SPRINKLER IDENTIFICATION SIGNS CONT.<br />

13-A 12”x 10” ALUMINUM SPRINKLER ID SIGNS<br />

AUTOMATIC<br />

SPRINKLER<br />

IN<br />

GARAGE ONLY<br />

SIAMESE<br />

CONNECTION<br />

FOR FIRE DEPT.<br />

AUTOMATIC<br />

SPRINKLER<br />

IN<br />

BASEMENT ONLY<br />

SPRINKLER<br />

CONTROL<br />

VALVE<br />

AUTOMATIC SPRINKLER<br />

SHUT-OFF VALVE<br />

LOCATED______FT.<br />

OPPOSITE THIS SIGN<br />

50-10-046 50-10-047 50-10-048 50-10-060<br />

50-10-315 50-10-323<br />

50-10-331 50-10-333<br />

50-10-345 50-10-360<br />

IDENTIFICATION SIGNS • SERVICE DECALS • INSPECTION TAGS<br />

13-B INSPECTION TAGS & DECALS<br />

All tags and decals available Generic or<br />

Personally customized with your company’s<br />

name, logo, address and phone<br />

•White Vinyl Decals with Bright Red Copy<br />

•Card stock with choice of<br />

paper color and ink color<br />

Florida Tag<br />

(50-41-275)<br />

DO NOT REMOVE<br />

BY ORDER OF<br />

THE STATE FIRE MARSHAL<br />

6-1/4" x 3-1/4"<br />

Sprinkler System<br />

Standpipe & Hose<br />

Fire Main<br />

Fire Pump<br />

WORK PERFORMED BY:<br />

NAME: (print)________________________________<br />

SIGNATURE_________________________________<br />

DATE__________<br />

SYSTEM<br />

INSPECTOR LISTING#________________________ NEW<br />

QUARTERLY<br />

SEMI-ANNUAL<br />

ANNUAL<br />

Storage Tanks<br />

Spray System<br />

Foam/Water System<br />

Valves & Fire<br />

Dept. Connection<br />

3 YEAR<br />

5 YEAR<br />

INSPECTION<br />

TEST &<br />

MAINTENANCE<br />

REPAIR<br />

ADDITION<br />

5 Yr. Tag<br />

(50-40-270)<br />

For more information see the inspection report<br />

INSPECTION TAG<br />

DO NOT REMOVE<br />

BY ORDER OF<br />

THE STATE FIRE MARSHAL<br />

_______________________<br />

Signature<br />

Two sizes:<br />

5-1/2" x 2-5/8"<br />

and<br />

6-1/4" x 3-1/8"<br />

Quarterly<br />

Tag<br />

(50-40-271)<br />

INSPECTION TAG<br />

800-854-1015 www.argco.com FAX 760-727-3270<br />

13<br />

WET SYSTEM<br />

DRY SYSTEM<br />

VALVE SERIAL NO.<br />

STATIC WATER PSI<br />

RESIDUAL WATER PSI<br />

DO ALARMS OPERATE<br />

AIR PRESSURE<br />

AIR PRESSURE TIME<br />

TRIP TIME (SEC)<br />

WATER FLOW TIME (SEC)<br />

LOW POINTS DRAINED<br />

WATER SUPPLY OPEN<br />

ANTIFREEZE TEMP. RATING<br />

DELUGE VALVE<br />

ANTI-FREEZE<br />

PRE-ACTION VALVE<br />

1st 2nd 3rd 4th<br />

NUMBER OF LOW POINTS TO BE DRAINED<br />

INSPECTION MADE AND WITNESSED BY<br />

DATE & INSP. # MADE BY WITNESSED BY<br />

DO NOT REMOVE<br />

YEARLY and MONTHLY<br />

INSPECTION TAG<br />

________________does not assume any<br />

responsibility for failure to operate as such<br />

failures may be due to causes beyond our<br />

control such as malicious tampering accidents,<br />

failure to perform required modificationsinadequate<br />

heat for wet systems,<br />

etc.<br />

The <strong>sprinkler</strong> system has been placed<br />

back into service with the control valves<br />

inoperational condition by____________<br />

and hence forth the owner is responsible<br />

for further "care and maintenance"<br />

described in NFPA 13A and NFPA 25"<br />

7-3/4" x 3-3/4" back side