395 x D87<br />

FP585/02 2 2 x 12v, 2.1 Ah H274 x W395 x D87<br />

FP585/04 4 2 x 12v, 2.1 Ah H274 x W395 x D87<br />

FP585/08 8 2 x 12v, 2.8 Ah H274 x W395 x D87<br />

FP585/R 8 zone repeat 2 x 12v, 2.1 Ah H274 x W395 x D87<br />

FP585/08<br />

CFP702-4<br />

Did you<br />

know?...<br />

The<br />

Regulatory Reform<br />

(Fire Safety) Order<br />

requires that, where<br />

necessary, premises<br />

must, to the extent<br />

appropriate, be<br />

equipped with<br />

appropriate fire<br />

detectors and<br />

alarms. Automatic<br />

fire detection will be<br />

needed in certain<br />

circumstances, such<br />

as premises where<br />

people sleep, where<br />

needed to operate