Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
sunedison delta rack<br />
non-penetrating flatroof Mounting systeM<br />
Delta rack DiagraMs<br />
fIll c-channEl W/<br />
SolID concRETE blockS<br />
c-channEl aTTachED<br />
To folDER Rack fRamE<br />
(onE moDulE Span)<br />
STanDaRD bRIckS To<br />
holD c-channEl In placE<br />
ParaMeters & sPecifications<br />
Length<br />
Width<br />
Height<br />
Weight<br />
Materials<br />
Life Expectancy<br />
Wind<br />
Snow<br />
Region<br />
Rooftop<br />
* Note that product specifications are subject to change.<br />
© 2011 MEMC Electronic Materials Inc. All rights reserved. MEMC, SunEdison, the MEMC logo, the SunEdison Logo and the Joint MEMC SunEdison logo are registered trademarks<br />
or trademarks of MEMC Electronic Materials, Inc. and/or its affiliates in the United States and certain other countries. All other trademarks mentioned in this document are<br />
the property of their respective owners. The use of the word partner does not imply a partnership relationship between MEMC Electronic Materials Inc. and any other company.<br />
Printed on recycled paper<br />
DEflEcToR SpanS EnTIRE<br />
hEIGhT of moDulE anD<br />
WRapS ovER moDulE fRamE<br />
RIvETS aTTach ballaST<br />
TRay connEcToR To fRamE<br />
bRacE channEl connEcTS To<br />
DEflEcToR ThRouGh RIvETS<br />
5ft., 11in.<br />
3ft.<br />
11in.<br />
InTRaRoW<br />
connEcToR<br />
14lbs.<br />
Galvalume Steel<br />
20+ Years<br />
moDulE<br />
bolT aSSEmbly aTTachES<br />
STRuT To fRamE<br />
Tested for 100mph wind<br />
Snow load of 30 psf<br />
Appropriate for low seismic activity regions<br />
Suitable for flat rooftops with a minimum of 5 psf<br />
of dead load available<br />
for More inforMation<br />
To learn more about how the Delta Rack can help you unlock<br />
energy savings, contact SunEdison at 12500 Baltimore Avenue,<br />
Beltsville, MD 20705, or call 866-<strong>SUNEDISON</strong> (1-866-786-3347),<br />
or visit us on the Web at www.sunedison.com.<br />
ballaST<br />
TRay<br />
aDDITIonal ballaST unITS<br />
placED aT noRTh SIDE of<br />
moDulE<br />
SolaR moDulE<br />
aDDITIonal ballaST TRay<br />
bRIckS In ThE REaR<br />
of EvERy boTTom<br />
channEl<br />
WEaR paD RIvET<br />
pREaTTachED<br />
InTRaRoW To fRamE<br />
Gaf WEaR paD To pRoTEcT<br />
mEmbRanE SuRfacE<br />
Delta rack iMPleMentations<br />
concRETE oR clay<br />
bRIckS Each RoW EnD<br />
SunEdison Delta Rack Non-Penetrating Flatroof Mounting System Data Sheet<br />
®<br />
An Company<br />
InTRaRoW<br />
connEcToR<br />
RoofInG WEaR<br />
paDS aT fRonT<br />
anD REaR unDER<br />
Each fRamE