26 | V-net _Central Controller<br />

Central Controller_V-net | 27<br />

AHU Kit [Control Kit]<br />

AHU have functions like cooling, heating, humidification, Air cleaning &ventilation ;<br />

providing Multi-solution to the consumer.<br />

PRCKD20E<br />

PRCKD40E<br />

1.4 SYSTEM LAYOUT<br />

AHU Kit [Expansion Kit]<br />

AHU have functions like cooling, heating, humidification, Air cleaning &ventilation ;<br />

providing Multi-solution to the consumer.<br />

PATX13A0E<br />

PATX20A0E<br />

PATX25A0E<br />

PATX35A0E<br />

SPECIFICATION SPECIFICATION<br />

Control Kit<br />

Model Name<br />

PRCKD20E<br />

PRCKD40E<br />

Temp. Senor / RA, SA(essential),<br />

Mix(optional)<br />

Temp. & Humid. Sensor/<br />

RA, SA, OA(optional)<br />

Damper Actuator /<br />

EA, OA, Mix(optional)<br />

Differential Pressure<br />

switch (optional)<br />

Valve for<br />

Humidifier (optional)<br />

CO2 Senor<br />

(optional)<br />

Smoke Detector<br />

(optional)<br />

Fan/ Supply, Return<br />

Weight(kg) Dimension(mm)<br />

NET Gross W H D<br />

43.5 48 600 750 285 220~240V, 50/ 60Hz, 1Ph<br />

Air<br />

Handling<br />

Unit<br />

Wired Remote Controller<br />

Control kit<br />

Local Control Kit<br />

POWER Model Feature<br />

Expansion Kit<br />

• AHU Controller<br />

• ODU Comm. PCB<br />

• Sensor Power Supply<br />

1~4 Set ODU Combine<br />

5~8 Set ODU Combine<br />

Interconnection Pipe<br />

Communication wire<br />

Thermistor (Pipe Temp.)<br />

Signal (On / Off)<br />

Signal (DC0 ~ 10V)<br />

Expansion Kit<br />

Model Name<br />

PATX13A0E<br />

PATX20A0E<br />

PATX25A0E<br />

PATX35A0E<br />

1.4 SYSTEM LAYOUT<br />

Temp. Senor / RA, SA(essential),<br />

Mix(optional)<br />

Temp. & Humid. Sensor/<br />

RA, SA, OA(optional)<br />

Damper Actuator /<br />

EA, OA, Mix(optional)<br />

Differential Pressure<br />

switch (optional)<br />

Valve for<br />

Humidifier (optional)<br />

CO2 Senor<br />

(optional)<br />

Smoke Detector<br />

(optional)<br />

Fan/ Supply, Return<br />

Weight(kg) Dimension(mm)<br />

NET Gross W H D<br />

5.6<br />

6.9<br />

5.8<br />

6.0<br />

7.1<br />

7.3<br />

238 169 491<br />

6.2<br />

7.5<br />

Air<br />

Handling<br />

Unit<br />

Wired Remote Controller<br />

Control kit<br />

Local Control Kit<br />

Expansion Kit<br />

Model Feature<br />

• ODU Capacity : 8~16HP<br />

• ODU Capacity : 18~26HP<br />

• ODU Capacity : 28~36HP<br />

• ODU Capacity : 38~42HP<br />

Interconnection Pipe<br />

Communication wire<br />

Thermistor (Pipe Temp.)<br />

Signal (On / Off)<br />

Signal (DC0 ~ 10V)