LBE flow rate [kg/s]<br />
• Analysis by RELAP5/Mod3.3 system<br />
code to characterize the<br />
performance of a wire spaced fuel<br />
bundle relevant for MYRRHA facility<br />
(i.e. heat exchange and pressure<br />
drop) in shutdown conditions and<br />
providing data for code validation.<br />
• First application, to a simplified<br />
representation of NACIE facility, of<br />
the coupling between the RELAP5<br />
thermal-hydraulic system code and<br />
the CFD Fluent commercial code<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
0<br />
RELAP+Fluent<br />
RELAP<br />
0 200 400 600 800 1000<br />
Time [s]<br />
Thermal-Hydraulic<br />
Pre-test analysis of thermal-hydraulic<br />
behaviour of the NACIE facility for the<br />
characterization of a fuel pin bundle<br />
7.5 m<br />
Tmdpjun<br />
615<br />
TDPVOL<br />
699<br />
686 0.3 m<br />
TDPVOL<br />
610<br />
3.9 m<br />
0.8 m<br />
J-185<br />
K=0.5<br />
J-203<br />
1<br />
8<br />
0<br />
HX2<br />
186<br />
HX1<br />
J-207<br />
1<br />
9<br />
0<br />
2<br />
0<br />
0<br />
2<br />
0<br />
6<br />
J-183<br />
k=1<br />
J-187<br />
170<br />
J-157<br />
K=2.2<br />
210<br />
160<br />
1.25 m<br />
1.0 m<br />
TDPVOL<br />
320<br />
Br 150<br />
An.<br />
152<br />
P<br />
148<br />
An. P<br />
156 146<br />
Pipe<br />
120<br />
Reference cell<br />
for pressure data needed<br />
for Fluent outlet b.c.<br />
Reference junction<br />
for flowrate data needed<br />
for inlet Fluent b.c.<br />
1<br />
3<br />
0<br />
125<br />
TDPVOL<br />
112<br />
TDPVOL<br />
110<br />
Pipe<br />
100<br />
Tmdpjun<br />
405<br />
J-105<br />
J-215<br />
Expansion<br />
Vessel<br />
Tmdpjun<br />
115<br />
0.765 m<br />
Part of the nodalization of the primary loop<br />
used for RELAP5 code in the coupled simulations<br />
TDPVOL<br />
(Ar)<br />
410<br />
0.05 m<br />
1.25 m<br />
Reference cell<br />
for temperaure data<br />
needed for inlet Fluent b.c.<br />
Reference section<br />
for flowrate and<br />
temperaure data needed<br />
for RELAP5 inlet b.c.<br />
1.3 m<br />
Reference section<br />
for pressure data needed<br />
for RELAP5 outlet b.c.<br />
Pipe used for Fluent code<br />