Prevailing wind directi<strong>on</strong> (see paragraphs 56 <strong>and</strong> 57)<br />
Minimum<br />
distance<br />
(metres)<br />
B<br />
C<br />
D<br />
E<br />
D A D<br />
Fall-out area<br />
(Dropping z<strong>on</strong>e)<br />
Firing area<br />
<strong>Safety</strong> area<br />
Spectator area<br />
A B C D E<br />
50<br />
approx.<br />
100* 25 50* As required,<br />
to prevent<br />
overcowding<br />
* The distances in columns B <strong>and</strong> D may have to be modified for certain<br />
types <strong>and</strong> sizes of <strong>firework</strong><br />
B<strong>on</strong>fire area<br />
Locate this anywhere, provided it is:<br />
n at least 15 m from other areas, buildings, roads, railways <strong>and</strong> public<br />
rights of way;<br />
n a safe distance from flammable or otherwise dangerous materials (eg<br />
petrol, fuel oil, liquefied petroleum gas) <strong>and</strong> overhead electric power<br />
lines; <strong>and</strong><br />
n downwind of spectators.<br />
Figure 1 Site layout for <strong>displays</strong> (see paragraphs 16-23)<br />