The resistance of 20 gauge wire is 0.012 Ω/ft, so if the cables are 20 gauge, and 1 foot in<br />
length, that adds another 0.024 Ω, in addition to the contact resistance.<br />
Figure 10: Vout LED indicator<br />
If the power-up is successful, the green Vout LED indicator in Figure 10 above will powerup.<br />
This LED is connected directly to Vout, so the light will dim slightly if the voltage is<br />
lowered. If this LED does not power-up, then Vout did not power-up properly, so there are<br />
other problems.<br />
Over-Current Error from the Main <strong>Power</strong> Supply<br />
Sometimes an over-current error occurs when powering-up. When an over-current error<br />
occurs, the amber LED powers-up, and the green LED for Vout powers-down.<br />
An over-current error can happen when the:<br />
• <strong>Device</strong> is attached backwards.<br />
• <strong>Device</strong> is attached incorrectly.<br />
• <strong>Device</strong> has a lot of capacitance, a very high in-rush current.<br />
• <strong>Device</strong> has an unusually high run current.