General data<br />

Maximum inlet pressure<br />

The following table shows the maximum permissible<br />

inlet pressure. However, the actual inlet pressure + the<br />

pressure against a closed valve must always be lower<br />

than the maximum permissible operating pressure.<br />

<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1 psi /bar<br />

1-2 ➝ 1-4<br />

1-5 ➝ 1-25<br />

1-27<br />

<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 3<br />

3-2<br />

3-3 ➝ 3-15<br />

3-17 ➝ 3-25<br />

<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 5<br />

5-2 ➝ 5-8<br />

5-9 ➝ 5-24<br />

<strong>CR</strong>, <strong>CR</strong>X, <strong>CR</strong>N 8<br />

8-20/1 ➝ 8-40<br />

8-50 ➝ 8-160<br />

<strong>CR</strong>, <strong>CR</strong>X, <strong>CR</strong>N 16<br />

16-30/2 ➝ 16-30<br />

16-40 ➝ 16-120<br />

<strong>CR</strong>, <strong>CR</strong>N 32<br />

32-1-1 ➝ 32-1<br />

32-2-2 ➝ 32-2<br />

32-3 ➝ 32-5<br />

32-6 ➝ 11-2<br />

<strong>CR</strong>, <strong>CR</strong>N 45<br />

45-1-1 ➝ 45-1<br />

45-2-2 ➝ 45-3<br />

45-4-2 ➝ 8-1<br />

<strong>CR</strong>, <strong>CR</strong>N 64<br />

64-1-1<br />

64-1 ➝ 64-2-1<br />

64-2 ➝ 64-5-2<br />

<strong>CR</strong>, <strong>CR</strong>N 90<br />

90-1-1 ➝ 90-1<br />

90-2-2 ➝ 90-4-2<br />

87 /6<br />

145/10<br />

217/15<br />

87 /6<br />

145/10<br />

217/15<br />

145/10<br />

217/15<br />

87 /6<br />

145/10<br />

87 /6<br />

145/10<br />

43/3<br />

58/4<br />

145/10<br />

217/15<br />

58/4<br />

145/10<br />

217/15<br />

58/4<br />

145/10<br />

217/15<br />

145/10<br />

217/15<br />

Vertical multistage centrifugal pumps<br />

Example of operating <strong>and</strong> inlet pressures<br />

The values for operating <strong>and</strong> inlet pressures shown<br />

in the tables must not be considered individually but<br />

must always be compared, see the following examples:<br />

Example 1:<br />

The following pump type has been selected:<br />

<strong>CR</strong> 3-10 U-A-A<br />

Max. operating pressure: 232 psi (16 bar)<br />

Max. inlet pressure: 145 psi (10 bar)<br />

Discharge pressure against a closed valve: 139 psi<br />

(9.6 bar), see page 32.<br />

This pump is not allowed to start at an inlet pressure of<br />

145 psi (10 bar), but on the other h<strong>and</strong> at an inlet pressure<br />

of 232 psi less 139 psi = 93 psi (16.0 less 9.6 = 6.4<br />

bar).<br />

Example 2:<br />

The following pump type has been selected:<br />

<strong>CR</strong> 3-2 U-A-A<br />

Max. operating pressure: 232 psi (16 bar)<br />

Max. inlet pressure: 87 psi (6 bar)<br />

Discharge pressure against a closed valve: 27 psi<br />

(1.9 bar), see page 32.<br />

This pump is allowed to start at an inlet pressure of 87<br />

psi (6 bar), as the discharge pressure against a closed<br />

valve is only 27 psi (1.9 bar), which results in an operating<br />

pressure of 87 psi + 27 psi = 114 psi (6.0 + 1.9 = 7.9 bar).<br />

On the contrary, the max. operating pressure of this<br />

pump is limited to 144 psi (7.9 bar), as a higher operating<br />

pressure will require an inlet pressure of more than 87<br />

psi (6 bar).<br />

In case the inlet or operating pressure exceeds the pressure<br />

permitted, see Custom-built <strong>Pump</strong>s, page 80.