Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Columns</strong> <strong>and</strong> <strong>Supplies</strong><br />
<strong>for</strong> <strong>HPLC</strong>
2<br />
Your link to success
<strong>HPLC</strong> columns <strong>and</strong> supplies<br />
Your link to success . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4<br />
Cartridge/Guard Cartridge system selection guide . . . . . . . . . . .6<br />
Cartridge column systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7<br />
Reversed phase <strong>HPLC</strong> columns . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br />
Microbore <strong>and</strong> capillary columns . . . . . . . . . . . . . . . . . . . . . . . .18<br />
Normal phase <strong>and</strong> chiral <strong>Columns</strong> . . . . . . . . . . . . . . . . . . . . . . . .24<br />
Gel permeation chromatography columns . . . . . . . . . . . . . . . . . .26<br />
Reversed phase <strong>HPLC</strong> columns <strong>for</strong> bio science . . . . . . . . . . . . .28<br />
<strong>HPLC</strong> columns <strong>for</strong> biomolecules . . . . . . . . . . . . . . . . . . . . . . . . . .30<br />
Special application columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33<br />
<strong>HPLC</strong> column kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34<br />
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36<br />
Vials <strong>and</strong> caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38<br />
Crimpers <strong>and</strong> decappers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40<br />
Filters <strong>and</strong> degassers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42<br />
<strong>Supplies</strong> <strong>for</strong> Agilent 1100 Series . . . . . . . . . . . . . . . . . . . . . . . . .44<br />
<strong>Supplies</strong> <strong>for</strong> Agilent 1050 Series . . . . . . . . . . . . . . . . . . . . . . . . .50<br />
<strong>Supplies</strong> <strong>for</strong> Agilent 1090 Series . . . . . . . . . . . . . . . . . . . . . . . . .52<br />
Application literature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54<br />
Basic <strong>HPLC</strong> troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60<br />
3
4<br />
Your link to success<br />
The analytical quality built into<br />
Agilent Technologies liquid<br />
chromatographs means success<br />
<strong>for</strong> complex separation work. But<br />
Agilent Technologies doesn’t stop<br />
with the instruments: quality is<br />
incorporated into everything<br />
needed to keep them in prime<br />
condition. Rigorous quality control<br />
<strong>and</strong> continuous improvement<br />
programs allow Agilent<br />
Technologies to offer a full range<br />
of supplies designed to last<br />
longer. This not only helps to<br />
lower operation costs, but also<br />
increases productivity by avoiding<br />
periods of downtime <strong>and</strong><br />
recurrent interruptions <strong>for</strong><br />
maintenance.<br />
Agilent Technologies<br />
manufactures ZORBAX-br<strong>and</strong><br />
<strong>HPLC</strong> columns. Agilent also packs<br />
a selection of other high-quality<br />
materials such as Hypersil,<br />
Asahipak, LiChrosorb, <strong>and</strong><br />
Nucleosil.<br />
The combination of these highquality<br />
packing materials with<br />
high-quality column hardware of<br />
different types (st<strong>and</strong>ard fitting<br />
columns <strong>and</strong> different cartridge<br />
column systems) is the ideal<br />
solution to all the different needs<br />
in your lab.<br />
In addition Agilent offers a<br />
selection of high-quality columns<br />
<strong>for</strong> special applications such as<br />
ion exchange columns <strong>and</strong><br />
columns <strong>for</strong> biomolecular<br />
separations.<br />
Agilent Technologies’ <strong>HPLC</strong><br />
columns are manufactured to<br />
exacting st<strong>and</strong>ards <strong>and</strong><br />
stringently tested be<strong>for</strong>e ever<br />
leaving the factory.<br />
Detailed test documentation<br />
is shipped with the separation<br />
columns to help you to meet your<br />
GLP/BMP/ISO requirements <strong>and</strong><br />
<strong>for</strong> your in<strong>for</strong>mation about the<br />
continous quality of Agilent’s<br />
products.<br />
The consistent quality adds value<br />
to Agilent Technologies liquid<br />
chromatographs, not only by<br />
improving analyses, but also by<br />
integrating <strong>and</strong> complementing<br />
the total system. In addition, run-<br />
to-run reproducibility is ensured<br />
with the winning combination of<br />
Agilent’s liquid chromatographs,<br />
columns, <strong>and</strong> supplies.<br />
With such quality, consistency,<br />
<strong>and</strong> reliability, the choice is<br />
simple – Agilent!<br />
Browse through this brochure<br />
<strong>and</strong> call your local Agilent<br />
Technologies analytical sales<br />
office, or your authorized Agilent<br />
distributor to place your order.<br />
For our full range of supplies look<br />
at our main catalog or visit us on<br />
the web at:<br />
www.agilent.com/chem
Free of charge<br />
application primer:<br />
Good Laboratory Practice <strong>and</strong><br />
Current Good Manufacturing<br />
Practice<br />
Publication number: 5968-6193E<br />
For<br />
analytical<br />
laboratories<br />
A primer<br />
Good laboratory practice<br />
<strong>and</strong> current good<br />
manufacturing practice<br />
From the bookshelf:<br />
Practical <strong>HPLC</strong> Method<br />
Development,<br />
2nd edition by L. R. Snyder, J. J.<br />
Kirkl<strong>and</strong>, <strong>and</strong><br />
Joseph Glajch<br />
(John Wiley & Sons, 1997)<br />
Part number: 5183-2005<br />
Practical <strong>HPLC</strong> Methodology<br />
<strong>and</strong> Applications<br />
by Brian A. Bidlingmeyer<br />
(John Wiley & Sons, 1993)<br />
Part number: 5183-2006<br />
Validation of Computerized<br />
Analytical Systems<br />
by L. Huber<br />
(Interpharm, 1995)<br />
Part number: 5959-3879<br />
Validation <strong>and</strong> Qualification in<br />
Analytical Laboratories<br />
by L. Huber<br />
(Interpharm, 1998)<br />
Part number: 5965-0036<br />
5
6<br />
Cartridge/Guard cartridge systems compatibility guide<br />
Guard cartridge internal diameter<br />
Column type holder (mm) Phases Icon<br />
cartridge column guard cartridge (integral system) 2.0 Asahipak<br />
3.0 Hypersil<br />
cartridge holder cartridge holder 4.0 Lichrospher<br />
5021-1845 5021-1845 4.6 Nucleosil<br />
Purospher<br />
Superspher<br />
Zorbax<br />
st<strong>and</strong>ard fitting column guard cartridge (st<strong>and</strong>-alone)* 2.1 Hypersil<br />
4.6 Lichrosorb<br />
cartridge holder<br />
79900CH-010<br />
st<strong>and</strong>ard fitting column guard cartridge (st<strong>and</strong>-alone)* 2.1 Zorbax<br />
3.0<br />
cartridge holder 4.6<br />
820777-901<br />
Rapid Resolution no guard cartridge required 2.1 Zorbax<br />
cartridge column (st<strong>and</strong>-alone) 4.6<br />
cartridge holder<br />
820222-901<br />
semi prep. column semi prep. guard cartridge 9.4 Zorbax<br />
(st<strong>and</strong>-alone)*<br />
cartridge holder 840140-901<br />
* St<strong>and</strong>-alone guard cartridges fit to all cartridge <strong>and</strong><br />
st<strong>and</strong>ard fitting columns available from Agilent.<br />
All columns without<br />
icons are st<strong>and</strong>ard<br />
fitting columns.
Agilent Technologies cartridge column system<br />
Agilent offers a variety of popular <strong>HPLC</strong> packing materials<br />
in economical, easy to use cartridge configurations.<br />
Agilent cartridge configuration<br />
Agilent’s flexible cartridge system<br />
has been thoroughly tested to<br />
ensure that the design <strong>and</strong><br />
hardware meet Agilent’s<br />
st<strong>and</strong>ards of quality. Finger-tight<br />
connections allow rapid column<br />
changes without removing the<br />
capillaries from the end fittings.<br />
The same convenient, easy-touse<br />
cartridge holder accommodates<br />
2, 3, 4 <strong>and</strong> 4.6 mm diameter<br />
cartridges of varying lengths. The<br />
cartridge columns have a unique<br />
filter <strong>and</strong> sieve at each end that<br />
help prevent blockage.<br />
Agilent Cartridge System Accessories<br />
By reversing the collets in the<br />
end fitting, an inexpensive guard<br />
cartridge can be added to further<br />
extend column lifetime.<br />
Description Part No.<br />
Cartridge holder <strong>for</strong> 2, 3, 4 <strong>and</strong> 4.6 mm id cartridges 5021-1845<br />
Replacement filters 4 <strong>and</strong> 4.6 mm id cartridges, pack of 10 5063-6574<br />
Replacement filter 2 <strong>and</strong> 3 mm id cartridges, pack of 10 5063-6519<br />
Mounting tool <strong>for</strong> replacement filters 5021-1846<br />
Look <strong>for</strong> this icon<br />
identifying Agilent<br />
cartridge columns in<br />
column ordering tables.<br />
7
8<br />
Agilent‘s reusable guard cartridge<br />
holder provides <strong>for</strong> rapid<br />
exchange of inexpensive guard<br />
columns, which are used to<br />
protect valuable columns from<br />
damaging samples.<br />
This st<strong>and</strong>-alone system is<br />
suitable <strong>for</strong> both 2.1 <strong>and</strong> 4.0 mm<br />
id. guard cartridge columns. It<br />
can be connected by capillaries<br />
to different st<strong>and</strong>ard fitting <strong>and</strong><br />
cartridge columns.<br />
To ensure leak-free <strong>and</strong> minimum<br />
dead-volume connections, Agilent<br />
recommends using ¼ inch<br />
wrenches <strong>for</strong> installation.<br />
The guard cartridge system is<br />
rigidly tested to meet Agilent‘s<br />
high-quality specifications,<br />
making it a perfect fit with your<br />
<strong>HPLC</strong> instrumentation.<br />
Guard cartridge system <strong>for</strong> fitting type columns<br />
The guard cartridge system is not<br />
compatible with PEEK fittings.<br />
Guard Cartridge System Accesories<br />
This icon identifies st<strong>and</strong>-alone<br />
guard cartridge systems <strong>for</strong><br />
analytical columns.<br />
Description Part No.<br />
Guard cartridge holder (<strong>for</strong> 2.1 <strong>and</strong> 4 mm id) 79900CH-010<br />
Connecting capillary 35 x 0.12 mm 79841-87609<br />
4.0 mm id frits <strong>and</strong> caps <strong>for</strong> guard column (6/pk) 01090-27613<br />
4.0 mm SS inserts (6/pk) 01090-27614<br />
2.1 mm id frits <strong>and</strong> caps <strong>for</strong> guard column (6/pk) 01090-27606<br />
2.1 mm SS inserts (6/pk) 01090-27611
Zorbax guard cartridge<br />
The ZORBAX Cartridge Guard-<br />
Column Series has been<br />
developed to provide convenient,<br />
cost-effective protection <strong>for</strong> high<br />
per<strong>for</strong>mance analytical columns.<br />
The cartridge components<br />
assemble quickly to provide a<br />
high-efficiency, low-dead-volume<br />
column that seals at high<br />
pressures (up to 3000 psi).<br />
The polymeric guard column<br />
tubing is specifically designed to<br />
make leak-tight seals against<br />
metal surfaces without requiring<br />
gaskets.<br />
ZORBAX guard cartridge system accessories<br />
This polymeric tube material<br />
(polyphenylenesulfone) is also<br />
more solvent-resistant than PEEK.<br />
The reusable guard column end<br />
fittings adapt the guard cartridge<br />
column <strong>for</strong> connection to 1/16 inch<br />
LC fittings <strong>and</strong> provide a st<strong>and</strong>alone<br />
guard column system <strong>for</strong><br />
2.1 <strong>and</strong> 4.6 mm i.d. columns.<br />
Description Part No.<br />
Guard fittings kit including: 820777-901<br />
guard column holder (1), guard end fitting (1),<br />
<strong>and</strong> column connector (1)<br />
Guard end fitting 820572-001<br />
Guard cartridge holder 820565-001<br />
Column connector 820563-901<br />
This icon identifies st<strong>and</strong>alone<br />
guard cartridges <strong>for</strong><br />
ZORBAX analytical columns.<br />
9
10<br />
Rapid Resolution cartridge column system<br />
For fast, clean high throughput<br />
LC/MS, LC/MS/MS <strong>and</strong><br />
combinatorial separations, we<br />
recommend the new ZORBAX<br />
Rapid Resolution Cartridge<br />
<strong>Columns</strong>. These cartridges are<br />
packed with ZORBAX StableBond<br />
<strong>and</strong> Eclipse bonded phases that<br />
provide excellent separations<br />
without contaminations from<br />
bonded phase degradation.<br />
Cartridge dimensions are<br />
4.6 x 15 mm or 4.6 x 30 mm <strong>and</strong><br />
narrow bore sizes 2.1 x 15 mm or<br />
2.1 x 30 mm, all with high purity<br />
(99.995%) 3.5 µm ZORBAX Rx-SILbased<br />
bonded phase particles.<br />
Choose the ZORBAX StableBond<br />
SB-C18 <strong>and</strong> SB-C8 columns <strong>for</strong><br />
maximum lifetime <strong>and</strong> exceptional<br />
per<strong>for</strong>mance at low pH (<strong>for</strong>mic<br />
acid <strong>and</strong> TFA). Use Eclipse<br />
XDB-C8 <strong>and</strong> XDB-C18 when<br />
Rapid Resolution Cartridge System Accessories<br />
mid-pH conditions are required.<br />
Upon special request additional<br />
packing material can be packed.<br />
These economical <strong>and</strong> easyto-use<br />
cartridge columns are<br />
offered individually <strong>and</strong> as a<br />
convenient three-pack.<br />
Description Part No.<br />
Guard fittings kit including:<br />
cartridge holder 15 mm (1), cartridge holder 30 mm (1),<br />
end fitting assemblies (2)<br />
820222-901<br />
Cartridge holder 15 mm 820315-015<br />
30 mm 820330-030<br />
Replacement sealing gaskets (2/pk) 820370-901<br />
End fitting assembly 820311-001<br />
Rapid Resolution Cartridge<br />
<strong>Columns</strong> are marked with<br />
this icon.
Zorbax preparative guard-column hardware kit<br />
The ZORBAX Preparative Guard-<br />
Column has been developed to<br />
provide convenient, cost-effective<br />
protection <strong>for</strong> high-per<strong>for</strong>mance<br />
lab-scale preparative columns.<br />
The cartridge components<br />
assemble quickly <strong>and</strong> easily to<br />
provide a high-efficiency, lowdead-volume<br />
column that seals at<br />
pressures up to 2000 psi (135 bar,<br />
13.5 MPa).<br />
The guard-column tubing made<br />
from polyphenylene-sulfone is<br />
specifically engineered to make<br />
leak-tight seals against metal<br />
surfaces, without requiring<br />
gaskets. The reusable guardcolumn<br />
end fittings adapt the<br />
ZORBAX Preparative Guard Column Hardware<br />
cartridge guard-column <strong>for</strong><br />
connection to st<strong>and</strong>ard 1/16 inch<br />
LC fittings <strong>and</strong> provide a st<strong>and</strong>alone<br />
guard-column system. The<br />
ZORBAX materials used in<br />
preparative cartridges are<br />
matched with chemistry chosen<br />
<strong>for</strong> compatibility with a wide<br />
range of applications.<br />
Description Part No.<br />
Preparative* guard-column hardware kit including:<br />
inlet fitting, end fitting, column connector 840140-901<br />
* The preparative guard-column hardware is available only as a kit.<br />
This icon identifies<br />
preparative guardcolumns.<br />
11
12<br />
Reversed phase columns<br />
ZORBAX StableBond Reversed phase <strong>HPLC</strong> columns (80 Å)<br />
Inner diameter Length Particle size SB-C18 SB-C8 SB-C3 SB-CN SB-Phenyl<br />
[mm] [mm] [µm] USP (L1) USP (L7) USP (L10) USP (L11)<br />
0.3 150 3.5 5064-8261<br />
0.3 150 5 5064-8255<br />
0.3 250 5 5064-8257<br />
0.5 35 3.5 5064-8260<br />
0.5 150 3.5 5064-8262<br />
0.5 150 5 5064-8256<br />
0.5 250 5 5064-8258<br />
1.0 30 3.5 861600-902 861600-906<br />
1.0 50 3.5 865600-902 865600-906<br />
1.0 150 3.5 863600-902 863600-906<br />
2.1 15 3.5 875700-902 875700-906<br />
2.1 15 3.5 875700-932 1 875700-936 1<br />
2.1 30 3.5 873700-902 873700-906<br />
2.1 30 3.5 873700-932 1 873700-936 1<br />
2.1 50 3.5 871700-902 871700-906<br />
2.1 150 3.5 830990-902 830990-906<br />
2.1 50 5 860975-902 860975-906 860975-909 860975-905 860975-912<br />
2.1 150 5 883700-922 883700-906 883700-909 883700-905 883700-912<br />
3.0 150 3.5 863954-302 863954-306 863954-305 863954-312<br />
3.0 150 5 883975-302 883975-306 883975-309 883975-305 883975-312<br />
3.0 250 5 880975-302 880975-306 880975-309 880975-305 880975-312<br />
4.6 15 3.5 831975-902 831975-906<br />
4.6 15 3.5 831975-932 1 831975-936 1<br />
4.6 30 3.5 833975-902 833975-906<br />
4.6 30 3.5 833975-932 1 833975-936 1<br />
4.6 50 3.5 835975-902 835975-906 835975-905 835975-912<br />
4.6 75 3.5 866953-902 866953-906 866953-905 866953-912<br />
4.6 75 3.5 7995218-344 7995208-344<br />
4.6 150 3.5 863953-902 863953-906 863953-905 863953-912<br />
4.6 50 5 846975-902 846975-906<br />
4.6 150 5 883975-902 883975-906 883975-909 883975-905 883975-912<br />
4.6 150 5 7995218-595 7995208-595<br />
4.6 250 5 880975-902 880975-906 880975-909 880975-905 880975-912<br />
4.6 250 5 7995218-585 7995208-585<br />
9.4 250 5 880975-202 880967-201 880975-209 880975-205 880975-212<br />
21.2<br />
1 Pack of 3<br />
250 7 880975-102 880967-106 880975-105 880975-112<br />
For 300 Å StableBond columns see biotechnology section. Please inquire <strong>for</strong> a special products quote <strong>for</strong> column configurations not listed
ZORBAX StableBond guard cardridges 1<br />
(80 Å)<br />
Inner diameter Length Particle size SB-C18 SB-C8 SB-C3 SB-CN SB-Phenyl<br />
[mm] [mm] [µm] USP (L1) USP (L7) USP (L10) USP (L11)<br />
0.3 35 5 5064-8253<br />
0.5 35 5 5064-8254<br />
2.1 12.5 5 821125-926 2 821125-926 2 821125-924 3 821125-924 3 821125-926 2<br />
4.6 12.5 5 820950-920 820950-915 820950-922 820950-916 820950-917<br />
9.4 15 7 820675-1154,5 820675-1154,5 820675-1243 820675-1243,5 820675-1154,5 1 Analytical guard cartridges are pack of 4; preparative guard cartridges are pack of 2. 2 Guard cartridge pn 821125-926 is packed with Eclipse XDB-C8 <strong>and</strong><br />
recommended where listed. 3 Guard cartridge pn 821125-924 <strong>and</strong> pn 820675-124 are packed with 300SB-C3 <strong>and</strong> recommended where listed. 4 Guard cartridge<br />
pn 820675-115 is packed with SB-C8 <strong>and</strong> recommended where listed. 5 Reusable cartridge hardware <strong>for</strong> preparative columns: pn 840140-901.<br />
ZORBAX SB-Aq columns<br />
Inner diameter Length Particle size Guard column<br />
[mm] [mm] [µm] Part no. 12.5 mm long<br />
2.1 50 5 860975-914 821125-933<br />
4.6 50 5 846975-914 820950-933<br />
4.6 150 5 883975-914<br />
4.6 250 5 880975-914<br />
ZORBAX Eclipse XDB reversed phase <strong>HPLC</strong> columns (80 Å)<br />
Inner diameter Length Particle size XDB-C18 XDB-C8 XDB-Phenyl<br />
[mm] [mm] [µm] USP (L1) USP (L7) USP (L11)<br />
0.3 150 3.5 5064-8271<br />
0.3 150 5 5064-8291<br />
0.3 250 5 5064-8269<br />
0.5 35 3.5 5064-8298<br />
0.5 150 3.5 5064-8288<br />
0.5 150 5 5064-8287<br />
0.5 250 5 5064-8286<br />
2.1 15 3.5 975700-902 975700-906<br />
2.1 15 3.5 975700-932 1 975700-936 1<br />
2.1 30 3.5 973700-902 973700-906<br />
2.1 30 3.5 973700-932 1 973700-936 1<br />
1 Pack of 3 ➜<br />
13
14<br />
Inner diameter Length Particle size XDB-C18 XDB-C8 XDB-Phenyl<br />
(mm) (mm) (µm) USP (L1) USP (L7) USP (L11)<br />
1 Pack of 3<br />
Reversed phase columns<br />
➜ ZORBAX Eclipse XDB reversed phase <strong>HPLC</strong> columns (80 Å)<br />
2.1 50 3.5 971700-902 971700-906<br />
2.1 150 3.5 930990-902 930990-906<br />
2.1 50 5 960967-902 960967-906 960967-912<br />
2.1 150 5 993700-902 993700-906 993700-912<br />
3.0 150 3.5 963954-302 963954-306 963954-312<br />
3.0 150 5 993967-302 993967-306 993967-312<br />
3.0 250 5 990967-302 990967-306 990967-312<br />
4.6 15 3.5 931975-902 931975-906<br />
4.6 15 3.5 931975-932 1 931975-936 1<br />
4.6 30 3.5 933975-902 933975-906<br />
4.6 30 3.5 933975-932 1 933975-936 1<br />
4.6 50 3.5 935967-902 935967-906 935967-912<br />
4.6 75 3.5 966967-902 966967-906 966967-912<br />
4.6 75 3.5 7995118-344 7995108-344<br />
4.6 150 3.5 963967-902 963967-906 963967-912<br />
4.6 50 5 946975-902 946975-906<br />
4.6 150 5 993967-902 993967-906 993967-912<br />
4.6 150 5 7995118-595 7995108-595<br />
4.6 250 5 990967-902 990967-906 990967-912<br />
4.6 250 5 7995118-585 7995108-585<br />
9.4 250 5 990967-202 990967-206<br />
ZORBAX Eclipse XDB guard cartridges<br />
Inner diameter Length Particle size XDB-C18 XDB-C8 XDB-Phenyl<br />
[mm] [mm] [µm] USP (L1) USP (L7) USP (L11)<br />
0.3 35 5 5064-8297<br />
0.5 35 5 5064-8296<br />
2.1 12.5 5 821125-926 1,3 821125-926 1 821125-926 1,3<br />
4.0 4 5 7995118-504 2<br />
4.6 12.5 5 820950-925 1 820950-926 1 820950-927 1<br />
1 Pack of 4 2 Pack of 10<br />
3 Guard Cartridge pn 821125-926 is packed with Eclipse XDB-C8 <strong>and</strong> recommended where listed.
ZORBAX Bonus-RP reversed phase <strong>HPLC</strong> columns (80 Å)<br />
Inner diameter Length Particle size<br />
(mm) (mm) (µm) Bonus-RP<br />
1.0 30 3.5 861608-901<br />
1.0 50 3.5 865608-901<br />
1.0 150 3.5 863608-901<br />
2.1 50 3.5 861700-901<br />
2.1 50 5 861971-901<br />
2.1 150 5 883725-901<br />
4.6 75 3.5 866668-901<br />
4.6 150 3.5 863668-901<br />
4.6 150 5 883668-901<br />
4.6 250 5 880668-901<br />
ZORBAX Bonus-RP guard cartridges<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Bonus-RP<br />
1 Pack of 4<br />
2.1 12.5 5 821125-928 1<br />
4.6 12.5 5 820950-928 1<br />
ZORBAX Extend-C18 <strong>HPLC</strong> columns<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Extend-C18<br />
1.0 30 3.5 761600-902<br />
1.0 50 3.5 765600-902<br />
1.0 150 3.5 763600-902<br />
2.1 50 3.5 735700-902<br />
2.1 50 5 760450-902<br />
2.1 150 5 773700-902<br />
4.6 50 3.5 735953-902<br />
4.6 75 3.5 766953-902<br />
4.6 150 3.5 763953-902<br />
4.6 50 5 746450-902<br />
4.6 150 5 773450-902<br />
4.6 250 5 770450-902<br />
For 300Extend-C18, see biotechnology section<br />
15
16<br />
ZORBAX Extend-C18 guard cartridges<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Extend-C18<br />
1 Pack of 4<br />
Reversed phase columns<br />
2.1 12.5 5 821125-930 1<br />
4.6 12.5 5 820950-930 1<br />
Rapid Resolution cartridge columns <strong>for</strong> LC/MS, LC/MS/MS <strong>and</strong> combinatorial chemistry <strong>and</strong> fast analysis<br />
Inner diameter Length Particle size SB-C18 SB-C8 XDB-C18 XDB-C8<br />
[mm] [mm] [µm] USP (L1) USP (L7) USP (L1) USP (L7)<br />
2.1 15 3.5 875700-902 875700-906 975700-902 975700-906<br />
2.1 15 3.5 875700-932 1 875700-936 1 975700-932 1 975700-936 1<br />
2.1 30 3.5 873700-902 873700-906 973700-902 973700-906<br />
2.1 30 3.5 873700-932 1 873700-936 1 973700-932 1 973700-936 1<br />
4.6 15 3.5 831975-902 831975-906 931975-902 931975-906<br />
4.6 15 3.5 831975-932 1 831975-936 1 931975-932 1 931975-936 1<br />
4.6 30 3.5 833975-902 833975-906 933975-902 933975-906<br />
4.6 30 3.5 833975-9321 833975-9361 933975-9321 933975-9361 2<br />
1 Pack of 3<br />
2 Requires hardware kit 820222-901<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
ZORBAX Rx Reversed phase <strong>HPLC</strong> columns (80 Å)<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Rx-C18 Rx-C8<br />
2.1 150 5 883700-902 883700-906<br />
3.0 150 5 883967-302 883975-306<br />
3.0 250 5 880967-302 880975-306<br />
4.6 75 3.5 866967-902 866953-906<br />
4.6 150 3.5 863967-902 863953-906<br />
4.6 150 5 883967-902 883967-901<br />
4.6 250 5 880967-902 880967-901<br />
9.4 250 5 880967-202 880967-201<br />
21.2 250 7 880967-102 880967-106
Rx guard cartridges 1<br />
(80 Å)<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Rx-C18 Rx-C8<br />
2.1 12.5 5 821125-926 2 821125-926 2<br />
4.6 12.5 5 820950-914 820950-913<br />
9.4 15 7 820675-1153 820675-1153 Rx-C8 is identical to SB-C8. See StableBond <strong>for</strong> additional column choices<br />
1 Analytical guard cartridges are pack of 4; preparative guard cartridges are pack of 2. 2 Guard cartridge pn 821125-926 is packed with Eclipse XDB-C8 <strong>and</strong><br />
recommended where listed 3 Guard cartridge pn 820675-115 is packed with SB-C8 <strong>and</strong> recommended where listed.<br />
ZORBAX Original reversed phase <strong>HPLC</strong> columns (70 Å)<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] ODS (C18) C8 Phenyl CN TMS<br />
3.0 150 5 883952-302<br />
3.0 250 5 880952-302<br />
4.6 150 5 883952-702 883952-706 883952-712 884950-526 883952-710<br />
4.6 250 5 880952-702 880952-706 880952-712 884950-507 880952-710<br />
4.6 250 5 884950-543 1<br />
6.2 80 3 880953-902 880953-906<br />
9.4 250 5 880952-202 880952-206 880952-212 880952-205<br />
21.2 250 7 880952-102 880952-106 880952-105<br />
1 Non-endcapped<br />
ZORBAX original guard cartridges 1<br />
(70 Å)<br />
Inner diameter Length Particle size<br />
(mm) (mm) (µm) ODS (C18) C8 PHENYL CN TMS<br />
4.6 12.5 5 820950-902 820950-906 820950-912 820950-905 820950-924<br />
9.4 15 7 820675-1152 820675-1152 820675-1152 820675-1242 1 Analytical guard cartridges are pack of 4; preparative guard cartridges are pack of 2. 2 Preparative Guard pn 820675-115 is packed with SB-C8 <strong>and</strong> recommended<br />
where listed; pn 820950-124 is packed with 300SB-C3 <strong>and</strong> recommended where listed.<br />
17
18<br />
Microbore <strong>and</strong> capillary <strong>HPLC</strong> columns<br />
ZORBAX StableBond st<strong>and</strong>ard fitting columns<br />
Inner diameter Length Particle size StableBond 80 Å StableBond 300 Å<br />
[mm] [mm] [µm] SB-C18 SB-C8 300SB-C18 300SB-C8<br />
2.1 50 3.5 871700-902 871700-906 865750-902 865750-906<br />
1.0 30 3.5 861600-902 861600-906<br />
1.0 50 3.5 865600-902 865600-906 865630-902 865630-906<br />
1.0 150 3.5 863600-902 863600-906 863630-902 863630-906<br />
Glass-lined 0.3 <strong>and</strong> 0.5 mm columns<br />
ZORBAX StableBond glass-lined columns<br />
Inner diameter Length Particle size StableBond 80 Å StableBond 300 Å<br />
[mm] [mm] [µm] SB-C18 300SB-C18<br />
0.3 150 3.5 5064-8261 5064-8267<br />
0.3 150 5 5064-8255 5064-8263<br />
0.3 250 5 5064-8257 5064-8265<br />
0.5 35 3.5 5064-8260<br />
0.5 150 3.5 5064-8262 5064-8268<br />
0.5 150 5 5064-8256 5064-8264<br />
0.5 250 5 5064-8258 5064-8266<br />
ZORBAX StableBond glass-lined guard-columns<br />
Inner diameter Length Particle size StableBond 80 Å StableBond 300 Å<br />
[mm] [mm] [µm] SB-C18 300SB-C18<br />
0.3 35 5 5064-8253 5064-8295<br />
0.5 35 5 5064-8254 5064-8294
St<strong>and</strong>ard fitting MicroBore columns<br />
Inner diameter Length Particle size ZORBAX ZORBAX ZORBAX ZORBAX<br />
[mm] [mm] [µm] Bonus-RP Extend-C18 Eclipse XDB-C18 Eclipse XDB-C8<br />
1.0 30 3.5 861608-901 761600-902 961600-902 961600-906<br />
1.0 50 3.5 865608-901 765600-902 965600-902 965600-906<br />
1.0 150 3.5 863608-901 763600-902 963600-902 963600-906<br />
Capillary glass-lined columns<br />
Inner diameter Length Particle size ZORBAX Hypersil<br />
[mm] [mm] [µm] Eclipse XDB-C18 ODS<br />
1 3 µm particle<br />
0.3 150 3.5 5064-8271 5064-8277 1<br />
0.3 150 5 5064-8291 5064-8290<br />
0.3 250 5 5064-8269 5064-8276<br />
0.5 35 3.5 5064-8298 5064-8299 1<br />
0.5 150 3.5 5064-8288 5064-8275 1<br />
0.5 150 5 5064-8287 5064-8289<br />
0.5 250 5 5064-8286 5064-8278<br />
Capillary glass-lined guard-columns<br />
Inner diameter Length Particle size ZORBAX Hypersil<br />
[mm] [mm] [µm] Eclipse XDB-C18 ODS<br />
0.3 35 5 5064-8297 5064-8279<br />
0.5 35 5 5064-8296 5064-8282<br />
19
20<br />
Attached to an LC column, the<br />
column identification module<br />
(CIM) communicates with the<br />
Agilent 1100 Series control<br />
module <strong>and</strong> Agilent ChemStation<br />
through a built-in read/write<br />
device. Column usage data is<br />
recorded electronically in the<br />
module. With constant updating,<br />
<strong>HPLC</strong> columns with column identification module<br />
<strong>HPLC</strong> columns with column identification module<br />
column in<strong>for</strong>mation is always<br />
current. Automatic column<br />
tracking enhances the Agilent<br />
1100 Series features <strong>for</strong> meeting<br />
GLP, cGMP <strong>and</strong> quality st<strong>and</strong>ard<br />
requirements, <strong>and</strong> <strong>for</strong> achieving<br />
fast, trouble-free validation.<br />
Inner diameter Length Particle size Hypersil Hypersil<br />
[mm] [mm] [µm] ODS BDS-C18<br />
2.1 100 5 7981618-552<br />
4.0 100 3 79826BD-354<br />
250 79826BD-384<br />
125 5 7982618-564<br />
250 7982618-584<br />
4.6 100 5 7981618-554<br />
Description Part no.<br />
Column identification module<strong>for</strong> any <strong>HPLC</strong> column, pack of 3 5062-8588
Reversed phase columns<br />
Hypersil reversed phase <strong>HPLC</strong> columns<br />
Inner diameter Length Particle size Hypersil Hypersil Hypersil Hypersil Hypersil Hypersil<br />
[mm] [mm] [µm] BDS-C18 BDS-C8 BDS W/CIM ODS ODS W/CIM MOS<br />
0.3 150 3 5064-8277<br />
0.3 150 5 5064-8290<br />
0.3 250 5 5064-8276<br />
0.5 35 3 5064-8299<br />
0.5 150 3 5064-8275<br />
0.5 150 5 5064-8289<br />
0.5 250 5 5064-8278<br />
2 125 3 79926BD-362 7992618-362<br />
2 125 5 79926BD-562 79926B8-562 7992618-562<br />
2 250 5 79926BD-582 79926B8-582 7992618-582<br />
2.1 100 3 79916OD-352<br />
2.1 100 5 79916OD-552 7981618-552 79916MO-552<br />
2.1 200 5 79916OD-572 79916MO-572<br />
3 125 3 79926BD-363 7992618-363<br />
4 75 3 79926BD-344 79926B8-344<br />
4 100 3 79926OB-354 79826BD-354 79926OD-354<br />
4 125 5 79926OB-564 79926B8-564 79926OD-564 7982618-564<br />
4 250 5 79926OB-584 79926B8-584 79826BD-584 79926OD-584 7982618-584<br />
4.6 60 3 79916OD-344<br />
4.6 100 3 79916BD-354<br />
4.6 100 5 799160D-554 7981618-554<br />
4.6 150 5 79926BD-595 7992618-595<br />
4.6 200 5 79916OD-574 79916MO-574<br />
4.6 250 5 79916BD-584 7991618-584<br />
4.6 250 5 79926BD-585 7992618-585<br />
Hypersil reversed phase guard cartridge<br />
Inner diameter Length Particle size Hypersil Hypersil Hypersil<br />
[mm] [mm] [µm] ODS MOS BDS<br />
0.3 35 5 5064-8279<br />
0.5 35 5 5064-8282<br />
2.1 20 5 79916KT-110 1 79916KT-111 1<br />
4 4 5 7992618-504 2 79926BD-504 2<br />
4 20 5 79916KT-120 1 79916KT-121 1<br />
1 Pack of 3 2 Pack of 10<br />
21
22<br />
Reversed phase columns<br />
LiChrospher reversed phase <strong>and</strong> normal phase <strong>HPLC</strong> columns<br />
Inner diameter Length Particle size LiChrospher LiChrospher LiChrospher LiChrospher LiChrospher<br />
[mm] [mm] [µm] RP-C18 RP-C18 RP-8 RP-SELECT B CN<br />
endcapped<br />
1 Pack of 3<br />
3 125 5 7992518-563 79925SB-563<br />
3 250 5 7992518-583 79925SB-583<br />
4 125 5 79925ODE-564 1 79925SB-564 79925CN-564<br />
4 125 5 79925OD-564-3 1 79925MO-564-3 1 79925SB-56K 1<br />
4 250 5 79925OD-584 79925ODE-584 79925MO-584 79925SB-584 79925CN-584<br />
4 250 5 79925OD-58K1 79925OE-58K1 79925MO-58K1 79925SB-58K1 LiChrospher guard cartridges<br />
Inner diameter Length Particle size LiChrospher LiChrospher LiChrospher LiChrospher<br />
[mm] [mm] [µm] RP-18 RP-8 RP-SELECT B CN<br />
4 4 5 79925OD-5041 79925MO-5041 79925SB-5041 79925CN-5041 1 Pack of 10<br />
Purospher Reversed phase <strong>HPLC</strong> columns<br />
Inner diameter Length Particle size Purosper Purospher<br />
[mm] [mm] [µm] RP-18 RP-18 endcapped<br />
4 125 5 79925PU-564 79925PE-564<br />
4 250 5 79925PU-584 79925PE-584<br />
Purospher guard cartridges<br />
Inner diameter Length Particle size Purospher Purospher<br />
[mm] [mm] [µm] RP-18 RP-18 endcapped<br />
4 4 5 79925PU-5041 79925PE-5041 1 Pack of 10<br />
Inertsil Reversed phase <strong>HPLC</strong> columns<br />
Inner diameter Length Particle size Inertsil<br />
[mm] [mm] [µm] ODS-2<br />
2 125 5 7993318-562<br />
2 250 5 7993318-582<br />
4 125 5 7993318-564<br />
4 250 5 7993318-584
LiChrosorb Reversed phase <strong>HPLC</strong> column<br />
Inner diameter Length Particle size LiChrosorb LiChrosorb<br />
[mm] [mm] [µm] RP-C18 RP-C8<br />
4.6 200 5 79915OD-574 79915MO-574<br />
4.6 200 10 79915OD-174 79915MO-174<br />
Nucleosil Reversed phase <strong>HPLC</strong> column<br />
Inner diameter Length Particle size Nucleosil<br />
[mm] [mm] [µm] 100-5 C18<br />
4 125 5 7992718-564<br />
4 250 5 7992718-584<br />
Nucleosil guard cartridge<br />
Inner diameter Length Particle size Nucleosil<br />
[mm] [mm] [µm] 100-5 C18<br />
4 4 5 7992718-5041 1 Pack of 10<br />
Asahipak Reversed phase <strong>HPLC</strong> columns<br />
Inner diameter Length Particle size Asahipak<br />
[mm] [mm] [µm] ODP-50<br />
2 125 5 7992318-562<br />
4 125 5 79923OP-564<br />
4 250 5 79923OP-584<br />
Superspher Reversed phase <strong>HPLC</strong> columns<br />
Inner diameter Length Particle size Supersphere Supersphere Supersphere<br />
[mm] [mm] [µm] 60 RP-SELECT B 100 RP-18 RP-18 encapped<br />
2 125 4 79925SB-462 7992518-462 79925EC-462<br />
2 250 4 79925SB-482 7992518-482 79925EC-482<br />
4 125 4 79925SB-464 79925OD-464<br />
4 250 4 79925SB-484 7992518-484<br />
Superspher guard cartridges<br />
Inner diameter Length Particle size Supersphere Supersphere<br />
[mm] [mm] [µm] 60 RP-SELECT B 100 RP-18<br />
2 10 4 79925SB-402 7992518-402<br />
23
24<br />
Normal phase <strong>and</strong> chiral columns<br />
ZORBAX Normal phase <strong>HPLC</strong> columns<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Rx-SIL SIL CN NH 2<br />
1 Pack of 3<br />
4.6 150 5 883975-901 883952-701 883952-705 883952-708<br />
4.6 250 5 880975-901 880952-701 880952-705 880952-708<br />
6.2 80 3 880953-901<br />
9.4 250 5 880975-201 880952-201 880952-205 880952-208<br />
21.2 250 7 880975-101 880952-101 880952-105 880952-108<br />
ZORBAX guard cartridges 1<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Rx-SIL SIL CN NH 2<br />
2.1 12.5 5 821125-919<br />
4.6 12.5 5 820950-919 820950-901 820950-905 820950-908<br />
9.4 15 7 820675-1192 820675-1192 820675-1112 820675-1112 1 Analytical guard cartridges are pack of 4; preparative guard cartridges are pack of 2. 2 Preparative guard cartridge pn 820675-119 is packed with Rx-SIL <strong>and</strong><br />
recommended where listed; pn 820675-111 is packed with DiOL <strong>and</strong> recommended where listed.<br />
Hypersil Silica Normal phase <strong>HPLC</strong> columns<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Hypersil APS (NH 2) Hypersil<br />
2.1 100 5 79916AP-552 79916SI-552<br />
2.1 200 5 79916SI-572<br />
4.6 100 5 79916AP-554 79916SI-554<br />
4.6 200 5 79916AP-574 79916SI-574<br />
Hypersil guard cartridges<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Hypersil APS (NH 2) Hypersil<br />
1 Pack of 3<br />
2.1 20 5 79916KT-112 1 79916KT-113 1<br />
4 20 5 79916KT-122 1 79916KT-123 1
LiChrospher Normal phase <strong>HPLC</strong> column<br />
Inner diameter Length Particle size LiChrospher LiChrospher LiChrospher LiChrospher<br />
[mm] [mm] [µm] CN DIOL NH 2 Si<br />
4 125 5 79925CN-564 79925DI-564 79925AP-564 79925SI-564<br />
4 250 5 79925CN-584 79925DI-584 79925AP-584 79925SI-584<br />
LiChrospher guard cartridges<br />
Inner diameter Length Particle size LiChrospher LiChrospher LiChrospher<br />
[mm] [mm] [µm] CN NH2 Si<br />
4 4 5 79925CN-504 79925AP-504 79925SI-504<br />
1 Pack of 10<br />
Ultron ES chiral columns<br />
Inner diameter Length Particle size Ultron Ultron ES-OVM Ultron Ultron ES-Pepsin<br />
[mm] [mm] [µm] ES-OVM with guard ES-Pepsin with guard<br />
2.0 150 5 702111610<br />
4.6 150 5 702111651 822111651<br />
4.6 150 5 702111651A 822111631A<br />
6.0 150 5 702111668<br />
Ultron ES chiral guard column<br />
Inner diameter Length Particle size Ultron Ultron<br />
[mm] [mm] [µm] ES-OVM ES-Pepsin<br />
4.0 10 5 712111630 832111630<br />
ChiraDex cartridge column<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] ChiraDex<br />
4.0 250 5 79925CB-584<br />
25
26<br />
Gel permeation chromatography columns<br />
ZORBAX Single Pore Size PSM (Porous Silica Microspheres) GPC <strong>Columns</strong><br />
Inner diameter Length Particle size Molecular<br />
[mm] [mm] [µm] weight range Silanized Description Part No.<br />
6.2 250 5 5 x 102 –1 x 104 no PSM 60 880957-801<br />
yes PSM 60S 880957-802<br />
6.2 250 5 3 x 103 –3 x 105 no PSM 300 880957-805<br />
yes PSM 300S 880957-806<br />
6.2 250 5 1 x 104 –1 x 106 no PSM 1000 880957-807<br />
yes PSM 1000S 880957-808<br />
6.2 250 5 1 x 105 –1 x 107 no PSM 3000 880957-809<br />
yes PSM 3000S 880957-810<br />
ZORBAX Mixed Bed PSM<br />
Inner diameter Length Particle size Molecular<br />
[mm] [mm] [µm] weight range Silanized Description Part No.<br />
6.2 250 5 5 x 102 –1 x 106 no Bimodal 880957-813<br />
Bimodal-kit1 880949-903<br />
yes Bimodal-S 880957-814<br />
Bimodal-kit-S1 880949-904<br />
6.2 250 5 5 x 102 –1 x 107 no Trimodal-kit1 880949-905<br />
yes Trimodal-S 880957-818<br />
Trimodal-kit-S1 880949-906<br />
1 Kits contain two columns <strong>and</strong> a column connector.<br />
PLgel Mixed Bed GPC columns<br />
Inner diameter Length Particle size Mid-Weight<br />
[mm] [mm] [µm] Range Part No.<br />
7.5 300 3 up to 30 K 79911GP-MXE<br />
7.5 300 5 200–400 K 79911GP-MXD<br />
200–3 M 79911GP-MXC<br />
7.5 300 10 500–10 M 79911GP-MXB<br />
7.5 300 20 1,000–40 M 79911GP-MXA<br />
PLgel Guard <strong>Columns</strong> <strong>and</strong> Accessories<br />
Inner Diameter Length Particle Size Ordering<br />
[mm] [mm] [µm] Notes Part No.<br />
7.5 50 5 79911GP-510<br />
10 79911GP-110<br />
Frits <strong>and</strong> screens, 1 piece end fitting pack of 5 1535-4863
PLgel Individual Pore Sized GPC <strong>Columns</strong><br />
Inner diameter Length Particle size Pore size Mid-weight<br />
[mm] [mm] [µm] [Å] range Part No.<br />
7.5 300 5 50 < 1000D 79911GP-500<br />
7.5 300 5 100 < 4000D 79911GP-501<br />
7.5 300 5 500 500D–20KD 79911GP-502<br />
7.5 300 5 1 000 1KD–40KD 79911GP-503<br />
7.5 300 5 10 000 4KD–400KD 79911GP-504<br />
7.5 300 5 100 000 40KD–4MD 79911GP-505<br />
7.5 300 10 50 < 1 000D 79911GP-100<br />
7.5 300 10 100 < 4 000D 79911GP-101<br />
7.5 300 10 500 500D–20KD 79911GP-102<br />
7.5 300 10 1 000 1KD–40KD 79911GP-103<br />
7.5 300 10 10 000 4KD–400KD 79911GP-104<br />
7.5 300 10 100 000 40KD–4MD 79911GP-105<br />
7.5 300 10 1 000 000 400KD–40MD 79911GP-106<br />
PL aquagel-OH columns<br />
Inner diameter Length Particle size Pore size Weight<br />
[mm] [mm] [µm] [Å] range Part No.<br />
7.5 300 8 30 100–30K 79911GF-083<br />
7.5 300 8 40 10–200K 79911GF-084<br />
7.5 300 8 50 50K–1M 79911GF-085<br />
7.5 300 8 60 200K–10K 79911GF-086<br />
7.5 300 8 Mixed 100–10M 79911GF-MXA<br />
PL aquagel-OH guard column<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Part No.<br />
7.5 50 8 79911GF-080<br />
Polymer st<strong>and</strong>ards <strong>and</strong> broad test samples<br />
Description Part No.<br />
Polystyrene EasiCal vial st<strong>and</strong>ards (organic st<strong>and</strong>ards), 10 x 3 vials 5064-8281<br />
Polyethylene oxide EasiCal vial st<strong>and</strong>ards (aqueous st<strong>and</strong>ards), 10 x 3 vials 5064-8252<br />
Polystyrene EasiCal vial test sample (organic test), 10 x 3 vials 5065-4412<br />
Dextran EasiCal vial test sample (aqueous test), 10 x 3 vials 5065-4411<br />
GPC-SEC Start-up Kits<br />
Description Part No.<br />
Organic GPC-SEC Start-up Kit 5064-8251<br />
Includes:PLgel Mixed-C column 300 x 7.5, st<strong>and</strong>ards, test sample, manual<br />
Aqueous SEC Start-up Kit 5064-8252<br />
Includes PL aquagel-OH Mixed column 300 x 7.5, st<strong>and</strong>ards, test sample, manual<br />
27
28<br />
Reversed phase <strong>HPLC</strong> columns <strong>for</strong> bio science<br />
Wide-Pore ZORBAX StableBond (300 Å) Reversed Phase <strong>Columns</strong><br />
Inner diameter Length Particle size 300SB-C18 300SB-C8 300SB-C3 300SB-CN<br />
[mm] [mm] [µm] USP (L1) USP (L7) USP (L10)<br />
0.3 150 3.5 5064-8267<br />
0.3 150 5 5064-8263<br />
0.3 250 5 5064-8265<br />
0.5 150 3.5 5064-8268<br />
0.5 150 5 5064-8264<br />
0.5 250 5 5064-8266<br />
1.0 50 3.5 865630-902 865630-906<br />
1.0 150 3.5 863630-902 863630-906<br />
2.1 50 3.5 865750-902 865750-906<br />
2.1 150 5 883750-902 883750-906 883750-909 883750-905<br />
4.6 50 3.5 865973-902 865973-906 865973-909 865973-905<br />
4.6 150 3.5 863973-902 863973-906 863973-909 863973-905<br />
4.6 50 5 860950-902 860950-906 860950-909 860950-905<br />
4.6 150 5 883995-902 883995-906 883995-909 883995-905<br />
4.6 250 5 880995-902 880995-906 880995-909 880995-905<br />
9.4 250 5 880995-202 880995-206 880995-209 880995-205<br />
21.2 250 7 880995-102 880995-106 880995-109 880995-105<br />
StableBond (300Å) Guard Cartridges<br />
Inner diameter Length Particle size Ordering<br />
[mm] [mm] [µm] 300SB-C18 300SB-C8 300SB-C3 300SB-CN Notes<br />
0.3 35 5 5064-8295<br />
0.5 35 5 5064-8294<br />
2.1 12.5 5 821125-918 1 821125-918 1 821125-924 2 821125-924 2 pack of 4<br />
4.6 12.5 5 820950-921 820950-918 820950-924 820950-923 pack of 4<br />
9.4 15 7 820675-1243 820675-1243 820675-1243 820675-1243 pack of 2<br />
1 Guard cartridge pn 821125-918 is packed with 300SB-C8 <strong>and</strong> recommended where listed. 2 Guard cartridge pn 821125-924 is packed with 300SB-C3 <strong>and</strong><br />
recommended where listed. 3 Guard cartridge pn 820675-124 is packed with 300SB-C3 <strong>and</strong> recommended where listed.
ZORBAX 300 Extend-C18 columns<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Part no.<br />
2.1 50 3.5 765750-902<br />
2.1 150 3.5 763750-902<br />
4.6 50 3.5 765973-902<br />
4.6 150 3.5 763973-902<br />
4.6 150 5 773995-902<br />
4.6 250 5 770995-902<br />
ZORBAX 300 Extend-C18 guard cartridges<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Part no.<br />
1 Pack of 4<br />
4.6 12.5 5 820950-932 1<br />
2.1 12.5 5 821125-932 1<br />
Synchropak <strong>Columns</strong><br />
Inner diameter Length Particle size Pore Synchropak Synchropak Synchropak<br />
[mm] [mm] [µm] size C4 C8 C18<br />
4.6 100 6.5 300Å Silica 79919B3-554 79919M3-554 79919O3-554<br />
4.6 250 6.5 300Å Silica 79919B3-584 79919M3-584 79919O3-584<br />
Vydac <strong>Columns</strong><br />
Inner diameter Length Particle size Pore Vydac Vydac<br />
[mm] [mm] [µm] size C4 (214 TP) C18 (218 TP)<br />
1 250 5 300Å Silica 79918O3-581<br />
2.1 250 5 300Å Silica 79918O3-582<br />
4.6 150 5 300Å Silica 79918B3-564 79918O3-584<br />
4.6 250 5 300Å Silica 79918B3-584 79918O3-584<br />
10.0 250 5 300Å Silica 79918B3-588 79918O3-588<br />
29
30<br />
<strong>Columns</strong> <strong>for</strong> biomolecules – gel filtration columns<br />
ZORBAX GF-250 <strong>and</strong> GF-450 Gel Filtration <strong>HPLC</strong> <strong>Columns</strong><br />
Inner diameter Length<br />
[mm] [mm] GF-250 GF-450<br />
4.6 250 884973-701<br />
9.4 250 884973-901 884973-902<br />
21.2 250 884974-901 884974-910<br />
ZORBAX Gel Filtration Guard Cartridges 1<br />
Inner diameter Length<br />
[mm] [mm] GF-250 GF-450<br />
4.6 12.5 820950-911 820950-911<br />
9.4 15 820675-111 820675-111<br />
1Guard cartridges are packed with Diol <strong>and</strong> recommended where listed. Analytical guards<br />
are pack of 4; preparative guards are pack of 2.<br />
TSK Gel Filtration <strong>Columns</strong><br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] 2000SW 2000SW-XL 3000SW 3000SW-XL 4000SW<br />
7.5 300 10 79912S2-197 79912S3-197 79912S4-197<br />
7.5 600 10 79912S2-107 79912S3-107 79912S4-107<br />
7.8 300 5 79912S2-597 79912S3-597<br />
21.5 300 13 79912S2-299 79912S3-299 79912S4-299<br />
TSK columns use finger-tight fittings, part number 0100-1516.<br />
TSK Guard <strong>Columns</strong> <strong>for</strong> Gel Filtration<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] 3000SW 3000SW-XL<br />
6.0 40 5 79912S3-527<br />
7.5 75 10 79912S3-147<br />
21.5 75 13 79912S3-249
<strong>Columns</strong> <strong>for</strong> biomolecules – ion exchange <strong>HPLC</strong> columns<br />
ZORBAX Ion Exchange <strong>Columns</strong><br />
Inner diameter Length Particle size ZORBAX ZORBAX ZORBAX<br />
[mm] [mm] [µm] SAX (70 Å) SAX (300 Å) SCX (300 Å)<br />
4.6 150 5 883952-703 883952-704<br />
4.6 250 5 880952-703 880952-704<br />
6.2 80 6 820944-903 820944-904<br />
9.4 250 5 880952-203 880952-204<br />
ZORBAX Ion Exchange Guard Cartridges 1<br />
Inner diameter Length Particle size ZORBAX ZORBAX<br />
[mm] [mm] [µm] SAX (70 Å) SCX (300 Å)<br />
4.6 12.5 5 820950-903 820950-904<br />
1 Pack of 4<br />
Anion Exchange Column<br />
Inner diameter Length Particle size pH TSK TSK PL 1000 SynChropak SynChropak<br />
[mm] [mm] resin [µm] range DEAE-5PW DEAE NPR SAX WAX SAX<br />
4.6 35 2.5 2–12 79912DE-324<br />
4.6 100 6.5 2–8 79919DE-754 79919QA-754<br />
4.6 250 6.5 2–8 79919DE-784 79919QA-784<br />
5.0 50 8 1–13 79931QA-835<br />
7.5 75 10 2–12 79912DE-147<br />
21.5 150 10 2–12 79912DE-169<br />
Cation Exchange Column<br />
Inner diameter Length Particle size pH TSK TSK PL 1000 SynChropak SynChropak<br />
[mm] [mm] resin [µm] range DEAE-5PW DEAE NPR SAX WAX SAX<br />
4.6 35 2.5 2–12 79912SP-324<br />
4.6 100 6.5 2–8 79919CM-754 79919SP-754<br />
4.6 250 6.5 2–8 79919CM-784 79919SP-784<br />
5.0 50 8 1–13 79931SP-835<br />
7.5 75 10 2–12 79912SP-147<br />
21.5 150 10 2–12 79912SP-169<br />
31
32<br />
TSK nonporous resin columns<br />
Inner diameter Length Particle size<br />
[mm] [mm] resin [µm] TSK DEAE TSK Sulfopropyl TSK C18<br />
4.6 35 2.5 79912DE-324 79912SP-324 79912OD-324<br />
Accessories<br />
Item Part No.<br />
Replacement filter 5062-2435<br />
In-line filter kit 01090-68703<br />
ZORBAX Bio Series oligo analysis columns<br />
Inner diameter Length Particle size<br />
[mm] [mm] [µm] Oligo<br />
6.2 80 5 820940-901<br />
9.4 250 5 884973-903<br />
21.2 250 5 884974-915<br />
Hydrophobic Interaction Chromatography <strong>Columns</strong> (HIC)<br />
Inner diameter Length Particle size pH TSK TSK Synchropak<br />
[mm] [mm] [µm] range PHENYL-5PW ETHER-5PW H-PROPYL<br />
4.6 100 6.5 2–8 79919P3-754<br />
4.6 250 6.5 2–8 79919P3-784<br />
7.5 75 10 2–12 79912PH-147 79912ET-147<br />
21.5 150 10 2–12 79912PH-169<br />
Accessories<br />
<strong>Columns</strong> <strong>for</strong> biomolecules<br />
Item Part No.<br />
H-Propyl packing, 10 g 8501-0098<br />
Pre-column hardware kit <strong>for</strong> self-packing guard columns 79916KT-101<br />
Phenyl guard column kit 79912PH-707
Special applications columns<br />
ZORBAX Eclipse-AAA <strong>HPLC</strong> columns<br />
Inner diameter Length Particle size Guard cartridge<br />
[mm] [mm] [µm] Part no. 12.5 mm long<br />
1 Pack of 4<br />
3.0 150 3.5 961400-302<br />
4.6 75 3.5 966400-902<br />
4.6 150 3.5 963400-902<br />
4.6 150 5 993400-902 820950-9311 ZORBAX Carbohydrate analysis columns<br />
Inner diameter Length Particle size ZORBAX NH 2 Guard cartridge<br />
[mm] [mm] [µm] Part no. 12.5 mm long<br />
4.6 150 5 843300-908 820950-908<br />
4.6 250 5 840300-908<br />
ZORBAX Eclipse dsDNA analysis columns<br />
Inner diameter Length Particle size Guard cartridge<br />
[mm] [mm] [µm] Part no. 12.5 mm long<br />
2.1 75 3.5 945750-902 821125-929<br />
2.1 150 3.5 993850-902<br />
3.0 75 3.5 945750-302<br />
4.6 75 3.5 992750-902 820950-929<br />
Special application columns<br />
Inner diameter Length Particle size Application<br />
[mm] [mm] [µm] Amino Acid PTH PAH<br />
2.1 200 5 79916AA-572<br />
2.1 250 5 79916PT-582 79918PAH-582<br />
3.0 250 5 79925PA-583<br />
4.6 50 3 79918PA-344<br />
4.6 250 5 79918PAH-584<br />
Guard cartridges <strong>for</strong> special columns<br />
Inner diameter Length Particle size Ordering<br />
[mm] [mm] [µm] Amino acid PAH notes<br />
2.1 20 5 79916KT-110 pack of 3<br />
2.1 30 5 79918PH-5321 pack of 2<br />
4.6 30 5 79918PH-5341 pack of 2<br />
1 Reusable guard cartridge holder pn 79918PH-100<br />
33
34<br />
<strong>HPLC</strong> column kits<br />
Agilent Cartridge System Starter Kits<br />
Item Part No.<br />
ZORBAX C-18 Kit containing 5183-2021<br />
One Eclipse XDB-C18 column 4.6 x 150 mm, 5 µm<br />
One StableBond C18 column 4.6 x 150 mm, 5 µm<br />
Cartridge holder, mounting tool, replacement filter (2/pk),<br />
open end wrench<br />
ZORBAX C-8 Kit containing 5183-2022<br />
One Eclipse XDB-C8 column 4.6 x 150 mm, 5 µm<br />
One StableBond C8 column 4.6 x 150 mm, 5 µm<br />
Cartridge holder, mounting tool, replacement filter (2/pk),<br />
open end wrench<br />
Hypersil ODS Kit 79926KT-100<br />
Cartridge Starter Kit Hypersil ODS, 5 µm containing<br />
Hypersil ODS, 125 x 4 mm<br />
Hypersil ODS, 250 x 4 mm<br />
Cartridge holder, mounting tool, replacement filter (2/pk),<br />
open end wrench
Method Development Kits<br />
Item Part No.<br />
Traditional StableBond Kit including 5183-4624<br />
3 columns, 4.6 x 150 mm packed with<br />
SB-C18, 5 µm; SB-C8, 5 µm; SB-Phenyl, 5 µm<br />
StableBond Kit <strong>for</strong> fast Analysis including 5183-4625<br />
3 columns, 4.6 x 75 mm packed with<br />
SB-C18, 3.5 µm; SB-C8, 3.5 µm; SB-Phenyl, 3.5 µm<br />
Traditional Eclipse XDB Kit including 5183-4626<br />
3 columns, 4.6 x 150 mm packed with<br />
XDB-C18, 5 µm; XDB-C8, 5 µm; XDB-Phenyl, 5 µm<br />
Eclipse XDB Kit <strong>for</strong> fast <strong>HPLC</strong> including 5183-4627<br />
3 columns, 4.6 x 75 mm packed with<br />
XDB-C18, 3.5 µm; XDB-C8, 3.5 µm; XDB-Phenyl, 3.5 µm<br />
Reversed-Phase Method Development Kit – 4 mm id including 5063-6516<br />
4 cartridges, 125 x 4 mm, packed with<br />
Hypersil ODS, 5 µm; Hypersil BDS-C18, 5 µm;<br />
LiChrospher RP-8, 5 µm; Nucleosil C 18, 5 µm<br />
10 guard cartridges, cartridge holder, 10 replacement filters,<br />
mounting tool <strong>for</strong> replacing the filters<br />
PEEK tubing (0.18 mm id), 4 PEEK fittings<br />
LC trouble shooting guide <strong>and</strong> the supplies catalog on CD-ROM<br />
Reversed-Phase Method Development Kit – 2 mm id including 5063-6529<br />
4 cartridges, 125 x 2 mm, packed with<br />
Hypersil BDS-C18, 5 µm; Hypersil BDS-C18, 3 µm;<br />
Hypersil ODS, 3 µm; Superspher select B, 4 µm<br />
3 guard cartridges, cartridge holder, 10 replacement filters,<br />
mounting tool <strong>for</strong> replacing the filters<br />
PEEK tubing (0.13 mm id), 4 PEEK fittings<br />
LC trouble shooting guide <strong>and</strong> the supplies catalog on CD-ROM<br />
35
36<br />
Connectors<br />
Connecting capillaries<br />
Flexible stainless steel capillaries with 1/16-in male fittings<br />
i. d. Length 280 mm Length 180 mm Length 70 mm Length 35 mm<br />
[mm] Part No. Part No. Part No. Part No.<br />
0.12 01090-87610 G1313-87304 G1316-87303 79841-87609<br />
0.17 01090-87304 G1313-87305 G1316-87300<br />
Flexible stainless steel capillaries without fittings<br />
i. d. Length 105 mm Length 150 mm Length 280 mm Length 400 mm<br />
[mm] Part No. Part No. Part No. Part No.<br />
0.17 (green) 5021-1816 5021-1817 5021-1818 5021-1819<br />
0.12 (red) 5021-1820 5021-1821 5021-1822 5021-1823<br />
Use these capillaries with SS fittings <strong>and</strong> ferrules 5062-2418 (10/pk)<br />
or PEEK fingertight fittings 0100-1516.<br />
Capillary kits<br />
Description Part No.<br />
Capillary kit containing 0.12 mm id capillaries: 5061-3304<br />
3 ea 105 mm long, 1 ea 150 mm long, 1 ea 280 mm long<br />
plus fittings<br />
Capillary kit contains preswaged 0.12 mm id capillaries: 5061-3315<br />
3 ea 70 mm long, 1 ea 280 mm long, 1 ea 35 mm long
PEEK tubing<br />
Description i.d. 0.02 in i.d. 0.01 in i.d. 0.007 in i.d. 0.005 in<br />
(0.5 mm) (0.25 mm) (0.18 mm) (0.13 mm)<br />
Part No. Part No. Part No. Part No.<br />
Tubing 1/16 in. od, 1.5 m 0890-1761 0890-1762 0890-1763 0890-1915<br />
Description Part No.<br />
Cutter <strong>for</strong> plastic tubing 8710-1930<br />
PEEK finger-tight fittings<br />
Description Part No.<br />
Finger-tight fittings, 1/16 in (2/pk) 0100-1516<br />
Finger-tight fittings, 1/16 in (10/pk) 5063-6591<br />
Colored finger-tight fittings, 1/16 in, yellow, blue black green red, 2 each 5065-4426<br />
Finger-tight fittings, long, 1/16 in (10/pk) 5062-8541<br />
Rheflex fittings <strong>for</strong> Rheodyne valves (5/pk) 0100-1631<br />
Double winged nuts <strong>and</strong> 1/32 in ferrule (10/pk) 5065-4422<br />
0100-1516 / 5063-6591<br />
5062-8541<br />
5065-4426<br />
0100-1631<br />
5065-4422<br />
37
38<br />
St<strong>and</strong>ard vials<br />
Vials <strong>and</strong> caps<br />
Volume 100/pk 1000/pk 100/pk (silanized)<br />
Description [ml] Part no. Part no. Part no.<br />
Crimp Clear glass top vials 2 5181-3375 5183-4491 5183-4494<br />
Crimp Clear glass top vials, write-on spot 2 5182-0543 5183-4492 5183-4495<br />
Crimp Amber glass top vials, write-on spot 2 5181-3376 5183-4493 5183-4496<br />
Crimp Polypropylene wide opening top 1 5182-0567<br />
Crimp Polypropylene wide opening top 0,3 9301-0978<br />
Snap Clear glass top vials 2 5182-0544 5183-4504 5183-4507<br />
Snap Clear glass top vials, write-on spot 2 5182-0546 5183-4505 5183-4508<br />
Snap Amber glass top vials, write-on spot 2 5182-0545 5183-4506 5183-4509<br />
Screw Clear glass top vials 2 5182-0714 5183-2067 5183-2070<br />
Screw Clear glass top vials, write-on spot 2 5182-0715 5183-2068 5183-2071<br />
Screw Amber glass top vials, write-on spot 2 5182-0716 5183-2069 5183-2072<br />
Narrow neck vials (recommended <strong>for</strong> HP 1090)<br />
Volume 100/pk<br />
Description [ml] Part no.<br />
Crimp Clear glass top vials, narrow neck 2 5182-0538<br />
Crimp Amber glass top vials, narrow neck 2 5182-0539<br />
6-ml vials <strong>and</strong> caps <strong>for</strong> use with 1100 Series LC<br />
Volume Cap size 100/pk<br />
Description [ml] [mm] Part no.<br />
Clear glass screw cap vials <strong>for</strong> 1100 Series LC 6 16 9301-1377<br />
Clear glass crimp cap vials <strong>for</strong> 1100 Series LC 6 20 9301-1419<br />
Screw caps <strong>for</strong> 6-ml vials 16 9301-1379<br />
PTFE/silicone septa <strong>for</strong> 6-ml vials 16 5183-4668<br />
PTFE/silicone crimp caps <strong>for</strong> 6-ml vials 20 5183-4662
Microvials<br />
Volume Cap size<br />
Description Quantity [ml] [mm] Part No. 1050 1090 1100<br />
Crimp cap microvials with fixed inserts 100 0.2 11 9301-1388 • • •<br />
Microvial inserts (use with narrow neck vials) 500 0.1 9301-1387 • • •<br />
Crimp clear microvials, tapered 500 0.1 8 5180-0844 • •<br />
Crimp clear microvials, round bottom 500 0.3 8 5180-0841 • •<br />
Crimp amber microvials, tapered 500 0.5 8 5180-0806 •<br />
Crimp amber microvials, round bottom 500 0.7 8 5180-0805 •<br />
Sleeves <strong>for</strong> HP 1050 (white) 25 5021-1859 •<br />
Sleeves <strong>for</strong> HP 1090 (black) 10 5180-0843 •<br />
Caps<br />
Description<br />
Crimp (100/pk) (Clear PTFE/red rubber septa)<br />
Part no.<br />
Silver aluminium caps 5181-1210<br />
Silver aluminium caps (1000/pk) 5183-4498<br />
Blue aluminium caps 5181-1215<br />
Green aluminium caps 5181-1216<br />
Red aluminium caps<br />
Screw (100/pk) (Clear PTFE/red rubber septa)<br />
5181-1217<br />
Blue polypropylene caps 5182-0717<br />
Green polypropylene caps 5182-0718<br />
Red polypropylene caps 5182-0719<br />
Vial kits<br />
Description<br />
Snap (100/pk) (Clear PTFE/red rubber septa)<br />
Part no.<br />
Clear polypropylene caps 5182-0550<br />
Blue polypropylene caps 5182-3458<br />
Green polypropylene caps 5182-3457<br />
Red polypropylene caps 5182-3459<br />
Screw (100/pk) (Clear PTFE/silicone septa)<br />
Blue polypropylene caps 5182-0720<br />
Green polypropylene caps 5182-0721<br />
Red polypropylene caps 5182-0722<br />
Description Part No.<br />
2 ml vial kit 01078-68705<br />
100 (2 ml) vials, 100 crimp caps, 1 (11 mm) crimper<br />
Clear crimp top vials, silver aluminium crimp caps, 5181-3400<br />
PTFE/red rubber septa in 6 drawer storage box (500/pk)<br />
Amber crimp top vials with write on spot, silver aluminium crimp caps, 5181-8801<br />
PTFE/red rubber septa in 6 drawer storage box (500/pk)<br />
39
40<br />
Crimper/Decapper<br />
Crimpers <strong>and</strong> decappers<br />
Description Part No.<br />
Crimper <strong>for</strong> 8 mm vials 8710-1643<br />
Crimper <strong>for</strong> 11 mm vials 8710-0979<br />
Crimper <strong>for</strong> 20 mm vials 9301-0720<br />
Decapper <strong>for</strong> 8 mm vials 5181-8827<br />
Decapper <strong>for</strong> 11 mm vials 5181-1213<br />
Decapper <strong>for</strong> 20 mm vials 5181-1214<br />
Crimping/decapping system<br />
Description Part No.<br />
Crimping System, holder without crimp head 5062-2495<br />
Description <strong>for</strong> 9 mm caps <strong>for</strong> 11 mm caps <strong>for</strong> 20 mm caps<br />
Part No. Part No. Part No.<br />
Crimp head 5001-3754 5001-3755 5001-3756<br />
Decapper head 5001-3757 5001-3758 5001-3759
Agilent Technologies’ electronic<br />
crimper <strong>for</strong> 2 mL crimp-top autosampler<br />
vials features:<br />
• Electronic, motor-driven<br />
crimping <strong>for</strong> reproducible<br />
crimps<br />
• H<strong>and</strong>-held, push-button<br />
operation<br />
• Electronic ajustment of the<br />
crimp <strong>for</strong>ce<br />
• Te ability to crimp vials directly<br />
in common autosampler trays<br />
• The ability to crimp hundreds of<br />
vials with a single battery<br />
charge<br />
• Well-known rechargeable<br />
battery technology from Black &<br />
Decker, using the Versapack<br />
Gold Nickel Metal Hybride<br />
battery<br />
• Ergonomic design to minimize<br />
wrist fatigue often encountered<br />
with manual crimpers<br />
Electronic crimper<br />
Description<br />
Electronic crimper complete with one VersaPak Gold<br />
Part No.<br />
rechargeable battery <strong>and</strong> charger 5183-4763<br />
Replacement VersaPak Gold battery 5183-4799<br />
41
42<br />
Solvent filter/degasser<br />
Filters <strong>and</strong> degassers<br />
Description Part No.<br />
Filter degasser assembly with 3150-0507<br />
40-in. long, 1/4-in. od Teflon tubing,<br />
10 filter membranes,<br />
<strong>and</strong> a 1-liter plastic coated graduated solvent reservoir<br />
Solvent filter/degasser<br />
Description Part No.<br />
Solvent filtration kit: 3150-0577<br />
250 ml glass reservoir,<br />
tapered funnel base with PTFE coated sieve,<br />
tapered top,<br />
1000 ml flask <strong>and</strong> clamp<br />
Cellulose filter membranes 3150-0576<br />
47 mm, pore size 0.45 µm (pack of 100)<br />
Nylon filter membranes 9301-0895<br />
47 mm, pore size 0.45 µm (pack of 100)<br />
Teflon filter membranes 3150-0509<br />
47 mm, pore size 2 µm (pack of 10)<br />
<strong>HPLC</strong> in-line filter<br />
Description Part No.<br />
Low-dispersion column inlet filter 01090-68702<br />
with two 2.1 mm frits, 2 µm<br />
connecting capillary<br />
Replacement frits 2.1 mm, 2 µm (10/pk) 5062-8561<br />
Universal solvent filter 01090-68703<br />
with two 4.8 mm frits, 2 µm<br />
connecting capillary<br />
Replacement frits 4.8 mm, 2 µm (2/pk) 01090-27609
Syringe filters<br />
(All membrane filters in packs of 100)<br />
Pre-filters<br />
Diameter Sample volume<br />
[mm] [ml] Membrane Housing Part No.<br />
30 1–50 Glass fiber GF53 Polypropylene 5042-1393<br />
30 1–50 Glass fiber GF92 Polypropylene 5042-1370<br />
Membrane filters<br />
Diameter Pore size Sample volume<br />
[mm] [µm] [ml] Membrane Housing Part No.<br />
30 0.45 1–50 Cellulose acetate Polycarbonate 5061-3363<br />
30 0.45 1–50 Regenerated cellulose Polypropylene 5061-3364<br />
30 0.2 1–50 Regenerated cellulose Polypropylene 5061-3354<br />
30 0.45 1–50 PTFE Polypropylene 3150-0754<br />
30 0.2 1–50 PTFE Polypropylene 3150-0753<br />
13 0.45 1–10 Regenerated cellulose Polypropylene 5061-3365*<br />
13 0.2 1–10 Regenerated cellulose Polypropylene 5061-3366*<br />
13 0.45 1–10 Regenerated cellulose Polypropylene 5064-8221<br />
13 0.2 1–10 Regenerated cellulose Polypropylene 5064-8222<br />
3 0.45 < 1 Nylon Nylon 5061-3367<br />
3 0.2 < 1 Nylon Nylon 5061-3368<br />
* filter with mini-tip. All other filters have male luer tip<br />
2 in 1 filters<br />
Diameter Pore size Sample volume<br />
[mm] [µm] [ml] Membrane Housing Part No.<br />
30 0.45 1–50 Glass fiber<br />
Cellulose nitrate<br />
Polycarbonate 5042-1391<br />
30 0.45 1–50 Glass fiber Polycarbonate 5042-1392<br />
Regenerated cellulose<br />
43
44<br />
Tools <strong>for</strong> 1100 Series LC<br />
Parts <strong>for</strong> 1100 Vacuum degasser<br />
<strong>Supplies</strong> <strong>for</strong> Agilent 1100 Series<br />
Description Part No. Autosampler Pump DAD/VWD<br />
Tool Kit<br />
includes:<br />
5064-8211<br />
Rheotool socket wrench 8710-2391<br />
Hex key, 4.0 mm, T-h<strong>and</strong>le 8710-2392<br />
Hex key, 3.0 mm, straight h<strong>and</strong>le 8710-2411<br />
Hex key, 2.5 mm, straight h<strong>and</strong>le 8710-2412<br />
Hex key, 1.5 mm, straight h<strong>and</strong>le 8710-2393<br />
Hex key, 9/64”, T-h<strong>and</strong>le 8710-2394<br />
Description Part No.<br />
Online degasser accessory kit<br />
includes: 8 screws, 8 bushings, 4 markers, tubing, syringe, adapter<br />
G1322-68705<br />
Tubing kit (from degasser to pump) (4/pk) G1322-67300<br />
Glass filter, solvent inlet 5041-2168<br />
Parts <strong>for</strong> 1100 Micro vacuum degasser<br />
Description Part No.<br />
Dual-channel micro degasser vacuum chamber G1379-60001<br />
Vaccum tube set G1379-67300<br />
Mounting tool <strong>for</strong> degasser screws 0100-1710<br />
Parts <strong>for</strong> 1100 Pump modules<br />
Description Part No.<br />
Maintenance kit G1311-68710<br />
includes: outlet cap (1), PTFE frits (10), piston seals (4),<br />
gold seal, outlet (1), cartridge <strong>for</strong> active inlet valve (1), inlet filter (2)<br />
Piston seal, teflon/graphite (2/pk) 5063-6589<br />
Piston seal <strong>for</strong> NP (Hexane) applications <strong>for</strong> isocratic <strong>and</strong> quaternary pumps 0905-1420<br />
Sapphire plunger 5063-6586<br />
Seal wash kit 01018-68722<br />
5063-6586 / 5063-6589<br />
5041-2168
Parts <strong>for</strong> 1100 Pump modules<br />
Description Part No.<br />
Maintenance kit G1311-68710<br />
includes: outlet cap (1), PTFE frits (10), piston seals (4),<br />
gold seal, outlet (1), cartridge <strong>for</strong> active inlet valve (1), inlet filter (2)<br />
Frit adapter, 3 mm (4/pk) 5062-8517<br />
Glass filter, solvent inlet, 20 µm pore size 5041-2168<br />
Solvent reservoir, 1 liter 9301-1420<br />
Solvent reservoir, 1 liter with cap 9301-1421<br />
Solvent reservoir, amber, 1 liter 9301-1450<br />
Bottle cap with 3-hole insert 5063-6531<br />
Solvent tubing, 5m, 1.5 mm id, 3 mm od 5062-2483<br />
Parts <strong>for</strong> 1100 Capillary pump<br />
Description Part No.<br />
Acessory kit <strong>for</strong> capillary pump G1376-68705<br />
Filter assy with 0.5 µm pore size filter 5064-8273<br />
replacement frits 0.5 µm <strong>for</strong> 5064-8273, 10/pk 5022-2185<br />
Torque adapter G1315-45003<br />
Bottle head assy G1376-60003<br />
Parts <strong>for</strong> autosampler<br />
Description Part No.<br />
Maintenance kit G1313-68709<br />
includes: 1 rotor seal (Vespel), 1 needle, 1 needle seat,<br />
2 metering seals, 15 finger caps<br />
Rotor seal (Vespel) 0100-1853<br />
Rotor seal (Tefzel) 0100-1849<br />
Finger caps (15/pk) 5063-6506<br />
Tray <strong>for</strong> 100 2-ml vials G1313-44500<br />
Tray <strong>for</strong> 40 2-ml vials G1313-44502<br />
Tray <strong>for</strong> 15 6-ml vials G1313-44503<br />
Multi-draw upgrade kit<br />
includes: 1 seat capillary, 500 µl, 1 seat capillary 1500 µl, ZDV union<br />
G1313-68711<br />
9301-1420 / 9301-1450 / 9301-1421<br />
G1313-68709<br />
5063-6531<br />
45
46<br />
<strong>Supplies</strong> <strong>for</strong> Agilent 1100 Series<br />
Parts <strong>for</strong> 1100 Micro autosampler<br />
Description Part No.<br />
Accessory kit <strong>for</strong> µ-LC auto sampler G1329-68715<br />
Injection valve <strong>for</strong> 1100 µ-LC 0101-1050<br />
Rotor seal, Vespel, 2 grooves <strong>for</strong> µ-LC system 0100-2088<br />
Stator <strong>for</strong> µ-LC valves 0100-2089<br />
6 fittings, 2 plugs, PEEK, <strong>for</strong> µ-LC valves 5065-4410<br />
Sapphire plunger assy, 2 mm 5064-8293<br />
Plunger seal, 2 mm 5022-2175<br />
Seal support assy G1377-60002<br />
Seat assy <strong>for</strong> µ-LC autosampler G1329-87101<br />
Needle <strong>for</strong> µ-LC autosampler G1329-80001<br />
Parts <strong>for</strong> 1100 Well plate sampler<br />
Description Part No.<br />
Accessory kit <strong>for</strong> well plate sampler G1367-68705<br />
Needle assy G1367-87200<br />
Seat assy MTP G1367-87101<br />
Loop capillary assy G1367-87300<br />
Peristaltic pump 5042-6401<br />
Tray <strong>for</strong> well plate sampler G1367-60001<br />
Well plates <strong>for</strong> well plate sampler<br />
Description Part No.<br />
96 well plates, 0.5 ml, PP, 120/pk 5042-1385<br />
96 well plates, 0.5 ml, PP, 10/pk 5042-1386<br />
96 deep well plates, 1 ml, PP, 32/pk 5042-1387<br />
384 well plates, PP, 30/pk 5042-1388<br />
96 well plates with glass inserts, caps <strong>and</strong> septa pre-assembled. 0.35 ml 5065-4402<br />
closing mats <strong>for</strong> 96 well plates 5042-1389<br />
Parts <strong>for</strong> 1100 Thermostatted column compartment<br />
Description Part No.<br />
Column identification module (3/pk) 5062-8588<br />
Column clamp (6/pk) 5063-6526<br />
Temperature calibration kit, includes 1 spring clamp <strong>and</strong> 30 thermal pads G1316-68707
Parts <strong>for</strong> Capillary LC applications<br />
Description Part No.<br />
Column switching valve <strong>for</strong> µ-LC system 0101-1051<br />
Rotor seal, Vespel, 3 grooves <strong>for</strong> µ-LC system – column switching 0100-2087<br />
Stator <strong>for</strong> µ-LC valves 0100-2089<br />
Column holder <strong>for</strong> µ-LC columns 5001-3702<br />
Parts <strong>for</strong> 1100 Diode array detector<br />
Description Part No.<br />
Long-life deuterium lamp, shinethrough 5181-1530<br />
Deuterium lamp, shine through 2140-0590<br />
Tungsten lamp G1103-60001<br />
St<strong>and</strong>ard flow cell, 10 mm, 13 µl,120 bar G1315-60012<br />
Cell repair kit <strong>for</strong> st<strong>and</strong>ard flow cell<br />
includes: 12 front seals, 12 back seals, window screw kit, hex key 6 mm<br />
G1315-68712<br />
Semi-micro flow cell, 6 mm, 5 µl, 120 bar G1315-60011<br />
Cell repair kit <strong>for</strong> semi-micro flow cell<br />
includes: 12 front seals, 12 back seals, window screw kit, hex key 6 mm<br />
G1315-68713<br />
500 nl flow cell kit, 10 mm, 50 bar G1315-68714<br />
High pressure micro flow cell, 6 mm, 1.7 µl, 400 bar G1315-60015<br />
High-pressure cell kit<br />
includes: 1 window, 5 washers, 2 seals<br />
79883-68700<br />
Parts <strong>for</strong> 1100 Variable wavelength detector<br />
Description Part No.<br />
Deuterium lamp G1314-60100<br />
St<strong>and</strong>ard flow cell, 10 mm, 14 µl, 40 bar G1314-60080<br />
St<strong>and</strong>ard flow cell kit<br />
includes: 2 windows, 2 gaskets #1, 2 gaskets #2<br />
G1314-65050<br />
Semi-micro flow cell, 6 mm, 5 µl, 40 bar G1314-60083<br />
Micro flow cell, 5 mm, 1 µl, 40 bar G1314-60081<br />
Micro flow cell kit<br />
includes: 2 windows, 2 gaskets #1, 2 gaskets #2<br />
G1314-65052<br />
High pressure flow cell, 10 mm, 14 µl, 400 bar G1314-60082<br />
High pressure flow cell kit<br />
includes: 2 windows, 2 KAPTON gaskets, 2 PEEK rings<br />
G1314-65054<br />
OQ/PV test sample 8500-6762<br />
5181-1530<br />
47
48<br />
<strong>Supplies</strong> <strong>for</strong> Agilent 1100 Series<br />
Connecting capillaries <strong>for</strong> the 1100 Capillary LC System<br />
Generic connecting capillaries <strong>for</strong> cap-LC system<br />
Pos From To Fitting Part No.<br />
1 SSV AIV G1311-67304<br />
2 Piston 1 Piston 2 A/A G1312-67300<br />
3 Pump Restriction capillary A/A G1312-67302<br />
4 Mixing capillary Damper A/A G1312-67304<br />
5 Damper Mixer A/A 01090-87308<br />
5 Mixer Filter A/A 01090-87308<br />
6 Filter EMPV A/A G1375-87400<br />
7 Needle seat Injection valve -/C G1329-87101<br />
SSV<br />
Pumphead A Pumphead B<br />
h<br />
g<br />
1 1<br />
2 2<br />
3 3<br />
Flow cell<br />
Waste<br />
Damper<br />
4<br />
Column<br />
e<br />
f<br />
Mixer<br />
5<br />
Waste<br />
Filter<br />
5 6<br />
c<br />
Injection valve<br />
b<br />
7<br />
EMPV<br />
Metering<br />
device<br />
a<br />
Flow<br />
sensor<br />
d<br />
Needle
Connecting capillaries <strong>for</strong> the 1100 Capillary LC System<br />
PEEK coated fused silica capillaries <strong>for</strong> use with 20 µl/min flow range<br />
Pos From To Fitting ID [µm] Part No.<br />
a EMPV Flowsensor B/B 50 G1375-87301<br />
b Flowsensor Injection valve B/C 50 G1375-87310<br />
c Injection valve Metering device B/C 50 G1375-87302<br />
d Metering device Needle B/B 100 G1375-87303<br />
e Injection valve Column C/D 50 G1375-87304<br />
f Injection valve Waste C/- 100 G1375-87307<br />
g Column Detector D/E 50 G1315-68703<br />
h Detector Waste E/- 75 G1315-68708<br />
µ-switching valve Column C/D 50 G1375-87309<br />
PEEK coated fused silica capillaries <strong>for</strong> use with 100 µl/min flow range<br />
Pos From To Fitting ID [µm] Part No.<br />
a EMPV Flowsensor B/B 100 G1375-87305<br />
b Flowsensor Injection valve B/C 100 G1375-87306<br />
c Injection valve Metering device B/C 100 G1375-87312<br />
d Metering device Needle B/B 100 G1375-87303<br />
e Injection valve Column C/D 75 G1375-87311<br />
f Injection valve Waste C/- 100 G1375-87307<br />
g Column Detector D/E 75 G1375-87308<br />
h Detector Waste E/- 75 G1315-68708<br />
µ-switching valve Column C/D 50 G1375-87309<br />
Capillaries come with fittings as listed above<br />
Replacement fittings <strong>and</strong> ferrules<br />
Description Type Part No.<br />
1/16" fittings, front <strong>and</strong> back ferrules 10/pk A 5062-2418<br />
M4/16" fittings, 10/pk B 5063-6593<br />
1/32" ferrule <strong>and</strong> SS lock ring, 10/pk B 5065-4423<br />
6 Fittings, 2 plugs, PEEK <strong>for</strong> µ-valves C 5065-4410<br />
Double winged nuts <strong>and</strong> 1/32" ferrules, 10/pk D 5065-4422<br />
5062-2418<br />
5063-6593<br />
5065-4423<br />
5065-4410<br />
5065-4422<br />
49
50<br />
Parts <strong>for</strong> pump module<br />
<strong>Supplies</strong> <strong>for</strong> Agilent 1050 Series<br />
Description Part No.<br />
Maintenance kit including: 01018-68724<br />
5 outlet caps, 10 PTFE frits, 4 piston seals, 5 gold seals outlet,<br />
cartridge <strong>for</strong> active inlet valve<br />
Sapphire plunger 5063-6586<br />
Piston Seal (2/pk) 5063-6589<br />
Cartridge <strong>for</strong> active inlet valve 5062-8562<br />
Outlet caps (4/pk) 5062-2485<br />
Outlet gold seal 5001-3707<br />
Teflon frits (5/pk) 01018-22707<br />
Seal wash kit including: 01018-68722<br />
film washers, wear retainer, tool, tubing,<br />
seals, strap, clamp, rings, syringe<br />
Solvent reservoir, 1 liter 9301-0656<br />
Solvent tubing (5 m) 5062-2483<br />
Helium tubing (5 m) 5062-2461<br />
Polyethylene actuator air tubing (12 ft) 5021-7127<br />
Solvent inlet filter assembly 01018-82701<br />
Parts <strong>for</strong> manual injector<br />
Description Part No.<br />
Rotor seal (tefzel) (up to pH 12.5) 0101-0620<br />
Rotor seal (vespel) 0101-0623<br />
Sample loop 10 µl 0101-0376<br />
Sample loop 20 µl 0101-0377<br />
Sample loop 50 µl 0101-0378<br />
Sample loop 100 µl 0101-0379<br />
Solvent inlet filter, stainless steel 01018-60025<br />
Helium sparge assembly 01019-82702<br />
Glass filter, helium (10–16 µm pore size) 5041-8339<br />
Connector <strong>for</strong> helium sparger (6/pk) 5062-8515<br />
01018-68724<br />
5063-6586 / 5063-6589<br />
01018-82701
Parts <strong>for</strong> autosampler<br />
Description Part No.<br />
Maintenance kit including: 01078-68721<br />
2 needle seats, 2 needles, 1 seat capillary, 1 rotor seal<br />
Exp<strong>and</strong>ed injection volume kit including: 01078-68704<br />
500 µl seat capillary, 2 ml seat capillary, flush union<br />
Rotor seal (Vespel) 0101-0626<br />
Rotor seal (Tefzel) (up to pH 12.5) 0101-0627<br />
Needle assembly 01078-67200<br />
Needle seat 79846-67101<br />
Seat capillary 01078-87303<br />
Piston seal (2/pk) 5063-6589<br />
Parts <strong>for</strong> variable wavelength detector<br />
Description Part No.<br />
Deuterium lamp 79853-60002<br />
Microflow cell 79853-60010<br />
High-pressure flow cell 79853-60013<br />
Parts <strong>for</strong> diode array detector<br />
Description Part No.<br />
St<strong>and</strong>ard cell repair kit containing: 79883-68701<br />
2 windows, 10 washers,<br />
2 window holders, 2 window screws<br />
Deuterium lamp 79883-60002<br />
01078-68721<br />
79883-60002<br />
51
52<br />
General parts<br />
<strong>Supplies</strong> <strong>for</strong> Agilent 1090 Series<br />
Description Part No.<br />
Polyethylene actuator air tubing 1/4 in od (12 ft) 5021-7127<br />
Teflon general purpose tubing 1/8 in od (12 ft) 5021-7113<br />
St<strong>and</strong>ard accessory kit including:<br />
hexagonal key set, wrenches, Pozidrives, syringe, tubing<br />
01090-68721<br />
Parts <strong>for</strong> solvent delivery system<br />
Description Part No.<br />
Solvent reservoir, 1 liter 9301-0656<br />
Check valve cartridge 79835-67101<br />
Check valve cartridge (up to pH 12.5) 79835-67102<br />
Replacement sieve <strong>for</strong> check valve cartridge 79835-65213<br />
Replacement sieve <strong>for</strong> check valve cartridge (up to pH 12.5) 79835-65216<br />
Piston seals (4/pk) 5062-2494<br />
Piston seal <strong>for</strong> use with buffered solvents 0905-1194<br />
Sapphire plunger 3980-0672<br />
Diaphragm 79835-04123<br />
Solvent inlet filter 01090-60008<br />
Glass frit <strong>for</strong> helium sparging (10–16 µm pore size) 5041-8339<br />
Helium sparge assembly 01019-82702<br />
Solvent capillary 01090-87606<br />
Parts <strong>for</strong> electrochemical detector<br />
Description Part No.<br />
Glassy carbon electrode 01049-64105<br />
Platinium working electrode 01049-28801<br />
Gold working electrode 01049-28802<br />
Polishing kit 01049-67001<br />
KCl electrolyte 01049-92101<br />
01090-60008<br />
5062-2494
Parts <strong>for</strong> detectors<br />
Description Part No.<br />
Deuterium lamp <strong>for</strong> filter photometric detector 79880-60002<br />
Deuterium lamp <strong>for</strong> diode array detector 79883-60002<br />
Spare parts kit <strong>for</strong> filter photometric detector 79881-68701<br />
containing: Springs, gaskets, windows, capillary, tweezers, wrench<br />
Filter kit <strong>for</strong> filter photometric detector 79881-62760<br />
Filter 210 nm, 230 nm, 280 nm, 340 nm, 430 nm, 540 nm<br />
Xenon arc flash lamp <strong>for</strong> fluorescence detector 2140-0549<br />
Spare part kit <strong>for</strong> fluorescence detector<br />
containing: gaskets, step windows, rings, springs, tweezers<br />
01046-68702<br />
Lamp <strong>for</strong> RI detector 01037-60002<br />
Parts <strong>for</strong> variable volume injector<br />
Description Part No.<br />
Spare part kit <strong>for</strong> variable volume injector containing: 79846-68702<br />
syringe seals, syringe plunger, rotor seal, needle<br />
inserts, needle seats, seat capillary<br />
Rotor seal (Vespel) 1535-4048<br />
Rotor seal (Tefzel) (up to pH 12.5) 1535-4900<br />
250 µl syringe upgrade kit 79846-68701<br />
The kit contains the necessary parts to convert the<br />
maximum injection volume from 25 µl to 250 µl.<br />
Sample loops <strong>for</strong> 7010/7125 Rheodyne valve<br />
Description Part No.<br />
Loop, 5 µl 1535-4860<br />
Loop, 10 µl 0101-0376<br />
Loop, 20 µl 0101-0377<br />
Loop, 50 µl 0101-0378<br />
Loop, 100 µl 0101-0379<br />
79883-60008<br />
53
54<br />
Environmental<br />
<strong>HPLC</strong> application literature<br />
Agilent Technologies research<br />
<strong>and</strong> application chemists have<br />
created a broad range of<br />
application notes <strong>for</strong> many<br />
application areas. Use the free of<br />
charge application notes <strong>and</strong><br />
benefit from our experience.<br />
Take a look at our application<br />
notes <strong>and</strong> application briefs on<br />
the Worldwide Web at:<br />
www.agilent.com/chem<br />
Title Publication no.<br />
Development of an LC/MS Method <strong>for</strong> the Analysis of Rodenticides Application 5980-0561E<br />
Detection of Low Levels of Carbaryl in Food Using Agilent LC/MSD Ion Trap System Application 5980-0332E<br />
Separation <strong>and</strong> Analysis of Toxic Arsenic Species Using LC-ICP-MS Application 5980-0262E<br />
LC/DAD/MS Analysis of Carbonyl (2,-4Dinitrophenyl) hydrazones Application 5968-8850E<br />
LC/MS Analysis of Microcystins in Freshwater by Electrospray Ionization Application 5968-2123E<br />
Analysis of Fumonisin Mycotoxins by LC/MS Application 5968-2124E<br />
<strong>HPLC</strong> analysis of <strong>for</strong>maldehyde in indoor air Application 5967-5598E<br />
Analysis of Bendiocarb <strong>and</strong> Metabolite by <strong>HPLC</strong> Application 5966-1876E<br />
Analysis of Paraquat <strong>and</strong> Diquat by <strong>HPLC</strong> Application 5966-1875E<br />
Analysis of ionic tenside surfactants in wastewater by <strong>HPLC</strong> Application 5966-1877E<br />
Gel Permeation Chromatography <strong>for</strong> Clean-up of Soil <strong>and</strong> Sediments using <strong>HPLC</strong> Application 5966-1873E<br />
Analysis of Formaldehyde <strong>and</strong> Acetaldehyde Application 5965-9796E<br />
Gradient LC analysis of herbicides <strong>and</strong> polyaromatic hydrocarbons by isocratic<br />
Capillary Electrochromatography Application 5965-9032E<br />
Improved Data Quality in the Automated <strong>HPLC</strong> Analysis of PNAs (PAHs) Application 5964-3540E<br />
Polynuclear Aromatic Hydrocarbons by <strong>HPLC</strong> Application 5091-7260E<br />
<strong>HPLC</strong> Analysis of Explosive Constituents in Soil Samples Application 5091-7626E<br />
A Comparison of Pre- <strong>and</strong> Post-Column Sample Treatment <strong>for</strong> the Analysis of Glyphosate Application 5091-3621E
Pharmaceutical<br />
Title Publication no.<br />
High throughput screening of a peptide library with the Agilent 1100 Series<br />
combinatorial chemistry analysis system Application 5968-8661E<br />
Quality Control of Pharmaceutical Drugs-Turning Analysis <strong>and</strong> Per<strong>for</strong>mance Data into Comprehensible Charts Application 5968-7570E<br />
Agilent CombiZorb Scavengers Application 5968-7832E<br />
Isolation <strong>and</strong> characterization of natural products using the Agilent 220 micro plate sampler with the<br />
Agilent 1100 Series <strong>HPLC</strong> system Application 5968-6252E<br />
Automatic <strong>HPLC</strong> analysis of indometacin in plasma using column switching Application 5968-7205E<br />
Spectral analysis of peptides <strong>and</strong> proteins using diode-array detection <strong>for</strong> important structural in<strong>for</strong>mation Application 5968-6294E<br />
Quality control of recombinant peptide <strong>and</strong> protein drugs by capillary <strong>HPLC</strong> Application 5968-6251E<br />
Purity check of proteins by capillary <strong>HPLC</strong>-DAD-MS Application 5968-6197E<br />
The best wavelength <strong>for</strong> detection of peptide maps Application 5968-6196E<br />
Capillary <strong>HPLC</strong> separation of 2D in-gel digested protein spots from proteome projects Application 5968-6195E<br />
Simple reversed-phase purification of human Erythropoietin (EPO) from fully <strong>for</strong>mulated drugs Application 5968-6194E<br />
Rapid Desalting of Protein Samples on Very Short Reversed-phase <strong>Columns</strong> Application 5968-4712E<br />
Identification of Pyridylethylated Cysteine Residues in Peptide Maps Using Diode-array Detection Application 5968-4739E<br />
Analysis of Glucocorticoids by <strong>HPLC</strong> Application 5968-2967E<br />
Analysis of Catecholamines by <strong>HPLC</strong> Application 5968-2966E<br />
Analysis of Antitumor Drugs by <strong>HPLC</strong> Application 5968-2886E<br />
Analysis of Antihypertensive Drugs by <strong>HPLC</strong> Application 5968-2887E<br />
Analysis of Antihistaminic Drugs by <strong>HPLC</strong> Application 5968-2889E<br />
55
56<br />
Pharmaceutical<br />
<strong>HPLC</strong> application literature<br />
Title Publication no.<br />
Analysis of Antidepressant Drugs by <strong>HPLC</strong> Application 5968-2963E<br />
Analysis of Androgen Drugs by <strong>HPLC</strong> Application 5968-2964E<br />
Analysis of Analgesic Drugs by <strong>HPLC</strong> Application 5968-2965E<br />
Analysis of Rhein <strong>and</strong> Emodin in Rhubarb Root Extract (Rheum palmatum) by <strong>HPLC</strong> Application 5968-2972E<br />
Analysis of Ephedrine <strong>and</strong> Norephedrine in Ephedra Sinica Stapf with <strong>HPLC</strong> Application 5968-2884E<br />
Analysis of Protocatechuic Acid, Protocatechuic Aldehyde <strong>and</strong> Tanshinones in Dan Shen Pills by <strong>HPLC</strong> Application 5968-2882E<br />
Analysis of Water-Soluble Vitamins by <strong>HPLC</strong> Application 5968-2971E<br />
Analysis of Fat-Soluble Vitamins by <strong>HPLC</strong> Application 5968-2970E<br />
Analysis of Tricyclic Antidepressant Drugs by <strong>HPLC</strong> Application 5968-2969E<br />
Analysis of Hypnotic Drugs by <strong>HPLC</strong> Application 5968-2968E<br />
Analysis of Quercetin <strong>and</strong> Kaempferol in Gingko Extract <strong>and</strong> Tablets (Gingko Biloba) by <strong>HPLC</strong> Application 5968-2973E<br />
Analysis of Quinine <strong>and</strong> Quinidine in Cinchona Bark Extract (Cortex Cinchonae) by <strong>HPLC</strong> Application 5968-2974E<br />
Analysis of Atropine in Belladonna Extract (Atropa Belladonna) by <strong>HPLC</strong> Application 5968-2975E<br />
Identifying Toxins Using an Extensive, Fast <strong>and</strong> Automated <strong>HPLC</strong> Spectral Library Application 5968-2596E<br />
Analysis of Antiepileptic Drugs by <strong>HPLC</strong> Application 5968-1119E<br />
of Antiestrogen Drugs by <strong>HPLC</strong> Application 5968-1118E<br />
Analysis of Antiinflammatory Drugs by <strong>HPLC</strong> Application 5968-1117E<br />
Analysis of Antiprotozoal Drugs by <strong>HPLC</strong> Application 5968-1116E
Pharmaceutical<br />
Title Publication no.<br />
Analysis of Antitussive Drugs by <strong>HPLC</strong> Application 5968-1115E<br />
Analysis of H2-Antagonist Drugs by <strong>HPLC</strong> Application 5968-1114E<br />
Analysis of Keratolytica by <strong>HPLC</strong> Application 5968-1113E<br />
Analysis of Antianginal Drugs by <strong>HPLC</strong> Application 5968-1081E<br />
Analysis of Anticoagulant Drugs by <strong>HPLC</strong> Application 5968-1082E<br />
Analysis of Muscle-relaxing Drugs by <strong>HPLC</strong> Application 5968-1112E<br />
Analysis of Sulfa Drugs with <strong>HPLC</strong> Application 5968-1111E<br />
Analysis of Therapeutic Peptides by <strong>HPLC</strong> Application 5968-1109E<br />
Analysis of Antiarrythmic Drugsby <strong>HPLC</strong> Application 5968-1080E<br />
Analysis of Antiasthmatic Drugs by <strong>HPLC</strong> Application 5968-1079E<br />
Analysis of Antibacterial Drugs by <strong>HPLC</strong> Application 5968-1078E<br />
Analysis of Sedative Drugs with <strong>HPLC</strong> Application 5968-1110E<br />
Analysis of testosterone metabolites using <strong>HPLC</strong> Application 5967-5596E<br />
Transfer of <strong>HPLC</strong> methods to Capillary Electrochromatography Application 5965-9031E<br />
Analysis of Steroid Isomers by Capillary Electrochromatography Application 5965-9030E<br />
Qualitative & Quantitative Analysis of Dyes with <strong>HPLC</strong> Diode-Array Detection Application 5964-3559E<br />
Separation <strong>and</strong> Isolation of Hydrophobic Peptides Using <strong>HPLC</strong> 5965-7507E<br />
ZORBAX GF-250 <strong>and</strong> GF-450 Size-Exclusion (Gel Filtration) <strong>Columns</strong> 5966-2063E<br />
Rapid, Accurate, Sensitive, <strong>and</strong> Reproducible <strong>HPLC</strong> Analysis of Amino Acids 5980-1193E<br />
57
58<br />
Food <strong>and</strong> Flavors<br />
<strong>HPLC</strong> application literature<br />
Title Publication no.<br />
Development of an LC/MS Method <strong>for</strong> the Analysis of Rodenticides Application 5980-0561E<br />
Rapid Determination of Vitamin D3 in Poultry Feed Supplements Application 5968-9408E<br />
Analysis of Flavonoids in Plant Extracts by CE-MS Application 5968-5729E<br />
Analysis of Natural Food Colorants By Electrospray <strong>and</strong> Atmospheric Pressure Chemical Ionization LC/MS Application 5968-2979E<br />
Analysis of Fumonisin Mycotoxins by LC/MS Application 5968-2124E<br />
The Analysis of Triglycerides in Edible Oils by APCI LC/MS Application 5968-0878E<br />
Analysis of tetracyclines by <strong>HPLC</strong> Application 5966-1619E<br />
Analysis of sugars in foods <strong>and</strong> beverages by <strong>HPLC</strong> with pulsed amperometric detector Application 5965-9797E<br />
Analysis of Bitter Compounds, in Orange Juice using <strong>HPLC</strong> Application 5966-0631E<br />
Analysis of Triglycerides in Olive Oil <strong>and</strong> Rap Oil using <strong>HPLC</strong> Application 5966-0634E<br />
Analysis of Amino Acids in Beer using <strong>HPLC</strong> with Online Derivatization Application 5966-0746E<br />
Analysis of Anions in Drinking Water using <strong>HPLC</strong> Application 5966-0633E<br />
Analysis of Fat Soluble Vitamins using <strong>HPLC</strong> Application 5966-0745E<br />
Analysis of Unsaturated Triglycerides using <strong>HPLC</strong> Application 5966-0744E<br />
Analysis of Glyphosate in Water with Postcolumn Derivatization using <strong>HPLC</strong> Application 5966-0743E<br />
Analysis of Pesticides in Salad Samples <strong>and</strong> Spices using <strong>HPLC</strong> Application 5966-0742E<br />
Analysis of aspartame using <strong>HPLC</strong> Application 5966-0741E<br />
<strong>HPLC</strong> Analysis of Vitamins in Tablets using <strong>HPLC</strong> Application 5966-0639E<br />
Normal Phase Analysis of Tocopherols in Margarine using <strong>HPLC</strong> Application 5966-0641E<br />
Analysis of Antioxidants in Chewing Gum using <strong>HPLC</strong> Application 5966-0628E
Food <strong>and</strong> Flavors<br />
Title Publication no.<br />
Analysis of Carbohydrates in Lemonade using <strong>HPLC</strong> Application 5966-0637E<br />
Analysis of Hydrolized Fatty Acids in Dietary Fat using <strong>HPLC</strong> Application 5966-0635E<br />
Analysis of Vanillin Extract Quality using <strong>HPLC</strong> Application 5966-0630E<br />
<strong>HPLC</strong> Analysis of Aflatoxines in Pistachio Nuts using <strong>HPLC</strong> Application 5966-0632E<br />
Analysis of Preservatives in White Wine <strong>and</strong> Salad Dressing using <strong>HPLC</strong> Application 5966-0629E<br />
Analysis of Acidulants in White Wine using <strong>HPLC</strong> Application 5966-0627E<br />
Analysis of catechins in tea by <strong>HPLC</strong> with electrochemical detector Application 5965-9802E<br />
of Amino Acids in Seasonings by Automated Pre-Column Derivatization <strong>HPLC</strong> Application 5965-9795E<br />
Analysis of Residual Synthetic Antibacterials in Meat by <strong>HPLC</strong> Application 5965-9794E<br />
& Quantitative Analysis of Dyes with <strong>HPLC</strong> Diode-Array Detection Application 5964-3559E<br />
Desalting of Oligonucleotides <strong>for</strong> Electrospray Mass Spectrometry Application 5964-2332E<br />
Analysis of Mycotoxins by <strong>HPLC</strong> with Automated Confirmation by Spectral Library Application 5091-8692<br />
Computer-Aided Development of a Normal-Phase <strong>HPLC</strong> Separation of Tocopherols <strong>and</strong><br />
Tocotrienols in Vegetable Oil Application 5091-5302E<br />
Computer-Aided Development of a Reversed-Phase <strong>HPLC</strong> Separation of Acids in Coffee Application 5091-5324E<br />
Analysis of Selected Vitamins with <strong>HPLC</strong> <strong>and</strong> Electrochemical Detection Application 5091-3194E<br />
Analysis of Selected Anions with <strong>HPLC</strong> <strong>and</strong> Electrochemical Detection Application 5091-1815E<br />
59
60<br />
Basic <strong>HPLC</strong> troubleshooting<br />
Symptom Possible Cause Solution(s)<br />
Baseline disturbance Positive/negative–Difference in Use mobile phase <strong>for</strong> sample solvent<br />
at void time refractive index of injection solvent<br />
Detector leaks Catastrophic–Failed detector seal Replace seals/gaskets<br />
Drifting baseline Positive direction–Contaminant<br />
buildup/elution<br />
Flush column, cleanup sample, use pure solvents<br />
Negative direction (gradient)–<br />
Absorbance of ”A“ mobile phase solvent<br />
Use non-absorbing or <strong>HPLC</strong>-grade solvent<br />
Positive direction (gradient)–<br />
Absorbance of mobile phase ”B“<br />
Use higher UV wavelength<br />
Positive direction (gradient)–<br />
Absorbance of ”B“ mobile phase solvent<br />
Use non-absorbing or <strong>HPLC</strong>-grade solvents<br />
R<strong>and</strong>om–Temperature changes Insulate column <strong>and</strong> tubing<br />
R<strong>and</strong>om–Temperature changes Thermostat column <strong>and</strong> tubing<br />
Wavy or undulating–Temperature<br />
changes in room<br />
Monitor room temperature <strong>and</strong> control<br />
Ghost peaks Peaks from previous injection Flush column at end of run with strong solvent<br />
Contamination Flush column to remove contaminants<br />
Unknown interferences in samples Sample cleanup or pre-fractionation<br />
lon pair–Upset equilibrium Prepare sample in actual mobile phase to minimize<br />
disturbance<br />
Peptide mapping–Oxidation of TFA Prepare fresh daily; use anti-oxidant<br />
Reversed phase–Contaminated water Check suitability of water by running different<br />
amounts through reversed phase column <strong>and</strong><br />
measure peak height with elution; use <strong>HPLC</strong> grade<br />
Spikes–Bubbles in solvent De-gas solvents<br />
High column Column blockage with irrev. adsorbed Better sample cleanup; use guard column<br />
backpressure sample<br />
Too high mobile phase viscosity Use lower viscosity solvents or higher temperature<br />
Particle size too small Use larger dp packing<br />
Plugged inlet frit Replace end fitting<br />
Plugged inlet frit Reverse solvent flow<br />
Leak Subtle; white powder at fitting–<br />
Loose fitting<br />
Tighten fitting, cut tubing, or replace ferrule<br />
Leak, injection valve Catastrophic–Worn valve rotor Replace rotor in valve<br />
Leak, column or other<br />
fittings<br />
Catastrophic–Loose fittings Tighten or replace fitting<br />
Leak, pump Catastrophic–Pump seal failure Replace pump seal
Symptom Possible Cause Solution(s)<br />
Negative peaks RI detector–solute refractive index less<br />
than solvent<br />
No problem; reverse polarity to make positive<br />
UV detector–solute absorbance less Use mobile phase with lower UV absorbance; do not<br />
than mobile phase recycle solvent too long<br />
Noisy baseline R<strong>and</strong>om–Contaminant buildup Flush column; cleanup sample; use <strong>HPLC</strong>-grade<br />
solvents<br />
Continuous–Detector lamp problem Replace UV lamp (lasts 1000 hrs)<br />
Occasional–External electrical<br />
interference<br />
Use voltage stabilizer <strong>for</strong> LC system<br />
Spikes–Bubble in detector De-gas mobile phase or back pressure regulator<br />
Peak doubling Sample volume too large Injection volume should be 1/6 when mobile phase<br />
used <strong>for</strong> injection<br />
Injection solvent too strong Use weaker injection solvent or mobile phase<br />
Blocked frit Replace <strong>and</strong> use 0.5 µm porosity in-line filter<br />
Column void or channeling Fill in void with glass beads or packing; repack column<br />
Unswept injector flowpath Replace injector rotor<br />
Void at head of column Top off column with packing or glass beads<br />
Column overloaded with sample Use higher capacity stationary phase<br />
Column overloaded with sample Increase column diameter<br />
Column overloaded with sample Decrease sample size<br />
Single peak–Interfering components Sample cleanup; prefractionation<br />
Peak tailing Beginning of peak doubling See peak doubling<br />
Unswept dead volumes Minimize number of connections<br />
Unswept dead volumes Ensure injector seal is tight<br />
Unswept dead volumes Ensure fittings are properly seated<br />
Basic compounds–Silanol interaction Switch to polymeric phase<br />
Basic substances–Silanol interactions Use stronger mobile phase or add competiting base<br />
(e.g. TMA)<br />
Silica-based–Column degradation Use speciality column; polymeric column, or sterically<br />
protected<br />
Silica-based–Silanol interaction Add salt to mobile phase to increase buffer<br />
concentration<br />
Silica-based–Silanol interaction Lower mobile phase pH to suppress silanol ionization<br />
Silica-based–Silanol interaction Derivatize solute to change polar interactions<br />
61
62<br />
Basic <strong>HPLC</strong> troubleshooting<br />
Symptom Possible Cause Solution(s)<br />
Peaks are broad Injection volume too large Decrease solvent strength of injection solvent to<br />
focus solute<br />
Peak dispersion in injector valve Introduce air bubble in front/back of sample to<br />
decrease dispersion<br />
Sampling rate of data system too slow Increase frequency of sampling<br />
Slow detector time constant Adjust time constant to match peak width<br />
Mobile phase viscosity too high Increase column temperature<br />
Detector cell volume too large Use smallest possible cell volume with no heat<br />
exchanger in system<br />
Injector volume too large Decrease injection volume<br />
Long retention times Use gradient elution or stronger mobile phase<br />
Large extra-column volumes Use low-dead volume end fittings <strong>and</strong> connectors<br />
Peaks are broad Large extra-column volumes Minimize connecting tubing diameters<br />
Poor column efficiency Use smaller dp particle<br />
Early eluting–Sample overload Dilute sample 1:10 <strong>and</strong> re-inject<br />
Poor sample recovery Adsorption on column packing Strengthen mobile phase to minimize adsorption<br />
Absorption of proteins Change <strong>HPLC</strong> mode to cut down on nonspecific<br />
interactions<br />
Adsorption on tubing or other hardware Use inert tubing (PEEK), glass-lined or titanium tubing<br />
components or components<br />
Chemisorption on packing material Ensure no reactive groups; change column type or mode<br />
Pressure decreasing Leaky check valve Replace check valve<br />
Pump cavitation De-gas solvents<br />
Insufficient flow to column Unblock line prior to pump<br />
Insufficient flow Mobile phase reservoir too tightly sealed; loosen cap<br />
Pressure fluctuation Leaky check valve Replace check valve<br />
Bubble in pump De-gas, helium sparge<br />
Pump seal leaks Replace pump seals<br />
Pressure increasing Buildup of particulates Filter sample; in-line filter; filter mobile phase<br />
Water/organic systems – Buffer<br />
precipitation<br />
Test buffer – organic mixtures; ensure compatibility<br />
Retention beyond total Size exclusion – Specific interactions Add mobile phase modifiers or change solvent to cut<br />
permeation volume with stationary phase down on<br />
Retention times are Column temperature varying Thermostat column; insulate column; ensure lab temp<br />
changing constant
Symptom Possible Cause Solution(s)<br />
Retention times are Equilibration time insufficient with gradient Make sure at least 10 column volumes pass through<br />
changing run or changes in isocratic mobile phase column after solvent change or gradient conclusion<br />
Selective evaporation of mobile phase Less vigorous helium sparging; keep solvent<br />
component reservoirs covered; prepare fresh mobile phase<br />
Buffer capacity insufficient Use >20 mM concentration of buffer<br />
Inconsistent on-line mobile phase mixing Ensure gradient system delivering constant<br />
composition; check vs. manual prep of mobile phase<br />
Contamination buildup Flush column occasionally to remove contaminants<br />
First few injections–Adsorption on Condition column by initial injection of concentrated<br />
active sites sample<br />
Retention times are Flow rate increasing Check pump to make sure flow rate correct;<br />
decreasing reset if not<br />
Column overloaded with sample Decrease sample size<br />
Loss of bonded stationary phase Keep mobile phase pH between 2 <strong>and</strong> 8.5<br />
Retention times are Flow rate is slowing Fix leaks in liquid lines, replace pump seals, check <strong>for</strong><br />
increasing pump cavitation or air bubbles<br />
Active sites on silica packing Use mobile phase modifier<br />
Loss of bonded stationary phase Keep pH of mobile phase in 2 to 8.5 range<br />
Mobile phase composition changing Make sure mobile phase container is covered<br />
Active sites on silica packing Add competing base to mobile phase<br />
Active sites on silica packing Use higher coverage packing <strong>for</strong> stationary phase<br />
Sensitivity problem Peaks are outside of linear range of<br />
detector<br />
Dilute/concentrate to bring into linear region<br />
First few sample injections–Adsorption<br />
of sample in loop or column<br />
Condition loop/column with concentrated sample<br />
Sensitivity problem Autosampler flow lines blocked Check flow <strong>and</strong> make sure no blockages<br />
Injector sample loop under filled Make sure that loop is over filled with sample<br />
Sample-related losses during Use internal st<strong>and</strong>ard during sample prep; optimize<br />
preparation sample prep method<br />
Short column lifetime Silica-based–Degradation by mobile<br />
phase<br />
Use polymer-based packing<br />
Silica-based–Degradation by mobile<br />
phase<br />
Keep pH between 2 <strong>and</strong> 8.5<br />
Silica-based–Mobile phase pH too high Keep pH in 2 to 8.5 range<br />
Slow column Equilibration time slow <strong>for</strong> long-chain Use shorter alkyl chain reagent<br />
equilibration times ion pairing reagents<br />
(ion pairing)<br />
63
For greater confidence in your<br />
<strong>HPLC</strong> results, you can optimize<br />
your total system with quality<br />
Agilent columns <strong>and</strong> supplies –<br />
the perfect fit with your Agilent<br />
instrument.<br />
A full line of <strong>HPLC</strong> columns,<br />
cartridges <strong>and</strong> supplies are<br />
designed, manufactured <strong>and</strong><br />
tested to rigorous Agilent<br />
specifications, under a quality<br />
system registered to ISO 9001. So<br />
why risk compromising your<br />
analytical results with anything<br />
less than genuine Agilent<br />
consumables?<br />
A perfect fit with your LC also<br />
reduces the risk of system<br />
failures, <strong>and</strong> loss of productivity.<br />
Plus Agilent’s service, support<br />
<strong>and</strong> applications expertise can<br />
help you get up <strong>and</strong> running<br />
faster. Order today from Agilent<br />
Analytical Direct, from our<br />
authorized distributors worldwide,<br />
or via the Internet:<br />
www.agilent.com/chemsupplies<br />
For more in<strong>for</strong>mation on our<br />
products <strong>and</strong> services, visit our<br />
worldwide web site at<br />
www.agilent.com/chemsupplies<br />
The in<strong>for</strong>mation in this publication is<br />
subject to change without notice.<br />
© Copyright Agilent Technologies 2000<br />
Printed in Germany November 30, 2000<br />
Publication Number 5988-0535EN